Cargando…
Detection and monitoring of early dental caries and erosion using three-dimensional enhanced truncated-correlation photothermal coherence tomography imaging
Significance: Dental caries is the most common oral disease, with significant effects on healthcare systems and quality of life. Developing diagnostic methods for early caries detection is key to reducing this burden and enabling non-invasive treatment as opposed to the drill-and-fill approach. Aim:...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Society of Photo-Optical Instrumentation Engineers
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8084349/ https://www.ncbi.nlm.nih.gov/pubmed/33928770 http://dx.doi.org/10.1117/1.JBO.26.4.046004 |
_version_ | 1783686136710823936 |
---|---|
author | Roointan, Sohrab Tavakolian, Pantea Sivagurunathan, Koneswaran S. Mandelis, Andreas Abrams, Stephen H. |
author_facet | Roointan, Sohrab Tavakolian, Pantea Sivagurunathan, Koneswaran S. Mandelis, Andreas Abrams, Stephen H. |
author_sort | Roointan, Sohrab |
collection | PubMed |
description | Significance: Dental caries is the most common oral disease, with significant effects on healthcare systems and quality of life. Developing diagnostic methods for early caries detection is key to reducing this burden and enabling non-invasive treatment as opposed to the drill-and-fill approach. Aim: The application of a thermophotonic-based 3D imaging modality [enhanced truncated-correlation photothermal coherence tomography (eTC-PCT)] to early dental caries is investigated. To this end, the detection threshold, sensitivity, and 3D lesion reconstruction capability of eTC-PCT in imaging artificially generated caries and surface erosion are evaluated. Approach: eTC-PCT employs a diode laser with pulsed excitation, a mid-IR camera, and an in-house developed image reconstruction algorithm to produce depth-resolved 2D images and 3D reconstructions. Starting with healthy teeth, dental caries and surface erosion are simulated in vitro through application of specific demineralizing/eroding acidic solutions. Results: eTC-PCT can detect artificial caries as early as 2 days after onset of artificial demineralization and after 45 s of surface erosion, with a laser power equivalent to 64% of maximum permissible exposure. In both cases, the lesion is not visible to the eye and undetected by x-rays. eTC-PCT is capable of monitoring lesion progression in 2-day increments and generating 3D tomographic reconstructions of the advancing lesion. Conclusions: eTC-PCT shows great potential for further development as a dental imaging modality combining low detection threshold, high sensitivity to lesion progression, 3D reconstruction capability, and lack of ionizing radiation. These features enable early diagnosis and frequent monitoring, making eTC-PCT a promising technology for facilitating preventive dentistry. |
format | Online Article Text |
id | pubmed-8084349 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Society of Photo-Optical Instrumentation Engineers |
record_format | MEDLINE/PubMed |
spelling | pubmed-80843492021-04-30 Detection and monitoring of early dental caries and erosion using three-dimensional enhanced truncated-correlation photothermal coherence tomography imaging Roointan, Sohrab Tavakolian, Pantea Sivagurunathan, Koneswaran S. Mandelis, Andreas Abrams, Stephen H. J Biomed Opt Imaging Significance: Dental caries is the most common oral disease, with significant effects on healthcare systems and quality of life. Developing diagnostic methods for early caries detection is key to reducing this burden and enabling non-invasive treatment as opposed to the drill-and-fill approach. Aim: The application of a thermophotonic-based 3D imaging modality [enhanced truncated-correlation photothermal coherence tomography (eTC-PCT)] to early dental caries is investigated. To this end, the detection threshold, sensitivity, and 3D lesion reconstruction capability of eTC-PCT in imaging artificially generated caries and surface erosion are evaluated. Approach: eTC-PCT employs a diode laser with pulsed excitation, a mid-IR camera, and an in-house developed image reconstruction algorithm to produce depth-resolved 2D images and 3D reconstructions. Starting with healthy teeth, dental caries and surface erosion are simulated in vitro through application of specific demineralizing/eroding acidic solutions. Results: eTC-PCT can detect artificial caries as early as 2 days after onset of artificial demineralization and after 45 s of surface erosion, with a laser power equivalent to 64% of maximum permissible exposure. In both cases, the lesion is not visible to the eye and undetected by x-rays. eTC-PCT is capable of monitoring lesion progression in 2-day increments and generating 3D tomographic reconstructions of the advancing lesion. Conclusions: eTC-PCT shows great potential for further development as a dental imaging modality combining low detection threshold, high sensitivity to lesion progression, 3D reconstruction capability, and lack of ionizing radiation. These features enable early diagnosis and frequent monitoring, making eTC-PCT a promising technology for facilitating preventive dentistry. Society of Photo-Optical Instrumentation Engineers 2021-04-29 2021-04 /pmc/articles/PMC8084349/ /pubmed/33928770 http://dx.doi.org/10.1117/1.JBO.26.4.046004 Text en © 2021 The Authors https://creativecommons.org/licenses/by/4.0/Published by SPIE under a Creative Commons Attribution 4.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI. |
spellingShingle | Imaging Roointan, Sohrab Tavakolian, Pantea Sivagurunathan, Koneswaran S. Mandelis, Andreas Abrams, Stephen H. Detection and monitoring of early dental caries and erosion using three-dimensional enhanced truncated-correlation photothermal coherence tomography imaging |
title | Detection and monitoring of early dental caries and erosion using three-dimensional enhanced truncated-correlation photothermal coherence tomography imaging |
title_full | Detection and monitoring of early dental caries and erosion using three-dimensional enhanced truncated-correlation photothermal coherence tomography imaging |
title_fullStr | Detection and monitoring of early dental caries and erosion using three-dimensional enhanced truncated-correlation photothermal coherence tomography imaging |
title_full_unstemmed | Detection and monitoring of early dental caries and erosion using three-dimensional enhanced truncated-correlation photothermal coherence tomography imaging |
title_short | Detection and monitoring of early dental caries and erosion using three-dimensional enhanced truncated-correlation photothermal coherence tomography imaging |
title_sort | detection and monitoring of early dental caries and erosion using three-dimensional enhanced truncated-correlation photothermal coherence tomography imaging |
topic | Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8084349/ https://www.ncbi.nlm.nih.gov/pubmed/33928770 http://dx.doi.org/10.1117/1.JBO.26.4.046004 |
work_keys_str_mv | AT roointansohrab detectionandmonitoringofearlydentalcariesanderosionusingthreedimensionalenhancedtruncatedcorrelationphotothermalcoherencetomographyimaging AT tavakolianpantea detectionandmonitoringofearlydentalcariesanderosionusingthreedimensionalenhancedtruncatedcorrelationphotothermalcoherencetomographyimaging AT sivagurunathankoneswarans detectionandmonitoringofearlydentalcariesanderosionusingthreedimensionalenhancedtruncatedcorrelationphotothermalcoherencetomographyimaging AT mandelisandreas detectionandmonitoringofearlydentalcariesanderosionusingthreedimensionalenhancedtruncatedcorrelationphotothermalcoherencetomographyimaging AT abramsstephenh detectionandmonitoringofearlydentalcariesanderosionusingthreedimensionalenhancedtruncatedcorrelationphotothermalcoherencetomographyimaging |