Activity of Deposited Lysozyme on Contemporary Soft Contact Lenses Exposed to Differing Lens Care Systems
PURPOSE: The amount of protein deposition on soft contact lenses and to what extent the proteins are denatured may have an impact on comfortable wearing times of contact lenses. The purpose of this study was to evaluate the effects of two lens care systems on total protein and the quantity and activ...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8079347/ https://www.ncbi.nlm.nih.gov/pubmed/33935489 http://dx.doi.org/10.2147/OPTH.S296116 |
_version_ | 1783685208856330240 |
---|---|
author | Heynen, Miriam Ng, Alan Martell, Elizabeth Subbaraman, Lakshman N Jones, Lyndon |
author_facet | Heynen, Miriam Ng, Alan Martell, Elizabeth Subbaraman, Lakshman N Jones, Lyndon |
author_sort | Heynen, Miriam |
collection | PubMed |
description | PURPOSE: The amount of protein deposition on soft contact lenses and to what extent the proteins are denatured may have an impact on comfortable wearing times of contact lenses. The purpose of this study was to evaluate the effects of two lens care systems on total protein and the quantity and activity of lysozyme deposited on worn senofilcon A, silicone hydrogel contact lenses. PARTICIPANTS AND METHODS: Thirty symptomatic soft contact lens wearers were enrolled into a 4-week prospective, randomized, bilateral eye, daily-wear, crossover, double-masked study. Participants were fitted with biweekly senofilcon A lenses and were assigned either a polyquaternium-1 and myristamidopropyl dimethylamine-containing system (OPTI-FREE RepleniSH) or a peroxide-based system (CLEAR CARE). After each wear period, proteins were extracted from the lenses and analyzed for total protein, total lysozyme quantity and activity. RESULTS: The use of either the peroxide-based system or the polyquaternium-1 and myristamidopropyl dimethylamine-containing system resulted in no difference (P>0.05) to the amount of total protein deposited on the lenses (6.7 ± 2.8 micrograms/lens versus 7.3 ± 2.8 micrograms/lens, respectively) or to the amount of denatured lysozyme deposits (0.8 ± 0.7 versus 0.9 ± 0.7 micrograms/lens), respectively. The total amount of lysozyme deposited on the lenses was significantly lower when using the peroxide-based system (1.3 ± 0.9 micrograms/lens) compared to the polyquaternium-1 and myristamidopropyl dimethylamine-containing system (1.7 ± 1.0 micrograms/lens) (P=0.02). CONCLUSION: The inactivation of lysozyme deposited on senofilcon A lenses when disinfected with the peroxide-based or the polyquaternium-1 and myristamidopropyl dimethylamine-containing systems were neither statistically nor clinically significant and the overall amounts of denatured lysozyme recovered from the lenses were low (<1 microgram/lens). |
format | Online Article Text |
id | pubmed-8079347 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-80793472021-04-29 Activity of Deposited Lysozyme on Contemporary Soft Contact Lenses Exposed to Differing Lens Care Systems Heynen, Miriam Ng, Alan Martell, Elizabeth Subbaraman, Lakshman N Jones, Lyndon Clin Ophthalmol Original Research PURPOSE: The amount of protein deposition on soft contact lenses and to what extent the proteins are denatured may have an impact on comfortable wearing times of contact lenses. The purpose of this study was to evaluate the effects of two lens care systems on total protein and the quantity and activity of lysozyme deposited on worn senofilcon A, silicone hydrogel contact lenses. PARTICIPANTS AND METHODS: Thirty symptomatic soft contact lens wearers were enrolled into a 4-week prospective, randomized, bilateral eye, daily-wear, crossover, double-masked study. Participants were fitted with biweekly senofilcon A lenses and were assigned either a polyquaternium-1 and myristamidopropyl dimethylamine-containing system (OPTI-FREE RepleniSH) or a peroxide-based system (CLEAR CARE). After each wear period, proteins were extracted from the lenses and analyzed for total protein, total lysozyme quantity and activity. RESULTS: The use of either the peroxide-based system or the polyquaternium-1 and myristamidopropyl dimethylamine-containing system resulted in no difference (P>0.05) to the amount of total protein deposited on the lenses (6.7 ± 2.8 micrograms/lens versus 7.3 ± 2.8 micrograms/lens, respectively) or to the amount of denatured lysozyme deposits (0.8 ± 0.7 versus 0.9 ± 0.7 micrograms/lens), respectively. The total amount of lysozyme deposited on the lenses was significantly lower when using the peroxide-based system (1.3 ± 0.9 micrograms/lens) compared to the polyquaternium-1 and myristamidopropyl dimethylamine-containing system (1.7 ± 1.0 micrograms/lens) (P=0.02). CONCLUSION: The inactivation of lysozyme deposited on senofilcon A lenses when disinfected with the peroxide-based or the polyquaternium-1 and myristamidopropyl dimethylamine-containing systems were neither statistically nor clinically significant and the overall amounts of denatured lysozyme recovered from the lenses were low (<1 microgram/lens). Dove 2021-04-23 /pmc/articles/PMC8079347/ /pubmed/33935489 http://dx.doi.org/10.2147/OPTH.S296116 Text en © 2021 Heynen et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Original Research Heynen, Miriam Ng, Alan Martell, Elizabeth Subbaraman, Lakshman N Jones, Lyndon Activity of Deposited Lysozyme on Contemporary Soft Contact Lenses Exposed to Differing Lens Care Systems |
title | Activity of Deposited Lysozyme on Contemporary Soft Contact Lenses Exposed to Differing Lens Care Systems |
title_full | Activity of Deposited Lysozyme on Contemporary Soft Contact Lenses Exposed to Differing Lens Care Systems |
title_fullStr | Activity of Deposited Lysozyme on Contemporary Soft Contact Lenses Exposed to Differing Lens Care Systems |
title_full_unstemmed | Activity of Deposited Lysozyme on Contemporary Soft Contact Lenses Exposed to Differing Lens Care Systems |
title_short | Activity of Deposited Lysozyme on Contemporary Soft Contact Lenses Exposed to Differing Lens Care Systems |
title_sort | activity of deposited lysozyme on contemporary soft contact lenses exposed to differing lens care systems |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8079347/ https://www.ncbi.nlm.nih.gov/pubmed/33935489 http://dx.doi.org/10.2147/OPTH.S296116 |
work_keys_str_mv | AT heynenmiriam activityofdepositedlysozymeoncontemporarysoftcontactlensesexposedtodifferinglenscaresystems AT ngalan activityofdepositedlysozymeoncontemporarysoftcontactlensesexposedtodifferinglenscaresystems AT martellelizabeth activityofdepositedlysozymeoncontemporarysoftcontactlensesexposedtodifferinglenscaresystems AT subbaramanlakshmann activityofdepositedlysozymeoncontemporarysoftcontactlensesexposedtodifferinglenscaresystems AT joneslyndon activityofdepositedlysozymeoncontemporarysoftcontactlensesexposedtodifferinglenscaresystems |