Safety Evaluation of the Omnipod® 5 Automated Insulin Delivery System Over Three Months of Use in Children With Type 1 Diabetes (T1D)

Advances in diabetes technology have transformed the treatment paradigm for T1D, yet the burden of the disease remains significant. The pediatric population poses unique challenges to glucose management with unpredictable exercise and food consumption. The Omnipod 5 System is a novel hybrid closed-l...

Descripción completa

Detalles Bibliográficos
Autores principales: Buckingham, Bruce A, Forlenza, Gregory P, Criego, Amy B, Hansen, David W, Bode, Bruce W, Brown, Sue A, MacLeish, Sarah A, Pinsker, Jordan E, DeSalvo, Daniel J, Sherr, Jennifer L, Mehta, Sanjeev N, Laffel, Lori M, Bhargava, Anuj, Ly, Trang T
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8090047/
http://dx.doi.org/10.1210/jendso/bvab048.927
_version_ 1783687187428016128
author Buckingham, Bruce A
Forlenza, Gregory P
Criego, Amy B
Hansen, David W
Bode, Bruce W
Brown, Sue A
MacLeish, Sarah A
Pinsker, Jordan E
DeSalvo, Daniel J
Sherr, Jennifer L
Mehta, Sanjeev N
Laffel, Lori M
Bhargava, Anuj
Ly, Trang T
author_facet Buckingham, Bruce A
Forlenza, Gregory P
Criego, Amy B
Hansen, David W
Bode, Bruce W
Brown, Sue A
MacLeish, Sarah A
Pinsker, Jordan E
DeSalvo, Daniel J
Sherr, Jennifer L
Mehta, Sanjeev N
Laffel, Lori M
Bhargava, Anuj
Ly, Trang T
author_sort Buckingham, Bruce A
collection PubMed
description Advances in diabetes technology have transformed the treatment paradigm for T1D, yet the burden of the disease remains significant. The pediatric population poses unique challenges to glucose management with unpredictable exercise and food consumption. The Omnipod 5 System is a novel hybrid closed-loop (HCL) system with fully on-body operation. A tubeless insulin pump (pod) containing a personalized Model Predictive Control algorithm communicates directly with a Dexcom G6 continuous glucose monitor (CGM, or sensor) to automate insulin delivery. Therapy customization is enabled through glucose targets from 110–150 mg/dL, adjustable by time of day, which is a critical component to individualize glucose management in children. We report on the first, pivotal outpatient safety evaluation of the Omnipod 5 System in a large cohort of children with T1D. Participants aged 6–13.9y with T1D≥6 months and A1C<10% used the HCL system for 3 months at home after a 14-day run-in phase of their standard therapy (ST, included both pump therapy and multiple daily injections). The primary safety and effectiveness endpoints, respectively, were occurrence of severe hypoglycemia (SH) and diabetic ketoacidosis (DKA), and change in A1C and sensor glucose percent time in target range (TIR) (70–180 mg/dL) during HCL compared with ST. Participants (N=112) were aged (mean±SD) 10.3±2.2y with T1D duration 4.7±2.6y and baseline A1C 7.7±0.9% (range 5.8–10.3%). TIR increased significantly from ST to HCL, from 52.5±15.6% to 68.0±8.1% (p<0.0001), corresponding to an additional 3.7 hours/day in target range. A1C at end of study was reduced by 0.7% to 7.0±0.6% (p<0.0001). Percentages of time in hyperglycemia were reduced: >180 mg/dL from 45.3±16.7% to 30.2±8.7% and ≥250 mg/dL from 19.1±13.1% to 9.6±5.4% (both p<0.0001). Percentages of time in hypoglycemia remained low from ST to HCL: <54 mg/dL from 0.4±0.8% to 0.3±0.3% and <70 mg/dL from 2.2±2.7% to 1.8±1.4% (both p>0.05). Mean glucose decreased from 183±32 to 160±15 mg/dL (p<0.0001). During the HCL phase there was 1 episode of SH (delayed eating after pre-meal bolus) and 1 episode of DKA (suspected infusion site failure) reported. Virtually all participants completing the pivotal study (99%) continued system use during an extension phase. In this multi-center pivotal study in a large cohort of children with T1D, the Omnipod 5 System was safe and effective when used for 3 months at home. There were significant improvements in both TIR and A1C, while time below range (<70 mg/dL) remained low. The beneficial glycemic outcomes are critical for children, given that neurologic outcomes can be negatively impacted by hyperglycemia. The current results and commitment to the extension phase emphasize the safe and effective use of the HCL system, as well as the preference for the Omnipod 5 System over participants’ previous therapy.
