Evaluation of Thyroid Fine-Needle Aspiration Biopsies according to Cytological Methods and Comparison with Histopathological Diagnosis

OBJECTIVES: In this study, we aim to compare the results of aspiration of thyroid nodules evaluated according to the Bethesda category (BC) with tissue diagnoses in the operation materials and to compare the sensitivity, specificity and accuracy rates according to cytology methods. METHODS: The prev...

Descripción completa

Detalles Bibliográficos
Autores principales: Ucak, Ramazan, Eryilmaz, Ozlem Ton, Ozguven, Banu Yılmaz, Uludag, Mehmet, Kabukcuoğlu, Fevziye
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Kare Publishing 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8085446/
https://www.ncbi.nlm.nih.gov/pubmed/33935542
http://dx.doi.org/10.14744/SEMB.2020.94752
_version_ 1783686342418366464
author Ucak, Ramazan
Eryilmaz, Ozlem Ton
Ozguven, Banu Yılmaz
Uludag, Mehmet
Kabukcuoğlu, Fevziye
author_facet Ucak, Ramazan
Eryilmaz, Ozlem Ton
Ozguven, Banu Yılmaz
Uludag, Mehmet
Kabukcuoğlu, Fevziye
author_sort Ucak, Ramazan
collection PubMed
description OBJECTIVES: In this study, we aim to compare the results of aspiration of thyroid nodules evaluated according to the Bethesda category (BC) with tissue diagnoses in the operation materials and to compare the sensitivity, specificity and accuracy rates according to cytology methods. METHODS: The previous fine-needle aspiration biopsy (FNAB) of thyroid nodules of 879 cases diagnosed histopathologically between 2010 and 2017 was examined. The FNAB results determined according to the Bethesda system were matched with tissue diagnoses, sensitivity, specificity, and accuracy rates were investigated according to cytology methods. RESULTS: Sensitivity, specificity, Positive predictive value (PPV), Negative predictive value (NPV) and accuracy rates were found in all FNAB results (in units of %; Sensitivity; 84.7, Specificity; 81.1, PPV; 74.1, NPV; 89.2, Accuracy; 82.5). All of the cytological evaluation methods of thyroid FNABs were found to be reliable and effective (Generally, the results are 80% and above). Specificity and accuracy rates were close to the general average (82.5%) in all methods. However, in cases evaluated with liquid base cytology (LBC) method and in addition to LBC or conventional smear (CS), the sensitivity rates in cases where cell block (CB) were evaluated together were higher than cases in which LBC and CS were used alone (92.6% and 91.0%). When examined statistically, there was no significant difference concerning sensitivity, specificity and accuracy rates of cytological methods (p>0.05, respectively, p=0.576, 0.065, 0.643). CONCLUSION: In cytopathology, when evaluating thyroid aspirations, it is seen that the LBC method is used instead of CS. In our study, we recommend the use of the LBC method, which seems to have the highest sensitivity (taking into account its technical advantages), instead of CS. However, we think that both CS and LBC methods should be evaluated by supporting them with cell block sections.
format Online
Article
Text
id pubmed-8085446
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Kare Publishing
record_format MEDLINE/PubMed
spelling pubmed-80854462021-04-30 Evaluation of Thyroid Fine-Needle Aspiration Biopsies according to Cytological Methods and Comparison with Histopathological Diagnosis Ucak, Ramazan Eryilmaz, Ozlem Ton Ozguven, Banu Yılmaz Uludag, Mehmet Kabukcuoğlu, Fevziye Sisli Etfal Hastan Tip Bul Original Research OBJECTIVES: In this study, we aim to compare the results of aspiration of thyroid nodules evaluated according to the Bethesda category (BC) with tissue diagnoses in the operation materials and to compare the sensitivity, specificity and accuracy rates according to cytology methods. METHODS: The previous fine-needle aspiration biopsy (FNAB) of