Cargando…

A simplified formula to calculate fractional flow reserve in sequential lesions circumventing the measurement of coronary wedge pressure: The APIS-S pilot study

BACKGROUND: A simplified formula to calculate the predicted fractional flow reserve (FFR) in sequential coronary stenosis without balloon inflation is hereby proposed. METHODS: In patients with an indication for FFR and sequential coronary stenosis, FFR was recorded distally and between the lesions....

Descripción completa

Detalles Bibliográficos
Autores principales: Gutiérrez-Chico, Juan Luis, Cortés, Carlos, Jaguszewski, Miłosz, Schincariol, Michele, Amat-Santos, Ignacio J., Franco-Peláez, Juan A., Żuk, Grzegorz, Ciećwierz, Dariusz, Wojakowski, Wojciech, Navarro, Felipe, Tu, Shengxian, Ibáñez, Borja
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Via Medica 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8084377/
https://www.ncbi.nlm.nih.gov/pubmed/31257567
http://dx.doi.org/10.5603/CJ.a2019.0067
_version_ 1783686145447559168
author Gutiérrez-Chico, Juan Luis
Cortés, Carlos
Jaguszewski, Miłosz
Schincariol, Michele
Amat-Santos, Ignacio J.
Franco-Peláez, Juan A.
Żuk, Grzegorz
Ciećwierz, Dariusz
Wojakowski, Wojciech
Navarro, Felipe
Tu, Shengxian
Ibáñez, Borja
author_facet Gutiérrez-Chico, Juan Luis
Cortés, Carlos
Jaguszewski, Miłosz
Schincariol, Michele
Amat-Santos, Ignacio J.
Franco-Peláez, Juan A.
Żuk, Grzegorz
Ciećwierz, Dariusz
Wojakowski, Wojciech
Navarro, Felipe
Tu, Shengxian
Ibáñez, Borja
author_sort Gutiérrez-Chico, Juan Luis
collection PubMed
description BACKGROUND: A simplified formula to calculate the predicted fractional flow reserve (FFR) in sequential coronary stenosis without balloon inflation is hereby proposed. METHODS: In patients with an indication for FFR and sequential coronary stenosis, FFR was recorded distally and between the lesions. The predicted FFR for each stenosis was calculated with a novel formula. While treating one of the lesions, wedge pressure was measured during balloon inflation to calculate Pijls’ formula. FFR of the remaining lesion was finally recorded (measured FFR). RESULTS: Forty patients were enrolled in the study, 4 (10.0%) had a distal FFR > 0.80 and were excluded from the main analysis. In the remaining 36 patients, the novel formula and Pijls’ formula showed virtually absolute agreement (ICCa 0.999, R(2) = 0.997 for the proximal lesion, R(2) = 0.999 for the distal lesion, kappa 1.000, Se 100%, Sp 100%). The agreement between predicted and measured FFR was good (ICCa 0.820; 0.640–0.909, R(2) = 0.717, intercept = 0.05, slope = 0.92, kappa 0.748, Se 75%, Sp 96%). In 19 (47.5%) cases the use of the formula enabled the operator to freely decide which lesion should be treated first, an option not available if the percutaneous coronary intervention (PCI) were guided by the largest pressure drop across each lesion. CONCLUSIONS: The predicted FFR for each lesion in sequential coronary stenosis can be accurately calculated by a simplified formula circumventing the need for balloon inflation. This approach provides the operator upfront, with detailed information on physiology, thus having a potentially high impact on the corresponding PCI strategy.