format Online
Article
Text
id pubmed-8090047
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-80900472021-05-06 Safety Evaluation of the Omnipod® 5 Automated Insulin Delivery System Over Three Months of Use in Children With Type 1 Diabetes (T1D) Buckingham, Bruce A Forlenza, Gregory P Criego, Amy B Hansen, David W Bode, Bruce W Brown, Sue A MacLeish, Sarah A Pinsker, Jordan E DeSalvo, Daniel J Sherr, Jennifer L Mehta, Sanjeev N Laffel, Lori M Bhargava, Anuj Ly, Trang T J Endocr Soc Diabetes Mellitus and Glucose Metabolism Advances in diabetes technology have transformed the treatment paradigm for T1D, yet the burden of the disease remains significant. The pediatric population poses unique challenges to glucose management with unpredictable exercise and food consumption. The Omnipod 5 System is a novel hybrid closed-loop (HCL) system with fully on-body operation. A tubeless insulin pump (pod) containing a personalized Model Predictive Control algorithm communicates directly with a Dexcom G6 continuous glucose monitor (CGM, or sensor) to automate insulin delivery. Therapy customization is enabled through glucose targets from 110–150 mg/dL, adjustable by time of day, which is a critical component to individualize glucose management in children. We report on the first, pivotal outpatient safety evaluation of the Omnipod 5 System in a large cohort of children with T1D. Participants aged 6–13.9y with T1D≥6 months and A1C<10% used the HCL system for 3 months at home after a 14-day run-in phase of their standard therapy (ST, included both pump therapy and multiple daily injections). The primary safety and effectiveness endpoints, respectively, were occurrence of severe hypoglycemia (SH) and diabetic ketoacidosis (DKA), and change in A1C and sensor glucose percent time in target range (TIR) (70–180 mg/dL) during HCL compared with ST. Participants (N=112) were aged (mean±SD) 10.3±2.2y with T1D duration 4.7±2.6y and baseline A1C 7.7±0.9% (range 5.8–10.3%). TIR increased significantly from ST to HCL, from 52.5±15.6% to 68.0±8.1% (p<0.0001), corresponding to an additional 3.7 hours/day in target range. A1C at end of study was reduced by 0.7% to 7.0±0.6% (p<0.0001). Percentages of time in hyperglycemia were reduced: >180 mg/dL from 45.3±16.7% to 30.2±8.7% and ≥250 mg/dL from 19.1±13.1% to 9.6±5.4% (both p<0.0001). Percentages of time in hypoglycemia remained low from ST to HCL: <54 mg/dL from 0.4±0.8% to 0.3±0.3% and <70 mg/dL from 2.2±2.7% to 1.8±1.4% (both p>0.05). Mean glucose decreased from 183±32 to 160±15 mg/dL (p<0.0001). During the HCL phase there was 1 episode of SH (delayed eating after pre-meal bolus) and 1 episode of DKA (suspected infusion site failure) reported. Virtually all participants completing the pivotal study (99%) continued system use during an extension phase. In this multi-center pivotal study in a large cohort of children with T1D, the Omnipod 5 System was safe and effective when used for 3 months at home. There were significant improvements in both TIR and A1C, while time below range (<70 mg/dL) remained low. The beneficial glycemic outcomes are critical for children, given that neurologic outcomes can be negatively impacted by hyperglycemia. The current results and commitment to the extension phase emphasize the safe and effective use of the HCL system, as well as the preference for the Omnipod 5 System over participants’ previous therapy. Oxford University Press 2021-05-03 /pmc/articles/PMC8090047/ http://dx.doi.org/10.1210/jendso/bvab048.927 Text en © The Author(s) 2021. Published by Oxford University Press on behalf of the Endocrine Society. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) ), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Diabetes Mellitus and Glucose Metabolism
