A Low-Cost Method to Assess the Performance of Surface Guidance Imaging Systems at Non-Zero Couch Angles

A procedure is presented to assess performance at non-zero couch angles and perform routine quality assurance (QA) on surface-guided radiotherapy (SGRT) imaging systems used for stereotactic radiosurgery (SRS). A low-cost anthropomorphic phantom was used to assess the system under patient-like condi...

Descripción completa

Detalles Bibliográficos
Autores principales: Covington, Elizabeth L, Popple, Richard A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8093097/
https://www.ncbi.nlm.nih.gov/pubmed/33959456
http://dx.doi.org/10.7759/cureus.14278
_version_ 1783687742955192320
author Covington, Elizabeth L
Popple, Richard A
author_facet Covington, Elizabeth L
Popple, Richard A
author_sort Covington, Elizabeth L
collection PubMed
description A procedure is presented to assess performance at non-zero couch angles and perform routine quality assurance (QA) on surface-guided radiotherapy (SGRT) imaging systems used for stereotactic radiosurgery (SRS). A low-cost anthropomorphic phantom was used to assess the system under patient-like conditions. The phantom is embedded with a tungsten ball bearing (BB) to facilitate the use of surface imaging (SI) with concurrent megavoltage (MV) imaging to cross-compare and validate SI-reported offsets. Data analysis is done via in-house software that utilized the SGRT system’s log files for automated analysis. This procedure enables users to assess and inter-compare MV-reported offsets with their SGRT system. The analysis provides SGRT system residual error so that users are aware of inherent offsets present in addition to increases in translational offsets due to couch walkout. The procedure was validated with two commercial SGRT systems. The procedure can be used with any surface imaging system and linear accelerator system.
format Online
Article
Text
id pubmed-8093097
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-80930972021-05-05 A Low-Cost Method to Assess the Performance of Surface Guidance Imaging Systems at Non-Zero Couch Angles Covington, Elizabeth L Popple, Richard A Cureus Medical Physics A procedure is presented to assess performance at non-zero couch angles and perform routine quality assurance (QA) on surface-guided radiotherapy (SGRT) imaging systems used for stereotactic radiosurgery (SRS). A low-cost anthropomorphic phantom was used to assess the system under patient-like conditions. The phantom is embedded with a tungsten ball bearing (BB) to facilitate the use of surface imaging (SI) with concurrent megavoltage (MV) imaging to cross-compare and validate SI-reported offsets. Data analysis is done via in-house software that utilized the SGRT system’s log files for automated analysis. This procedure enables users to assess and inter-compare MV-reported offsets with their SGRT system. The analysis provides SGRT system residual error so that users are aware of inherent offsets present in addition to increases in translational offsets due to couch walkout. The procedure was validated with two commercial SGRT systems. The procedure can be used with any surface imaging system and linear accelerator system. Cureus 2021-04-03 /pmc/articles/PMC8093097/ /pubmed/33959456 http://dx.doi.org/10.7759/cureus.14278 Text en Copyright © 2021, Covington et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Medical Physics
Covington, Elizabeth L
Popple, Richard A
A Low-Cost Method to Assess the Performance of Surface Guidance Imaging Systems at Non-Zero Couch Angles
title A Low-Cost Method to Assess the Performance of Surface Guidance Imaging Systems at Non-Zero Couch Angles
title_full A Low-Cost Method to Assess the Performance of Surface Guidance Imaging Systems at Non-Zero Couch Angles
title_fullStr A Low-Cost Method to Assess the Performance of Surface Guidance Imaging Systems at Non-Zero Couch Angles
title_full_unstemmed A Low-Cost Method to Assess the Performance of Surface Guidance Imaging Systems at Non-Zero Couch Angles
title_short A Low-Cost Method to Assess the Performance of Surface Guidance Imaging Systems at Non-Zero Couch Angles
title_sort low-cost method to assess the performance of surface guidance imaging systems at non-zero couch angles
topic Medical Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8093097/
https://www.ncbi.nlm.nih.gov/pubmed/33959456
http://dx.doi.org/10.7759/cureus.14278
work_keys_str_mv AT covingtonelizabethl alowcostmethodtoassesstheperformanceofsurfaceguidanceimagingsystemsatnonzerocouchangles
AT popplericharda alowcostmethodtoassesstheperformanceofsurfaceguidanceimagingsystemsatnonzerocouchangles
AT covingtonelizabethl lowcostmethodtoassesstheperformanceofsurfaceguidanceimagingsystemsatnonzerocouchangles
AT popplericharda lowcostmethodtoassesstheperformanceofsurfaceguidanceimagingsystemsatnonzerocouchangles