thyroid nodules of 879 cases diagnosed histopathologically between 2010 and 2017 was examined. The FNAB results determined according to the Bethesda system were matched with tissue diagnoses, sensitivity, specificity, and accuracy rates were investigated according to cytology methods. RESULTS: Sensitivity, specificity, Positive predictive value (PPV), Negative predictive value (NPV) and accuracy rates were found in all FNAB results (in units of %; Sensitivity; 84.7, Specificity; 81.1, PPV; 74.1, NPV; 89.2, Accuracy; 82.5). All of the cytological evaluation methods of thyroid FNABs were found to be reliable and effective (Generally, the results are 80% and above). Specificity and accuracy rates were close to the general average (82.5%) in all methods. However, in cases evaluated with liquid base cytology (LBC) method and in addition to LBC or conventional smear (CS), the sensitivity rates in cases where cell block (CB) were evaluated together were higher than cases in which LBC and CS were used alone (92.6% and 91.0%). When examined statistically, there was no significant difference concerning sensitivity, specificity and accuracy rates of cytological methods (p>0.05, respectively, p=0.576, 0.065, 0.643). CONCLUSION: In cytopathology, when evaluating thyroid aspirations, it is seen that the LBC method is used instead of CS. In our study, we recommend the use of the LBC method, which seems to have the highest sensitivity (taking into account its technical advantages), instead of CS. However, we think that both CS and LBC methods should be evaluated by supporting them with cell block sections. Kare Publishing 2021-03-17 /pmc/articles/PMC8085446/ /pubmed/33935542 http://dx.doi.org/10.14744/SEMB.2020.94752 Text en Copyright: © 2021 by The Medical Bulletin of Sisli Etfal Hospital https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ).
spellingShingle Original Research
Ucak, Ramazan
Eryilmaz, Ozlem Ton
Ozguven, Banu Yılmaz
Uludag, Mehmet
Kabukcuoğlu, Fevziye
Evaluation of Thyroid Fine-Needle Aspiration Biopsies according to Cytological Methods and Comparison with Histopathological Diagnosis
title Evaluation of Thyroid Fine-Needle Aspiration Biopsies according to Cytological Methods and Comparison with Histopathological Diagnosis
title_full Evaluation of Thyroid Fine-Needle Aspiration Biopsies according to Cytological Methods and Comparison with Histopathological Diagnosis
title_fullStr Evaluation of Thyroid Fine-Needle Aspiration Biopsies according to Cytological Methods and Comparison with Histopathological Diagnosis
title_full_unstemmed Evaluation of Thyroid Fine-Needle Aspiration Biopsies according to Cytological Methods and Comparison with Histopathological Diagnosis
title_short Evaluation of Thyroid Fine-Needle Aspiration Biopsies according to Cytological Methods and Comparison with Histopathological Diagnosis
title_sort evaluation of thyroid fine-needle aspiration biopsies according to cytological methods and comparison with histopathological diagnosis
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8085446/
https://www.ncbi.nlm.nih.gov/pubmed/33935542
http://dx.doi.org/10.14744/SEMB.2020.94752
work_keys_str_mv AT ucakramazan evaluationofthyroidfineneedleaspirationbiopsiesaccordingtocytologicalmethodsandcomparisonwithhistopathologicaldiagnosis
AT eryilmazozlemton evaluationofthyroidfineneedleaspirationbiopsiesaccordingtocytologicalmethodsandcomparisonwithhistopathologicaldiagnosis
AT ozguvenbanuyılmaz evaluationofthyroidfineneedleaspirationbiopsiesaccordingtocytologicalmethodsandcomparisonwithhistopathologicaldiagnosis
AT uludagmehmet evaluationofthyroidfineneedleaspirationbiopsiesaccordingtocytologicalmethodsandcomparisonwithhistopathologicaldiagnosis
AT kabukcuoglufevziye evaluationofthyroidfineneedleaspirationbiopsiesaccordingtocytologicalmethodsandcomparisonwithhistopathologicaldiagnosis