Cargando…
Visualization Ability of Phase-Contrast Synchrotron-Based X-Ray Imaging Using an X-Ray Interferometer in Soft Tissue Tumors
Phase-contrast synchrotron-based X-ray imaging using an X-ray interferometer provides high sensitivity and high spatial resolution, and it has the ability to depict the fine morphological structures of biological soft tissues, including tumors. In this study, we quantitatively compared phase-contras...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8085371/ https://www.ncbi.nlm.nih.gov/pubmed/33896273 http://dx.doi.org/10.1177/15330338211010121 |
_version_ | 1783686324676460544 |
---|---|
author | Lwin, Thet-Thet Yoneyama, Akio Maruyama, Hiroko Takeda, Tohoru |
author_facet | Lwin, Thet-Thet Yoneyama, Akio Maruyama, Hiroko Takeda, Tohoru |
author_sort | Lwin, Thet-Thet |
collection | PubMed |
description | Phase-contrast synchrotron-based X-ray imaging using an X-ray interferometer provides high sensitivity and high spatial resolution, and it has the ability to depict the fine morphological structures of biological soft tissues, including tumors. In this study, we quantitatively compared phase-contrast synchrotron-based X-ray computed tomography images and images of histopathological hematoxylin-eosin-stained sections of spontaneously occurring rat testicular tumors that contained different types of cells. The absolute densities measured on the phase-contrast synchrotron-based X-ray computed tomography images correlated well with the densities of the nuclear chromatin in the histological images, thereby demonstrating the ability of phase-contrast synchrotron-based X-ray imaging using an X-ray interferometer to reliably identify the characteristics of cancer cells within solid soft tissue tumors. In addition, 3-dimensional synchrotron-based phase-contrast X-ray computed tomography enables screening for different structures within tumors, such as solid, cystic, and fibrous tissues, and blood clots, from any direction and with a spatial resolution down to 26 μm. Thus, phase-contrast synchrotron-based X-ray imaging using an X-ray interferometer shows potential for being useful in preclinical cancer research by providing the ability to depict the characteristics of tumor cells and by offering 3-dimensional information capabilities. |
format | Online Article Text |
id | pubmed-8085371 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-80853712021-05-13 Visualization Ability of Phase-Contrast Synchrotron-Based X-Ray Imaging Using an X-Ray Interferometer in Soft Tissue Tumors Lwin, Thet-Thet Yoneyama, Akio Maruyama, Hiroko Takeda, Tohoru Technol Cancer Res Treat Original Article Phase-contrast synchrotron-based X-ray imaging using an X-ray interferometer provides high sensitivity and high spatial resolution, and it has the ability to depict the fine morphological structures of biological soft tissues, including tumors. In this study, we quantitatively compared phase-contrast synchrotron-based X-ray computed tomography images and images of histopathological hematoxylin-eosin-stained sections of spontaneously occurring rat testicular tumors that contained different types of cells. The absolute densities measured on the phase-contrast synchrotron-based X-ray computed tomography images correlated well with the densities of the nuclear chromatin in the histological images, thereby demonstrating the ability of phase-contrast synchrotron-based X-ray imaging using an X-ray interferometer to reliably identify the characteristics of cancer cells within solid soft tissue tumors. In addition, 3-dimensional synchrotron-based phase-contrast X-ray computed tomography enables screening for different structures within tumors, such as solid, cystic, and fibrous tissues, and blood clots, from any direction and with a spatial resolution down to 26 μm. Thus, phase-contrast synchrotron-based X-ray imaging using an X-ray interferometer shows potential for being useful in preclinical cancer research by providing the ability to depict the characteristics of tumor cells and by offering 3-dimensional information capabilities. SAGE Publications 2021-04-26 /pmc/articles/PMC8085371/ /pubmed/33896273 http://dx.doi.org/10.1177/15330338211010121 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Article Lwin, Thet-Thet Yoneyama, Akio Maruyama, Hiroko Takeda, Tohoru Visualization Ability of Phase-Contrast Synchrotron-Based X-Ray Imaging Using an X-Ray Interferometer in Soft Tissue Tumors |
title | Visualization Ability of Phase-Contrast Synchrotron-Based X-Ray Imaging Using an X-Ray Interferometer in Soft Tissue Tumors |
title_full | Visualization Ability of Phase-Contrast Synchrotron-Based X-Ray Imaging Using an X-Ray Interferometer in Soft Tissue Tumors |
title_fullStr | Visualization Ability of Phase-Contrast Synchrotron-Based X-Ray Imaging Using an X-Ray Interferometer in Soft Tissue Tumors |
title_full_unstemmed | Visualization Ability of Phase-Contrast Synchrotron-Based X-Ray Imaging Using an X-Ray Interferometer in Soft Tissue Tumors |
title_short | Visualization Ability of Phase-Contrast Synchrotron-Based X-Ray Imaging Using an X-Ray Interferometer in Soft Tissue Tumors |
title_sort | visualization ability of phase-contrast synchrotron-based x-ray imaging using an x-ray interferometer in soft tissue tumors |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8085371/ https://www.ncbi.nlm.nih.gov/pubmed/33896273 http://dx.doi.org/10.1177/15330338211010121 |
work_keys_str_mv | AT lwinthetthet visualizationabilityofphasecontrastsynchrotronbasedxrayimagingusinganxrayinterferometerinsofttissuetumors AT yoneyamaakio visualizationabilityofphasecontrastsynchrotronbasedxrayimagingusinganxrayinterferometerinsofttissuetumors AT maruyamahiroko visualizationabilityofphasecontrastsynchrotronbasedxrayimagingusinganxrayinterferometerinsofttissuetumors AT takedatohoru visualizationabilityofphasecontrastsynchrotronbasedxrayimagingusinganxrayinterferometerinsofttissuetumors |