Buckingham, Bruce A
Forlenza, Gregory P
Criego, Amy B
Hansen, David W
Bode, Bruce W
Brown, Sue A
MacLeish, Sarah A
Pinsker, Jordan E
DeSalvo, Daniel J
Sherr, Jennifer L
Mehta, Sanjeev N
Laffel, Lori M
Bhargava, Anuj
Ly, Trang T
Safety Evaluation of the Omnipod® 5 Automated Insulin Delivery System Over Three Months of Use in Children With Type 1 Diabetes (T1D)
title Safety Evaluation of the Omnipod® 5 Automated Insulin Delivery System Over Three Months of Use in Children With Type 1 Diabetes (T1D)
title_full Safety Evaluation of the Omnipod® 5 Automated Insulin Delivery System Over Three Months of Use in Children With Type 1 Diabetes (T1D)
title_fullStr Safety Evaluation of the Omnipod® 5 Automated Insulin Delivery System Over Three Months of Use in Children With Type 1 Diabetes (T1D)
title_full_unstemmed Safety Evaluation of the Omnipod® 5 Automated Insulin Delivery System Over Three Months of Use in Children With Type 1 Diabetes (T1D)
title_short Safety Evaluation of the Omnipod® 5 Automated Insulin Delivery System Over Three Months of Use in Children With Type 1 Diabetes (T1D)
title_sort safety evaluation of the omnipod® 5 automated insulin delivery system over three months of use in children with type 1 diabetes (t1d)
topic Diabetes Mellitus and Glucose Metabolism
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8090047/
http://dx.doi.org/10.1210/jendso/bvab048.927
work_keys_str_mv AT buckinghambrucea safetyevaluationoftheomnipod5automatedinsulindeliverysystemoverthreemonthsofuseinchildrenwithtype1diabetest1d
AT forlenzagregoryp safetyevaluationoftheomnipod5automatedinsulindeliverysystemoverthreemonthsofuseinchildrenwithtype1diabetest1d
AT criegoamyb safetyevaluationoftheomnipod5automatedinsulindeliverysystemoverthreemonthsofuseinchildrenwithtype1diabetest1d
AT hansendavidw safetyevaluationoftheomnipod5automatedinsulindeliverysystemoverthreemonthsofuseinchildrenwithtype1diabetest1d
AT bodebrucew safetyevaluationoftheomnipod5automatedinsulindeliverysystemoverthreemonthsofuseinchildrenwithtype1diabetest1d
AT brownsuea safetyevaluationoftheomnipod5automatedinsulindeliverysystemoverthreemonthsofuseinchildrenwithtype1diabetest1d
AT macleishsaraha safetyevaluationoftheomnipod5automatedinsulindeliverysystemoverthreemonthsofuseinchildrenwithtype1diabetest1d
AT pinskerjordane safetyevaluationoftheomnipod5automatedinsulindeliverysystemoverthreemonthsofuseinchildrenwithtype1diabetest1d
AT desalvodanielj safetyevaluationoftheomnipod5automatedinsulindeliverysystemoverthreemonthsofuseinchildrenwithtype1diabetest1d
AT sherrjenniferl safetyevaluationoftheomnipod5automatedinsulindeliverysystemoverthreemonthsofuseinchildrenwithtype1diabetest1d
AT mehtasanjeevn safetyevaluationoftheomnipod5automatedinsulindeliverysystemoverthreemonthsofuseinchildrenwithtype1diabetest1d
AT laffellorim safetyevaluationoftheomnipod5automatedinsulindeliverysystemoverthreemonthsofuseinchildrenwithtype1diabetest1d
AT bhargavaanuj safetyevaluationoftheomnipod5automatedinsulindeliverysystemoverthreemonthsofuseinchildrenwithtype1diabetest1d
AT lytrangt safetyevaluationoftheomnipod5automatedinsulindeliverysystemoverthreemonthsofuseinchildrenwithtype1diabetest1d