Cargando…
Five-millimeter Trocar Site Hernia with a Parastomal Hernia Sac: A Case Report
Here, we report our experience with a 5-mm trocar site hernia (TSH) near a stoma. This is the first report describing the relationship between TSH and extraperitoneal colostomy. A 72-year-old man underwent laparoscopic abdominoperineal resection with extraperitoneal sigmoid colostomy and partial hep...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Japan Society of Coloproctology
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8084539/ https://www.ncbi.nlm.nih.gov/pubmed/33937562 http://dx.doi.org/10.23922/jarc.2020-078 |
_version_ | 1783686174096752640 |
---|---|
author | Fuse, Masahiro Ozawa, Mayumi Sato, Seiya Goto, Koki Suwa, Yusuke Nakagawa, Kazuya Ishibe, Atsushi Watanabe, Jun Endo, Itaru |
author_facet | Fuse, Masahiro Ozawa, Mayumi Sato, Seiya Goto, Koki Suwa, Yusuke Nakagawa, Kazuya Ishibe, Atsushi Watanabe, Jun Endo, Itaru |
author_sort | Fuse, Masahiro |
collection | PubMed |
description | Here, we report our experience with a 5-mm trocar site hernia (TSH) near a stoma. This is the first report describing the relationship between TSH and extraperitoneal colostomy. A 72-year-old man underwent laparoscopic abdominoperineal resection with extraperitoneal sigmoid colostomy and partial hepatectomy for rectal cancer accompanied by synchronous liver metastasis (pT3N1aM1a Stage IVA Union for International Cancer Control [UICC] 8th edition). The surgical procedures were completely performed without morbidity. After 1 year, he presented to our hospital with sudden nausea. Computed tomography (CT) revealed small bowel obstruction due to a 5-mm TSH, 1 cm from the stoma. The patient underwent laparoscopic hernia repair. The incidence of a 5-mm TSH is low. However, an abdominal wall vulnerability caused by the extensive exfoliation of the retroperitoneum due to the construction of the colostomy was observed, and the extraperitoneal colostomy influenced the onset of the 5-mm TSH. When the port and hernia sites are located in close proximity to each other, even a 5-mm trocar site may increase the incidence of TSH. |
format | Online Article Text |
id | pubmed-8084539 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | The Japan Society of Coloproctology |
record_format | MEDLINE/PubMed |
spelling | pubmed-80845392021-04-30 Five-millimeter Trocar Site Hernia with a Parastomal Hernia Sac: A Case Report Fuse, Masahiro Ozawa, Mayumi Sato, Seiya Goto, Koki Suwa, Yusuke Nakagawa, Kazuya Ishibe, Atsushi Watanabe, Jun Endo, Itaru J Anus Rectum Colon Case Report Here, we report our experience with a 5-mm trocar site hernia (TSH) near a stoma. This is the first report describing the relationship between TSH and extraperitoneal colostomy. A 72-year-old man underwent laparoscopic abdominoperineal resection with extraperitoneal sigmoid colostomy and partial hepatectomy for rectal cancer accompanied by synchronous liver metastasis (pT3N1aM1a Stage IVA Union for International Cancer Control [UICC] 8th edition). The surgical procedures were completely performed without morbidity. After 1 year, he presented to our hospital with sudden nausea. Computed tomography (CT) revealed small bowel obstruction due to a 5-mm TSH, 1 cm from the stoma. The patient underwent laparoscopic hernia repair. The incidence of a 5-mm TSH is low. However, an abdominal wall vulnerability caused by the extensive exfoliation of the retroperitoneum due to the construction of the colostomy was observed, and the extraperitoneal colostomy influenced the onset of the 5-mm TSH. When the port and hernia sites are located in close proximity to each other, even a 5-mm trocar site may increase the incidence of TSH. The Japan Society of Coloproctology 2021-04-28 /pmc/articles/PMC8084539/ /pubmed/33937562 http://dx.doi.org/10.23922/jarc.2020-078 Text en Copyright © 2021 by The Japan Society of Coloproctology https://creativecommons.org/licenses/by-nc-nd/4.0/Journal of the Anus, Rectum and Colon is an Open Access journal distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view the details of this license, please visit (https://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case Report Fuse, Masahiro Ozawa, Mayumi Sato, Seiya Goto, Koki Suwa, Yusuke Nakagawa, Kazuya Ishibe, Atsushi Watanabe, Jun Endo, Itaru Five-millimeter Trocar Site Hernia with a Parastomal Hernia Sac: A Case Report |
title | Five-millimeter Trocar Site Hernia with a Parastomal Hernia Sac: A Case Report |
title_full | Five-millimeter Trocar Site Hernia with a Parastomal Hernia Sac: A Case Report |
title_fullStr | Five-millimeter Trocar Site Hernia with a Parastomal Hernia Sac: A Case Report |
title_full_unstemmed | Five-millimeter Trocar Site Hernia with a Parastomal Hernia Sac: A Case Report |
title_short | Five-millimeter Trocar Site Hernia with a Parastomal Hernia Sac: A Case Report |
title_sort | five-millimeter trocar site hernia with a parastomal hernia sac: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8084539/ https://www.ncbi.nlm.nih.gov/pubmed/33937562 http://dx.doi.org/10.23922/jarc.2020-078 |
work_keys_str_mv | AT fusemasahiro fivemillimetertrocarsiteherniawithaparastomalherniasacacasereport AT ozawamayumi fivemillimetertrocarsiteherniawithaparastomalherniasacacasereport AT satoseiya fivemillimetertrocarsiteherniawithaparastomalherniasacacasereport AT gotokoki fivemillimetertrocarsiteherniawithaparastomalherniasacacasereport AT suwayusuke fivemillimetertrocarsiteherniawithaparastomalherniasacacasereport AT nakagawakazuya fivemillimetertrocarsiteherniawithaparastomalherniasacacasereport AT ishibeatsushi fivemillimetertrocarsiteherniawithaparastomalherniasacacasereport AT watanabejun fivemillimetertrocarsiteherniawithaparastomalherniasacacasereport AT endoitaru fivemillimetertrocarsiteherniawithaparastomalherniasacacasereport |