Cargando…

A Retrospective Evaluation and Review of Outcomes for Single- and Multilevel ACDF With a Zero-Profile Stand-Alone Cage Device With Integrated Instrumentation

This study aimed to assess clinical and radiological outcomes associated with zero-profile stand-alone cages with instrumentation used for single- and multilevel anterior cervical discectomy and fusion (ACDF) operations. Many plate-cage ACDF systems have proven to be successful in producing high fus...

Descripción completa

Detalles Bibliográficos
Autores principales: Khalifeh, Kareem, Faulkner, Jordan E, Hara, Junko, Ozgur, Burak
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8093780/
https://www.ncbi.nlm.nih.gov/pubmed/33959461
http://dx.doi.org/10.7759/cureus.14283
_version_ 1783687886971863040
author Khalifeh, Kareem
Faulkner, Jordan E
Hara, Junko
Ozgur, Burak
author_facet Khalifeh, Kareem
Faulkner, Jordan E
Hara, Junko
Ozgur, Burak
author_sort Khalifeh, Kareem
collection PubMed
description This study aimed to assess clinical and radiological outcomes associated with zero-profile stand-alone cages with instrumentation used for single- and multilevel anterior cervical discectomy and fusion (ACDF) operations. Many plate-cage ACDF systems have proven to be successful in producing high fusion rates and positive clinical outcomes. However, the anterior plating in traditional systems has been associated with complications such as dysphagia and mechanical accidents. A total of 190 patients underwent single- or multilevel ACDF surgeries with zero-profile polyetheretherketone cages containing integrated titanium instrumentation and screw fixation (one-level, n=31; two-level, n=65; three-level, n=71; four-level, n=23). Demographic information such as age and smoking status as well as postoperative outcomes were collected and analysed. Out of the 190 patients who underwent ACDF surgeries with a zero-profile stand-alone cage, none experienced any conditions or infections, and zero were readmitted postoperatively. Although traditional plate-cage systems yield high fusion rates in ACDF surgeries, zero-profile systems with integrated fixation have showcased impressive clinical and radiographic results in both single- and multilevel operations.
format Online
Article
Text
id pubmed-8093780
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-80937802021-05-05 A Retrospective Evaluation and Review of Outcomes for Single- and Multilevel ACDF With a Zero-Profile Stand-Alone Cage Device With Integrated Instrumentation Khalifeh, Kareem Faulkner, Jordan E Hara, Junko Ozgur, Burak Cureus Neurosurgery This study aimed to assess clinical and radiological outcomes associated with zero-profile stand-alone cages with instrumentation used for single- and multilevel anterior cervical discectomy and fusion (ACDF) operations. Many plate-cage ACDF systems have proven to be successful in producing high fusion rates and positive clinical outcomes. However, the anterior plating in traditional systems has been associated with complications such as dysphagia and mechanical accidents. A total of 190 patients underwent single- or multilevel ACDF surgeries with zero-profile polyetheretherketone cages containing integrated titanium instrumentation and screw fixation (one-level, n=31; two-level, n=65; three-level, n=71; four-level, n=23). Demographic information such as age and smoking status as well as postoperative outcomes were collected and analysed. Out of the 190 patients who underwent ACDF surgeries with a zero-profile stand-alone cage, none experienced any conditions or infections, and zero were readmitted postoperatively. Although traditional plate-cage systems yield high fusion rates in ACDF surgeries, zero-profile systems with integrated fixation have showcased impressive clinical and radiographic results in both single- and multilevel operations. Cureus 2021-04-03 /pmc/articles/PMC8093780/ /pubmed/33959461 http://dx.doi.org/10.7759/cureus.14283 Text en Copyright © 2021, Khalifeh et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Neurosurgery
Khalifeh, Kareem
Faulkner, Jordan E
Hara, Junko
Ozgur, Burak
A Retrospective Evaluation and Review of Outcomes for Single- and Multilevel ACDF With a Zero-Profile Stand-Alone Cage Device With Integrated Instrumentation
title A Retrospective Evaluation and Review of Outcomes for Single- and Multilevel ACDF With a Zero-Profile Stand-Alone Cage Device With Integrated Instrumentation
title_full A Retrospective Evaluation and Review of Outcomes for Single- and Multilevel ACDF With a Zero-Profile Stand-Alone Cage Device With Integrated Instrumentation
title_fullStr A Retrospective Evaluation and Review of Outcomes for Single- and Multilevel ACDF With a Zero-Profile Stand-Alone Cage Device With Integrated Instrumentation
title_full_unstemmed A Retrospective Evaluation and Review of Outcomes for Single- and Multilevel ACDF With a Zero-Profile Stand-Alone Cage Device With Integrated Instrumentation
title_short A Retrospective Evaluation and Review of Outcomes for Single- and Multilevel ACDF With a Zero-Profile Stand-Alone Cage Device With Integrated Instrumentation
title_sort retrospective evaluation and review of outcomes for single- and multilevel acdf with a zero-profile stand-alone cage device with integrated instrumentation
topic Neurosurgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8093780/
https://www.ncbi.nlm.nih.gov/pubmed/33959461
http://dx.doi.org/10.7759/cureus.14283
work_keys_str_mv AT khalifehkareem aretrospectiveevaluationandreviewofoutcomesforsingleandmultilevelacdfwithazeroprofilestandalonecagedevicewithintegratedinstrumentation
AT faulknerjordane aretrospectiveevaluationandreviewofoutcomesforsingleandmultilevelacdfwithazeroprofilestandalonecagedevicewithintegratedinstrumentation
AT harajunko aretrospectiveevaluationandreviewofoutcomesforsingleandmultilevelacdfwithazeroprofilestandalonecagedevicewithintegratedinstrumentation
AT ozgurburak aretrospectiveevaluationandreviewofoutcomesforsingleandmultilevelacdfwithazeroprofilestandalonecagedevicewithintegratedinstrumentation
AT khalifehkareem retrospectiveevaluationandreviewofoutcomesforsingleandmultilevelacdfwithazeroprofilestandalonecagedevicewithintegratedinstrumentation
AT faulknerjordane retrospectiveevaluationandreviewofoutcomesforsingleandmultilevelacdfwithazeroprofilestandalonecagedevicewithintegratedinstrumentation
AT harajunko retrospectiveevaluationandreviewofoutcomesforsingleandmultilevelacdfwithazeroprofilestandalonecagedevicewithintegratedinstrumentation
AT ozgurburak retrospectiveevaluationandreviewofoutcomesforsingleandmultilevelacdfwithazeroprofilestandalonecagedevicewithintegratedinstrumentation