Cargando…

Surgical retrieval of broken, inflated angioplasty balloon catheter within intracoronary stent: A real emergency

A 54-year old, hypertensive female patient underwent percutaneous coronary angioplasty (PTCA) followed by stenting of calcified chronic totally occluded right coronary artery. The post dilation balloon catheter got stuck and snapped during manipulations in inflated position within the stent, which c...

Descripción completa

Detalles Bibliográficos
Autores principales: Waikar, Hemant Digambar, Desilva, Rajitha, Rathnayake, Wasanthi, Ponnamperuma, Chandrika, Ravikiran, Anthonpillai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8081146/
https://www.ncbi.nlm.nih.gov/pubmed/33938848
http://dx.doi.org/10.4103/aca.ACA_2_20
_version_ 1783685578294820864
author Waikar, Hemant Digambar
Desilva, Rajitha
Rathnayake, Wasanthi
Ponnamperuma, Chandrika
Ravikiran, Anthonpillai
author_facet Waikar, Hemant Digambar
Desilva, Rajitha
Rathnayake, Wasanthi
Ponnamperuma, Chandrika
Ravikiran, Anthonpillai
author_sort Waikar, Hemant Digambar
collection PubMed
description A 54-year old, hypertensive female patient underwent percutaneous coronary angioplasty (PTCA) followed by stenting of calcified chronic totally occluded right coronary artery. The post dilation balloon catheter got stuck and snapped during manipulations in inflated position within the stent, which could not be retrieved by nonsurgical interventions. Emergency surgery was performed to retrieve the stent along with an inflated balloon, followed by vein patch closure of arteriotomy and reversed saphenous vein graft anastomosis to right coronary artery and left anterior descending artery on cardiopulmonary bypass.
format Online
Article
Text
id pubmed-8081146
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-80811462021-06-02 Surgical retrieval of broken, inflated angioplasty balloon catheter within intracoronary stent: A real emergency Waikar, Hemant Digambar Desilva, Rajitha Rathnayake, Wasanthi Ponnamperuma, Chandrika Ravikiran, Anthonpillai Ann Card Anaesth Case Report A 54-year old, hypertensive female patient underwent percutaneous coronary angioplasty (PTCA) followed by stenting of calcified chronic totally occluded right coronary artery. The post dilation balloon catheter got stuck and snapped during manipulations in inflated position within the stent, which could not be retrieved by nonsurgical interventions. Emergency surgery was performed to retrieve the stent along with an inflated balloon, followed by vein patch closure of arteriotomy and reversed saphenous vein graft anastomosis to right coronary artery and left anterior descending artery on cardiopulmonary bypass. Wolters Kluwer - Medknow 2021 2021-01-22 /pmc/articles/PMC8081146/ /pubmed/33938848 http://dx.doi.org/10.4103/aca.ACA_2_20 Text en Copyright: © 2021 Annals of Cardiac Anaesthesia https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Case Report
Waikar, Hemant Digambar
Desilva, Rajitha
Rathnayake, Wasanthi
Ponnamperuma, Chandrika
Ravikiran, Anthonpillai
Surgical retrieval of broken, inflated angioplasty balloon catheter within intracoronary stent: A real emergency
title Surgical retrieval of broken, inflated angioplasty balloon catheter within intracoronary stent: A real emergency
title_full Surgical retrieval of broken, inflated angioplasty balloon catheter within intracoronary stent: A real emergency
title_fullStr Surgical retrieval of broken, inflated angioplasty balloon catheter within intracoronary stent: A real emergency
title_full_unstemmed Surgical retrieval of broken, inflated angioplasty balloon catheter within intracoronary stent: A real emergency
title_short Surgical retrieval of broken, inflated angioplasty balloon catheter within intracoronary stent: A real emergency
title_sort surgical retrieval of broken, inflated angioplasty balloon catheter within intracoronary stent: a real emergency
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8081146/
https://www.ncbi.nlm.nih.gov/pubmed/33938848
http://dx.doi.org/10.4103/aca.ACA_2_20
work_keys_str_mv AT waikarhemantdigambar surgicalretrievalofbrokeninflatedangioplastyballooncatheterwithinintracoronarystentarealemergency
AT desilvarajitha surgicalretrievalofbrokeninflatedangioplastyballooncatheterwithinintracoronarystentarealemergency
AT rathnayakewasanthi surgicalretrievalofbrokeninflatedangioplastyballooncatheterwithinintracoronarystentarealemergency
AT ponnamperumachandrika surgicalretrievalofbrokeninflatedangioplastyballooncatheterwithinintracoronarystentarealemergency
AT ravikirananthonpillai surgicalretrievalofbrokeninflatedangioplastyballooncatheterwithinintracoronarystentarealemergency