Medtronic MiniMed 670G Auto Mode: Implications for Clinical Practice

Background: The Medtronic MiniMed 670G System was the first FDA approved hybrid closed loop system for users seven years of age and older. The system monitors glucose and can automatically adjust the delivery of long acting or basal insulin based on the user’s glucose reading while in Auto Mode. Pre...

Descripción completa

Detalles Bibliográficos
Autores principales: Dos Santos-Marinho, Jeanne, McGuirk, Liam, Puff, Amanda, Naparst, Monica, Alexandrov, Alice, Anselme, Philippe, Noto, Richard A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8090581/
http://dx.doi.org/10.1210/jendso/bvab048.1349
_version_ 1783687318005088256
author Dos Santos-Marinho, Jeanne
McGuirk, Liam
Puff, Amanda
Naparst, Monica
Alexandrov, Alice
Anselme, Philippe
Noto, Richard A
author_facet Dos Santos-Marinho, Jeanne
McGuirk, Liam
Puff, Amanda
Naparst, Monica
Alexandrov, Alice
Anselme, Philippe
Noto, Richard A
author_sort Dos Santos-Marinho, Jeanne
collection PubMed
description Background: The Medtronic MiniMed 670G System was the first FDA approved hybrid closed loop system for users seven years of age and older. The system monitors glucose and can automatically adjust the delivery of long acting or basal insulin based on the user’s glucose reading while in Auto Mode. Previous research has demonstrated that 670G Auto Mode use has improved glycemic control in patients (PTs) with Type 1 diabetes as young as 2 years of age and as old as 75 years of age compared to open loop Manual Mode. Objective: This retrospective study seeks to determine if the results of improved glycemic control, as evidenced by decreased HbA1c levels, can be replicated in real life/uncontrolled environments, when PTs are wearing the 670G system in Auto Mode. Methods: The medical records of PTs prescribed the 670G System at a pediatric endocrinology center were reviewed. PTs who did not use the system in Auto Mode were excluded. PTs who did not have HbA1c values before and at least 3 months after using the 670G system in Auto Mode were also excluded. HbA1c values were collected either as a serum sample at a local laboratory or a capillary sample at the center using Siemens DCA Vantage HbA1c Analyzer. 52 PTs aged 6-25 yrs met these criteria for analysis. Results: When analyzing the PTs as a whole, there was a significant decrease in HbA1c from 8.64% ± 1.51% to 7.81% ± 1.35% (p= 0.024). 63.5% of all PTs showed a decrease in HbA1c. 3.9% of PTs showed no change to their HbA1c. 32.7% of PTs showed an increase in HbA1c. Of those 63.5% of PTs who showed improved glycemic control, 51.5% had data in their charts to reflect their percentage of time in auto mode, which was an average of 54.32% ± 27.28%. There was no significant difference in HbA1c between males and females both prior (p=0.2) and post (p=0.1) treatment, nor was there a significant difference in the mean change of HbA1c between males and females (p=0.50). The PTs who were in auto mode greater than 25% of the time (n=15) showed significantly improved glycemic control with HbA1c levels decreasing from 8.13% ± 1.16% to 7.37% ± 0.58% (P= 0.04). The PTs who were in auto mode greater than 50% of the time (n=10), showed improved glycemic control with HbA1c levels decreasing from 7.87% ± 0.68% to 7.27% ± 0.46% (P= 0.046). There was a significant difference in the mean change of HbA1c between PTs whose adherence was known to be less than 25% (n=9) compared to those whose adherence was known to be greater than 25% (n=15). The difference in mean HbA1c prior treatment was not significant between these groups, yet the difference in mean HbA1c was significant post treatment. Conclusion: Our data demonstrates that the 670G system can significantly improve glycemic control in an uncontrolled environment. Adherence is an important factor in the outcome in this treatment modality. Bluetooth monitoring of patient blood sugar levels may significantly improve adherence and glycemic control.
format Online
Article
Text
id pubmed-8090581