format Online
Article
Text
id pubmed-8084377
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Via Medica
record_format MEDLINE/PubMed
spelling pubmed-80843772021-05-10 A simplified formula to calculate fractional flow reserve in sequential lesions circumventing the measurement of coronary wedge pressure: The APIS-S pilot study Gutiérrez-Chico, Juan Luis Cortés, Carlos Jaguszewski, Miłosz Schincariol, Michele Amat-Santos, Ignacio J. Franco-Peláez, Juan A. Żuk, Grzegorz Ciećwierz, Dariusz Wojakowski, Wojciech Navarro, Felipe Tu, Shengxian Ibáñez, Borja Cardiol J Interventional Cardiology BACKGROUND: A simplified formula to calculate the predicted fractional flow reserve (FFR) in sequential coronary stenosis without balloon inflation is hereby proposed. METHODS: In patients with an indication for FFR and sequential coronary stenosis, FFR was recorded distally and between the lesions. The predicted FFR for each stenosis was calculated with a novel formula. While treating one of the lesions, wedge pressure was measured during balloon inflation to calculate Pijls’ formula. FFR of the remaining lesion was finally recorded (measured FFR). RESULTS: Forty patients were enrolled in the study, 4 (10.0%) had a distal FFR > 0.80 and were excluded from the main analysis. In the remaining 36 patients, the novel formula and Pijls’ formula showed virtually absolute agreement (ICCa 0.999, R(2) = 0.997 for the proximal lesion, R(2) = 0.999 for the distal lesion, kappa 1.000, Se 100%, Sp 100%). The agreement between predicted and measured FFR was good (ICCa 0.820; 0.640–0.909, R(2) = 0.717, intercept = 0.05, slope = 0.92, kappa 0.748, Se 75%, Sp 96%). In 19 (47.5%) cases the use of the formula enabled the operator to freely decide which lesion should be treated first, an option not available if the percutaneous coronary intervention (PCI) were guided by the largest pressure drop across each lesion. CONCLUSIONS: The predicted FFR for each lesion in sequential coronary stenosis can be accurately calculated by a simplified formula circumventing the need for balloon inflation. This approach provides the operator upfront, with detailed information on physiology, thus having a potentially high impact on the corresponding PCI strategy. Via Medica 2019-08-22 /pmc/articles/PMC8084377/ /pubmed/31257567 http://dx.doi.org/10.5603/CJ.a2019.0067 Text en Copyright © 2019 Via Medica https://creativecommons.org/licenses/by-nc-nd/4.0/This article is available in open access under Creative Common Attribution-Non-Commercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0) license, allowing to download articles and share them with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially.
spellingShingle Interventional Cardiology
Gutiérrez-Chico, Juan Luis
Cortés, Carlos
Jaguszewski, Miłosz
Schincariol, Michele
Amat-Santos, Ignacio J.
Franco-Peláez, Juan A.
Żuk, Grzegorz
Ciećwierz, Dariusz
Wojakowski, Wojciech
Navarro, Felipe
Tu, Shengxian
Ibáñez, Borja
A simplified formula to calculate fractional flow reserve in sequential lesions circumventing the measurement of coronary wedge pressure: The APIS-S pilot study
title A simplified formula to calculate fractional flow reserve in sequential lesions circumventing the measurement of coronary wedge pressure: The APIS-S pilot study
title_full A simplified formula to calculate fractional flow reserve in sequential lesions circumventing the measurement of coronary wedge pressure: The APIS-S pilot study
title_fullStr A simplified formula to calculate fractional flow reserve in sequential lesions circumventing the measurement of coronary wedge pressure: The APIS-S pilot study
title_full_unstemmed A simplified formula to calculate fractional flow reserve in sequential lesions circumventing the measurement of coronary wedge pressure: The APIS-S pilot study
title_short A simplified formula to calculate fractional flow reserve in sequential lesions circumventing the measurement of coronary wedge pressure: The APIS-S pilot study
