Cargando…

Biodegradable polymer-coated thin strut sirolimus-eluting stent versus durable polymer-coated everolimus-eluting stent in the diabetic population

BACKGROUND: The number of patients with diabetes mellitus (DM) presenting with coronary artery disease is increasing and accounts for more than 30% of patients undergoing percutaneous coronary interventions (PCI). The biodegradable polymer drug-eluting stents were developed to improve vascular heali...

Descripción completa

Detalles Bibliográficos
Autores principales: Gasior, Pawel, Gierlotka, Marek, Szczurek-Katanski, Krzysztof, Osuch, Marcin, Roleder, Magda, Hawranek, Michal, Wojakowski, Wojciech, Polonski, Lech
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Via Medica 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8078944/
https://www.ncbi.nlm.nih.gov/pubmed/31909473
http://dx.doi.org/10.5603/CJ.a2019.0111
Descripción
Sumario:BACKGROUND: The number of patients with diabetes mellitus (DM) presenting with coronary artery disease is increasing and accounts for more than 30% of patients undergoing percutaneous coronary interventions (PCI). The biodegradable polymer drug-eluting stents were developed to improve vascular healing. It was sought herein, to determine 1-year clinical follow-up in patients with DM treated with the thin strut biodegradable polymer-coated sirolimus-eluting stent (BP-SES) versus durable coating everolimus-eluting stent (DP-EES). METHODS: Patients were retrospectively analyzed with DM were treated with either a BP-SES (ALEX™, Balton, Poland, n = 670) or a DP-EES (XIENCE™, Abbott, USA, n = 884) with available 1 year clinical follow-up using propensity score matching. Outcomes included target vessel revascularization (TVR) as efficacy outcome and all-cause death, myocardial infarction, and definite/probable stent thrombosis as safety outcomes. RESULTS: After propensity score matching 527 patients treated with BP-SES and 527 patients treated with DP-EES were selected. Procedural and clinical characteristics were similar between both groups. In-hospital mortality was 3.23% in BP-SES vs. 2.09% in DP-EES group (p = 0.25). One-year follow-up demonstrated comparable efficacy outcome TVR (BP-SES 6.64% vs. DP-EES 5.88%; p = 0.611), as well as similar safety outcomes of all-cause death (BP-SES 10.06% vs. DP-EES 7.59%; p = 0.158), myocardial infarction (BP-SES 7.959% vs. DP-EES 6.83%; p = 0.813), and definite/probable stent thrombosis (BP-SES 1.14% vs. DP-EES 0.76%; p = 0.525). CONCLUSIONS: The thin-strut biodegradable polymer coated, sirolimus-eluting stent demonstrated comparable clinical outcomes at 1-year after implantation to DP-EES. These data support the relative safety and efficacy of BP-SES in diabetic patients undergoing PCI.