Cargando…
Quantitative Evaluation of Aerosol Generation from Non-contact Tonometry and its Correlation with Tear Film Characteristics
INTRODUCTION: Ophthalmologists are inevitably exposed to tears and ocular discharge during ophthalmologic examinations and are at high risk for SARS-CoV-2 infection. To understand the role of aerosols in disease transmission, we adopted a prospective cross-sectional study design and investigated the...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Healthcare
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8080094/ https://www.ncbi.nlm.nih.gov/pubmed/33909233 http://dx.doi.org/10.1007/s12325-021-01740-8 |
_version_ | 1783685358543699968 |
---|---|
author | Hao, Weiting Wu, Jianhui Zhao, Xinheng Liang, Danni Yu, Xingchen Cao, Huazheng Wang, Yan |
author_facet | Hao, Weiting Wu, Jianhui Zhao, Xinheng Liang, Danni Yu, Xingchen Cao, Huazheng Wang, Yan |
author_sort | Hao, Weiting |
collection | PubMed |
description | INTRODUCTION: Ophthalmologists are inevitably exposed to tears and ocular discharge during ophthalmologic examinations and are at high risk for SARS-CoV-2 infection. To understand the role of aerosols in disease transmission, we adopted a prospective cross-sectional study design and investigated the count and size distribution of aerosols generated by a non-contact tonometer and its correlation with individual tear film characteristics. METHODS: This study constituted two parts. The study population included outpatients who underwent an intraocular pressure examination in an intraocular pressure examination room (Part I) and 20 participants who underwent an intraocular pressure examination in a laboratory (Part II). The following main outcomes were measured: aerosol counts at 0, 50, 100, 150, and 200 cm from the non-contact tonometer (Part I); aerosol counts after each participant underwent non-contact tonometry, and lipid layer thickness score and tear film break-up time (Part II). RESULTS: The aerosol count decreased with increasing distance from the tonometer. The aerosol count at 0 cm had the highest value compared to that at other distances. For aerosols of diameters 0.25–0.5 μm and 0.5–1.0 μm, the count decreased at 50 cm and remained stable at further distances. For aerosols of diameters 1.0–2.5 μm and ≥ 2.5 μm, the count dropped progressively at all five distances. The aerosol count from each tonometer correlated positively with the lipid layer thickness score (r = 0.490, P = 0.028), whereas the aerosol count correlated negatively with the tear film break-up time (r = − 0.675, P = 0.001). CONCLUSIONS: Aerosols tended to coagulate during diffusion. A 50-cm distance from the tonometer could confer safety from aerosols with < 1.0-μm diameter. Aerosols generated during non-contact tonometry could contain a lipid layer component. Moreover, tear film stability could affect aerosol generation. Protective eyewear is recommended for reducing infection risk from aerosols. Individual tear film characteristics should be considered during non-contact tonometry. |
format | Online Article Text |
id | pubmed-8080094 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer Healthcare |
record_format | MEDLINE/PubMed |
spelling | pubmed-80800942021-04-28 Quantitative Evaluation of Aerosol Generation from Non-contact Tonometry and its Correlation with Tear Film Characteristics Hao, Weiting Wu, Jianhui Zhao, Xinheng Liang, Danni Yu, Xingchen Cao, Huazheng Wang, Yan Adv Ther Original Research INTRODUCTION: Ophthalmologists are inevitably exposed to tears and ocular discharge during ophthalmologic examinations and are at high risk for SARS-CoV-2 infection. To understand the role of aerosols in disease transmission, we adopted a prospective cross-sectional study design and investigated the count and size distribution of aerosols generated by a non-contact tonometer and its correlation with individual tear film characteristics. METHODS: This study constituted two parts. The study population included outpatients who underwent an intraocular pressure examination in an intraocular pressure examination room (Part I) and 20 participants who underwent an intraocular pressure examination in a laboratory (Part II). The following main outcomes were measured: aerosol counts at 0, 50, 100, 150, and 200 cm from the non-contact tonometer (Part I); aerosol counts after each participant underwent non-contact tonometry, and lipid layer thickness score and tear film break-up time (Part II). RESULTS: The aerosol count decreased with increasing distance from the tonometer. The aerosol count at 0 cm had the highest value compared to that at other distances. For aerosols of diameters 0.25–0.5 μm and 0.5–1.0 μm, the count decreased at 50 cm and remained stable at further distances. For aerosols of diameters 1.0–2.5 μm and ≥ 2.5 μm, the count dropped progressively at all five distances. The aerosol count from each tonometer correlated positively with the lipid layer thickness score (r = 0.490, P = 0.028), whereas the aerosol count correlated negatively with the tear film break-up time (r = − 0.675, P = 0.001). CONCLUSIONS: Aerosols tended to coagulate during diffusion. A 50-cm distance from the tonometer could confer safety from aerosols with < 1.0-μm diameter. Aerosols generated during non-contact tonometry could contain a lipid layer component. Moreover, tear film stability could affect aerosol generation. Protective eyewear is recommended for reducing infection risk from aerosols. Individual tear film characteristics should be considered during non-contact tonometry. Springer Healthcare 2021-04-28 2021 /pmc/articles/PMC8080094/ /pubmed/33909233 http://dx.doi.org/10.1007/s12325-021-01740-8 Text en © The Author(s), under exclusive licence to Springer Healthcare Ltd., part of Springer Nature 2021 This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic. |
spellingShingle | Original Research Hao, Weiting Wu, Jianhui Zhao, Xinheng Liang, Danni Yu, Xingchen Cao, Huazheng Wang, Yan Quantitative Evaluation of Aerosol Generation from Non-contact Tonometry and its Correlation with Tear Film Characteristics |
title | Quantitative Evaluation of Aerosol Generation from Non-contact Tonometry and its Correlation with Tear Film Characteristics |
title_full | Quantitative Evaluation of Aerosol Generation from Non-contact Tonometry and its Correlation with Tear Film Characteristics |
title_fullStr | Quantitative Evaluation of Aerosol Generation from Non-contact Tonometry and its Correlation with Tear Film Characteristics |
title_full_unstemmed | Quantitative Evaluation of Aerosol Generation from Non-contact Tonometry and its Correlation with Tear Film Characteristics |
title_short | Quantitative Evaluation of Aerosol Generation from Non-contact Tonometry and its Correlation with Tear Film Characteristics |
title_sort | quantitative evaluation of aerosol generation from non-contact tonometry and its correlation with tear film characteristics |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8080094/ https://www.ncbi.nlm.nih.gov/pubmed/33909233 http://dx.doi.org/10.1007/s12325-021-01740-8 |
work_keys_str_mv | AT haoweiting quantitativeevaluationofaerosolgenerationfromnoncontacttonometryanditscorrelationwithtearfilmcharacteristics AT wujianhui quantitativeevaluationofaerosolgenerationfromnoncontacttonometryanditscorrelationwithtearfilmcharacteristics AT zhaoxinheng quantitativeevaluationofaerosolgenerationfromnoncontacttonometryanditscorrelationwithtearfilmcharacteristics AT liangdanni quantitativeevaluationofaerosolgenerationfromnoncontacttonometryanditscorrelationwithtearfilmcharacteristics AT yuxingchen quantitativeevaluationofaerosolgenerationfromnoncontacttonometryanditscorrelationwithtearfilmcharacteristics AT caohuazheng quantitativeevaluationofaerosolgenerationfromnoncontacttonometryanditscorrelationwithtearfilmcharacteristics AT wangyan quantitativeevaluationofaerosolgenerationfromnoncontacttonometryanditscorrelationwithtearfilmcharacteristics |