title_sort simplified formula to calculate fractional flow reserve in sequential lesions circumventing the measurement of coronary wedge pressure: the apis-s pilot study
topic Interventional Cardiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8084377/
https://www.ncbi.nlm.nih.gov/pubmed/31257567
http://dx.doi.org/10.5603/CJ.a2019.0067
work_keys_str_mv AT gutierrezchicojuanluis asimplifiedformulatocalculatefractionalflowreserveinsequentiallesionscircumventingthemeasurementofcoronarywedgepressuretheapisspilotstudy
AT cortescarlos asimplifiedformulatocalculatefractionalflowreserveinsequentiallesionscircumventingthemeasurementofcoronarywedgepressuretheapisspilotstudy
AT jaguszewskimiłosz asimplifiedformulatocalculatefractionalflowreserveinsequentiallesionscircumventingthemeasurementofcoronarywedgepressuretheapisspilotstudy
AT schincariolmichele asimplifiedformulatocalculatefractionalflowreserveinsequentiallesionscircumventingthemeasurementofcoronarywedgepressuretheapisspilotstudy
AT amatsantosignacioj asimplifiedformulatocalculatefractionalflowreserveinsequentiallesionscircumventingthemeasurementofcoronarywedgepressuretheapisspilotstudy
AT francopelaezjuana asimplifiedformulatocalculatefractionalflowreserveinsequentiallesionscircumventingthemeasurementofcoronarywedgepressuretheapisspilotstudy
AT zukgrzegorz asimplifiedformulatocalculatefractionalflowreserveinsequentiallesionscircumventingthemeasurementofcoronarywedgepressuretheapisspilotstudy
AT ciecwierzdariusz asimplifiedformulatocalculatefractionalflowreserveinsequentiallesionscircumventingthemeasurementofcoronarywedgepressuretheapisspilotstudy
AT wojakowskiwojciech asimplifiedformulatocalculatefractionalflowreserveinsequentiallesionscircumventingthemeasurementofcoronarywedgepressuretheapisspilotstudy
AT navarrofelipe asimplifiedformulatocalculatefractionalflowreserveinsequentiallesionscircumventingthemeasurementofcoronarywedgepressuretheapisspilotstudy
AT tushengxian asimplifiedformulatocalculatefractionalflowreserveinsequentiallesionscircumventingthemeasurementofcoronarywedgepressuretheapisspilotstudy
AT ibanezborja asimplifiedformulatocalculatefractionalflowreserveinsequentiallesionscircumventingthemeasurementofcoronarywedgepressuretheapisspilotstudy
AT gutierrezchicojuanluis simplifiedformulatocalculatefractionalflowreserveinsequentiallesionscircumventingthemeasurementofcoronarywedgepressuretheapisspilotstudy
AT cortescarlos simplifiedformulatocalculatefractionalflowreserveinsequentiallesionscircumventingthemeasurementofcoronarywedgepressuretheapisspilotstudy
AT jaguszewskimiłosz simplifiedformulatocalculatefractionalflowreserveinsequentiallesionscircumventingthemeasurementofcoronarywedgepressuretheapisspilotstudy
AT schincariolmichele simplifiedformulatocalculatefractionalflowreserveinsequentiallesionscircumventingthemeasurementofcoronarywedgepressuretheapisspilotstudy
AT amatsantosignacioj simplifiedformulatocalculatefractionalflowreserveinsequentiallesionscircumventingthemeasurementofcoronarywedgepressuretheapisspilotstudy
AT francopelaezjuana simplifiedformulatocalculatefractionalflowreserveinsequentiallesionscircumventingthemeasurementofcoronarywedgepressuretheapisspilotstudy
AT zukgrzegorz simplifiedformulatocalculatefractionalflowreserveinsequentiallesionscircumventingthemeasurementofcoronarywedgepressuretheapisspilotstudy
AT ciecwierzdariusz simplifiedformulatocalculatefractionalflowreserveinsequentiallesionscircumventingthemeasurementofcoronarywedgepressuretheapisspilotstudy
AT wojakowskiwojciech simplifiedformulatocalculatefractionalflowreserveinsequentiallesionscircumventingthemeasurementofcoronarywedgepressuretheapisspilotstudy
AT navarrofelipe simplifiedformulatocalculatefractionalflowreserveinsequentiallesionscircumventingthemeasurementofcoronarywedgepressuretheapisspilotstudy
AT tushengxian simplifiedformulatocalculatefractionalflowreserveinsequentiallesionscircumventingthemeasurementofcoronarywedgepressuretheapisspilotstudy
AT ibanezborja simplifiedformulatocalculatefractionalflowreserveinsequentiallesionscircumventingthemeasurementofcoronarywedgepressuretheapisspilotstudy