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-80905812021-05-05 Medtronic MiniMed 670G Auto Mode: Implications for Clinical Practice Dos Santos-Marinho, Jeanne McGuirk, Liam Puff, Amanda Naparst, Monica Alexandrov, Alice Anselme, Philippe Noto, Richard A J Endocr Soc Pediatric Endocrinology Background: The Medtronic MiniMed 670G System was the first FDA approved hybrid closed loop system for users seven years of age and older. The system monitors glucose and can automatically adjust the delivery of long acting or basal insulin based on the user’s glucose reading while in Auto Mode. Previous research has demonstrated that 670G Auto Mode use has improved glycemic control in patients (PTs) with Type 1 diabetes as young as 2 years of age and as old as 75 years of age compared to open loop Manual Mode. Objective: This retrospective study seeks to determine if the results of improved glycemic control, as evidenced by decreased HbA1c levels, can be replicated in real life/uncontrolled environments, when PTs are wearing the 670G system in Auto Mode. Methods: The medical records of PTs prescribed the 670G System at a pediatric endocrinology center were reviewed. PTs who did not use the system in Auto Mode were excluded. PTs who did not have HbA1c values before and at least 3 months after using the 670G system in Auto Mode were also excluded. HbA1c values were collected either as a serum sample at a local laboratory or a capillary sample at the center using Siemens DCA Vantage HbA1c Analyzer. 52 PTs aged 6-25 yrs met these criteria for analysis. Results: When analyzing the PTs as a whole, there was a significant decrease in HbA1c from 8.64% ± 1.51% to 7.81% ± 1.35% (p= 0.024). 63.5% of all PTs showed a decrease in HbA1c. 3.9% of PTs showed no change to their HbA1c. 32.7% of PTs showed an increase in HbA1c. Of those 63.5% of PTs who showed improved glycemic control, 51.5% had data in their charts to reflect their percentage of time in auto mode, which was an average of 54.32% ± 27.28%. There was no significant difference in HbA1c between males and females both prior (p=0.2) and post (p=0.1) treatment, nor was there a significant difference in the mean change of HbA1c between males and females (p=0.50). The PTs who were in auto mode greater than 25% of the time (n=15) showed significantly improved glycemic control with HbA1c levels decreasing from 8.13% ± 1.16% to 7.37% ± 0.58% (P= 0.04). The PTs who were in auto mode greater than 50% of the time (n=10), showed improved glycemic control with HbA1c levels decreasing from 7.87% ± 0.68% to 7.27% ± 0.46% (P= 0.046). There was a significant difference in the mean change of HbA1c between PTs whose adherence was known to be less than 25% (n=9) compared to those whose adherence was known to be greater than 25% (n=15). The difference in mean HbA1c prior treatment was not significant between these groups, yet the difference in mean HbA1c was significant post treatment. Conclusion: Our data demonstrates that the 670G system can significantly improve glycemic control in an uncontrolled environment. Adherence is an important factor in the outcome in this treatment modality. Bluetooth monitoring of patient blood sugar levels may significantly improve adherence and glycemic control. Oxford University Press 2021-05-03 /pmc/articles/PMC8090581/ http://dx.doi.org/10.1210/jendso/bvab048.1349 Text en © The Author(s) 2021. Published by Oxford University Press on behalf of the Endocrine Society. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) ), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Pediatric Endocrinology
Dos Santos-Marinho, Jeanne
McGuirk, Liam
Puff, Amanda
Naparst, Monica
Alexandrov, Alice
Anselme, Philippe
Noto, Richard A
Medtronic MiniMed 670G Auto Mode: Implications for Clinical Practice
title Medtronic MiniMed 670G Auto Mode: Implications for Clinical Practice
title_full Medtronic MiniMed 670G Auto Mode: Implications for Clinical Practice
title_fullStr Medtronic MiniMed 670G Auto Mode: Implications for Clinical Practice
title_full_unstemmed Medtronic MiniMed 670G Auto Mode: Implications for Clinical Practice
title_short Medtronic MiniMed 670G Auto Mode: Implications for Clinical Practice
title_sort medtronic minimed 670g auto mode: implications for clinical practice
topic Pediatric Endocrinology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8090581/
http://dx.doi.org/10.1210/jendso/bvab048.1349
work_keys_str_mv AT dossantosmarinhojeanne medtronicminimed670gautomodeimplicationsforclinicalpractice
AT mcguirkliam medtronicminimed670gautomodeimplicationsforclinicalpractice
AT puffamanda medtronicminimed670gautomodeimplicationsforclinicalpractice
AT naparstmonica medtronicminimed670gautomodeimplicationsforclinicalpractice
AT alexandrovalice medtronicminimed670gautomodeimplicationsforclinicalpractice
AT anselmephilippe medtronicminimed670gautomodeimplicationsforclinicalpractice
AT notoricharda medtronicminimed670gautomodeimplicationsforclinicalpractice