Cargando…

Presence of Atrial Fibrillation in Stroke Patients With Patent Foramen Ovale: Systematic Review and Meta-Analysis

Purpose: Patent foramen ovale (PFO) is associated with ischemic stroke, especially in patients with embolic stroke of undetermined source. This study aims to evaluate the presence of atrial fibrillation (AF) in ischemic stroke patients with PFO. Methods: We systematically searched EMBASE and MEDLINE...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Jessie Ze-Jun, Thijs, Vincent N.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8081982/
https://www.ncbi.nlm.nih.gov/pubmed/33935933
http://dx.doi.org/10.3389/fneur.2021.613758
_version_ 1783685753200443392
author Chen, Jessie Ze-Jun
Thijs, Vincent N.
author_facet Chen, Jessie Ze-Jun
Thijs, Vincent N.
author_sort Chen, Jessie Ze-Jun
collection PubMed
description Purpose: Patent foramen ovale (PFO) is associated with ischemic stroke, especially in patients with embolic stroke of undetermined source. This study aims to evaluate the presence of atrial fibrillation (AF) in ischemic stroke patients with PFO. Methods: We systematically searched EMBASE and MEDLINE databases on May 21, 2020 for studies that analyzed the presence of AF in patients with PFO. The primary outcome was the presence of AF in patients with PFO compared with those without. Outcomes were pooled using a random-effects model using the method of DerSimonian and Laird. We recorded demographic characteristics and the methods used for AF detection in the studies included (unspecified, history/medical records review, ECG, Holter monitor, or loop recorder). Results: A total of 14 studies and 13,245 patients fulfilled the entry criteria. The average age was 61.2 years and 41.3% of the participants were female. There was a lower risk of AF in patients with PFO compared with those without (RR 0.52, 95% confidence interval, 0.41–0.63, p < 0.001). There was no evidence of heterogeneity. The lower risk of AF was found in cross-sectional and longitudinal studies and in studies stratified by average age (<60 or ≥60) and in cryptogenic stroke. Meta-regression by PFO detection technique suggested that studies using transoesophageal echocardiogram for PFO detection reported higher risk of AF (1.39, 95% confidence interval 1.14–1.70, p = 0.004). Conclusion: The presence of a PFO in patients with ischemic stroke/TIA may be associated with a lower risk of AF. Few studies have estimated the risk of future AF in patients with PFO.
format Online
Article
Text
id pubmed-8081982
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-80819822021-04-30 Presence of Atrial Fibrillation in Stroke Patients With Patent Foramen Ovale: Systematic Review and Meta-Analysis Chen, Jessie Ze-Jun Thijs, Vincent N. Front Neurol Neurology Purpose: Patent foramen ovale (PFO) is associated with ischemic stroke, especially in patients with embolic stroke of undetermined source. This study aims to evaluate the presence of atrial fibrillation (AF) in ischemic stroke patients with PFO. Methods: We systematically searched EMBASE and MEDLINE databases on May 21, 2020 for studies that analyzed the presence of AF in patients with PFO. The primary outcome was the presence of AF in patients with PFO compared with those without. Outcomes were pooled using a random-effects model using the method of DerSimonian and Laird. We recorded demographic characteristics and the methods used for AF detection in the studies included (unspecified, history/medical records review, ECG, Holter monitor, or loop recorder). Results: A total of 14 studies and 13,245 patients fulfilled the entry criteria. The average age was 61.2 years and 41.3% of the participants were female. There was a lower risk of AF in patients with PFO compared with those without (RR 0.52, 95% confidence interval, 0.41–0.63, p < 0.001). There was no evidence of heterogeneity. The lower risk of AF was found in cross-sectional and longitudinal studies and in studies stratified by average age (<60 or ≥60) and in cryptogenic stroke. Meta-regression by PFO detection technique suggested that studies using transoesophageal echocardiogram for PFO detection reported higher risk of AF (1.39, 95% confidence interval 1.14–1.70, p = 0.004). Conclusion: The presence of a PFO in patients with ischemic stroke/TIA may be associated with a lower risk of AF. Few studies have estimated the risk of future AF in patients with PFO. Frontiers Media S.A. 2021-04-15 /pmc/articles/PMC8081982/ /pubmed/33935933 http://dx.doi.org/10.3389/fneur.2021.613758 Text en Copyright © 2021 Chen and Thijs. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neurology
Chen, Jessie Ze-Jun
Thijs, Vincent N.
Presence of Atrial Fibrillation in Stroke Patients With Patent Foramen Ovale: Systematic Review and Meta-Analysis
title Presence of Atrial Fibrillation in Stroke Patients With Patent Foramen Ovale: Systematic Review and Meta-Analysis
title_full Presence of Atrial Fibrillation in Stroke Patients With Patent Foramen Ovale: Systematic Review and Meta-Analysis
title_fullStr Presence of Atrial Fibrillation in Stroke Patients With Patent Foramen Ovale: Systematic Review and Meta-Analysis
title_full_unstemmed Presence of Atrial Fibrillation in Stroke Patients With Patent Foramen Ovale: Systematic Review and Meta-Analysis
title_short Presence of Atrial Fibrillation in Stroke Patients With Patent Foramen Ovale: Systematic Review and Meta-Analysis
title_sort presence of atrial fibrillation in stroke patients with patent foramen ovale: systematic review and meta-analysis
topic Neurology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8081982/
https://www.ncbi.nlm.nih.gov/pubmed/33935933
http://dx.doi.org/10.3389/fneur.2021.613758
work_keys_str_mv AT chenjessiezejun presenceofatrialfibrillationinstrokepatientswithpatentforamenovalesystematicreviewandmetaanalysis
AT thijsvincentn presenceofatrialfibrillationinstrokepatientswithpatentforamenovalesystematicreviewandmetaanalysis