Cargando…

Effect of Cathodic Arc Plasma Deposition on Shear Bond Strength between Palladium Cobalt Chromium Coated with Titanium Nitride and Titanium Aluminium Nitride with Ceramic

BACKGROUND: The success of esthetic ceramo-metal restoration is strongly influenced by its bond strength. The success of ceramo-metal restoration is subjective to its bond strength. AIM AND OBJECTIVES: The aim of this study is to evaluate the shear bond strength between palladium-based cobalt chromi...

Descripción completa

Detalles Bibliográficos
Autores principales: Prabhakar, Vaishnavi, Chidambaranathan, Ahila Singaravel, Balasubramanium, Muthukumar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8092097/
https://www.ncbi.nlm.nih.gov/pubmed/33967538
http://dx.doi.org/10.4103/ccd.ccd_79_20
_version_ 1783687590545719296
author Prabhakar, Vaishnavi
Chidambaranathan, Ahila Singaravel
Balasubramanium, Muthukumar
author_facet Prabhakar, Vaishnavi
Chidambaranathan, Ahila Singaravel
Balasubramanium, Muthukumar
author_sort Prabhakar, Vaishnavi
collection PubMed
description BACKGROUND: The success of esthetic ceramo-metal restoration is strongly influenced by its bond strength. The success of ceramo-metal restoration is subjective to its bond strength. AIM AND OBJECTIVES: The aim of this study is to evaluate the shear bond strength between palladium-based cobalt chromium (Co-Cr) alloy coated with titanium nitride (TiNi) and titanium aluminum nitride with feldspathic ceramics. MATERIALS AND METHODS: According to the International Organization for standardization 9693; technical report 1,140,640 samples were prepared using Palladium-based Co-Cr alloy with ×4 vertical projection resting on 5 mm diameter base. The samples were divided into Group: A (control), Group: B (Sandblasted), Group: C (TiNi coated), and Group: D (titanium aluminum nitride coated by cathodic arc plasma deposition, following which feldspathic ceramic application was performed. Shear bond test was performed using universal testing machine and surface analysis was performed using scanning electron microscope. RESULTS: The mean shear bond strength for Group A was 172.994 ± 3.739 N, Group B 209.485 ± 5.913 N, Group C 176.536 ± 4.780 N, and Group D 260.576 ± 16.351 N. Comparison within the groups was made using one-way ANOVA, and multiple group comparisons were made using Tukey's honestly significant difference Post hoc test where the P < 0.001was considered statistically significant. CONCLUSION: Palladium based Co-Cr alloy coated with titanium aluminum nitride by cathodic plasma arc deposition showed maximum shear bond strength with feldspathic ceramic compared to noncoated, sandblasted, and TiNi coated alloy.
format Online
Article
Text
id pubmed-8092097
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-80920972021-05-06 Effect of Cathodic Arc Plasma Deposition on Shear Bond Strength between Palladium Cobalt Chromium Coated with Titanium Nitride and Titanium Aluminium Nitride with Ceramic Prabhakar, Vaishnavi Chidambaranathan, Ahila Singaravel Balasubramanium, Muthukumar Contemp Clin Dent Original Article BACKGROUND: The success of esthetic ceramo-metal restoration is strongly influenced by its bond strength. The success of ceramo-metal restoration is subjective to its bond strength. AIM AND OBJECTIVES: The aim of this study is to evaluate the shear bond strength between palladium-based cobalt chromium (Co-Cr) alloy coated with titanium nitride (TiNi) and titanium aluminum nitride with feldspathic ceramics. MATERIALS AND METHODS: According to the International Organization for standardization 9693; technical report 1,140,640 samples were prepared using Palladium-based Co-Cr alloy with ×4 vertical projection resting on 5 mm diameter base. The samples were divided into Group: A (control), Group: B (Sandblasted), Group: C (TiNi coated), and Group: D (titanium aluminum nitride coated by cathodic arc plasma deposition, following which feldspathic ceramic application was performed. Shear bond test was performed using universal testing machine and surface analysis was performed using scanning electron microscope. RESULTS: The mean shear bond strength for Group A was 172.994 ± 3.739 N, Group B 209.485 ± 5.913 N, Group C 176.536 ± 4.780 N, and Group D 260.576 ± 16.351 N. Comparison within the groups was made using one-way ANOVA, and multiple group comparisons were made using Tukey's honestly significant difference Post hoc test where the P < 0.001was considered statistically significant. CONCLUSION: Palladium based Co-Cr alloy coated with titanium aluminum nitride by cathodic plasma arc deposition showed maximum shear bond strength with feldspathic ceramic compared to noncoated, sandblasted, and TiNi coated alloy. Wolters Kluwer - Medknow 2021 2021-03-20 /pmc/articles/PMC8092097/ /pubmed/33967538 http://dx.doi.org/10.4103/ccd.ccd_79_20 Text en Copyright: © 2021 Contemporary Clinical Dentistry https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Prabhakar, Vaishnavi
Chidambaranathan, Ahila Singaravel
Balasubramanium, Muthukumar
Effect of Cathodic Arc Plasma Deposition on Shear Bond Strength between Palladium Cobalt Chromium Coated with Titanium Nitride and Titanium Aluminium Nitride with Ceramic
title Effect of Cathodic Arc Plasma Deposition on Shear Bond Strength between Palladium Cobalt Chromium Coated with Titanium Nitride and Titanium Aluminium Nitride with Ceramic
title_full Effect of Cathodic Arc Plasma Deposition on Shear Bond Strength between Palladium Cobalt Chromium Coated with Titanium Nitride and Titanium Aluminium Nitride with Ceramic
title_fullStr Effect of Cathodic Arc Plasma Deposition on Shear Bond Strength between Palladium Cobalt Chromium Coated with Titanium Nitride and Titanium Aluminium Nitride with Ceramic
title_full_unstemmed Effect of Cathodic Arc Plasma Deposition on Shear Bond Strength between Palladium Cobalt Chromium Coated with Titanium Nitride and Titanium Aluminium Nitride with Ceramic
title_short Effect of Cathodic Arc Plasma Deposition on Shear Bond Strength between Palladium Cobalt Chromium Coated with Titanium Nitride and Titanium Aluminium Nitride with Ceramic
title_sort effect of cathodic arc plasma deposition on shear bond strength between palladium cobalt chromium coated with titanium nitride and titanium aluminium nitride with ceramic
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8092097/
https://www.ncbi.nlm.nih.gov/pubmed/33967538
http://dx.doi.org/10.4103/ccd.ccd_79_20
work_keys_str_mv AT prabhakarvaishnavi effectofcathodicarcplasmadepositiononshearbondstrengthbetweenpalladiumcobaltchromiumcoatedwithtitaniumnitrideandtitaniumaluminiumnitridewithceramic
AT chidambaranathanahilasingaravel effectofcathodicarcplasmadepositiononshearbondstrengthbetweenpalladiumcobaltchromiumcoatedwithtitaniumnitrideandtitaniumaluminiumnitridewithceramic
AT balasubramaniummuthukumar effectofcathodicarcplasmadepositiononshearbondstrengthbetweenpalladiumcobaltchromiumcoatedwithtitaniumnitrideandtitaniumaluminiumnitridewithceramic