Cargando…

Balancing the Loudness in Speech Processors and Contralateral Hearing Aids in Users of Unilateral Cochlear Implants

Introduction  The use of cochlear implants and hearing aids (bimodal) has been growing with the expansion of the indication for them, and it is important to ensure protocols so that there is a balance of the loudness regarding the two devices. Objective  To evaluate if the limited complex sounds pre...

Descripción completa

Detalles Bibliográficos
Autores principales: Magalhães, Ana Tereza Matos, Carvalho, Amanda, Tsuji, Robinson Koji, Bento, Ricardo Ferreira, Goffi-Gomez, Maria Valéria Schmidt
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Thieme Revinter Publicações Ltda. 2021
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8096504/
https://www.ncbi.nlm.nih.gov/pubmed/33968226
http://dx.doi.org/10.1055/s-0040-1712482
_version_ 1783688173229965312
author Magalhães, Ana Tereza Matos
Carvalho, Amanda
Tsuji, Robinson Koji
Bento, Ricardo Ferreira
Goffi-Gomez, Maria Valéria Schmidt
author_facet Magalhães, Ana Tereza Matos
Carvalho, Amanda
Tsuji, Robinson Koji
Bento, Ricardo Ferreira
Goffi-Gomez, Maria Valéria Schmidt
author_sort Magalhães, Ana Tereza Matos
collection PubMed
description Introduction  The use of cochlear implants and hearing aids (bimodal) has been growing with the expansion of the indication for them, and it is important to ensure protocols so that there is a balance of the loudness regarding the two devices. Objective  To evaluate if the limited complex sounds present in the frequency bands of the current devices enable the balance of the loudness in adult users of bimodal stimulation, and to analyze if speech recognition improves after balancing. Methods  A prospective cross-sectional study with convenience sampling. The sample was composed of 25 adults who had used either a cochlear implant for at least 6 months or a contralateral hearing aid, with a mean age of 46 years. The balancing of the loudness was performed in an acoustic room with the computer's sound box (0° azimuth at 70 dB SPL). The instrumental sounds were filtered through eight different frequency bands. The patients used both hearing devices and were asked if the sound was perceived to be louder in one of the ears or centrally. The speech test was evaluated with sentence silence (65 dB SPL) and/or noise signal ratio of 0 dB/+ 10 dB in free field at 0° azimuth, before and after balancing. Results : Out of the 25 patients, 5 failed to achieve balance at every tested frequency, and 3 achieved balance at almost every frequency, except 8 kHz. There was a significant difference between the speech recognition test only in silence before and after balancing. Conclusion : Most patients achieved sound equalization at all evaluated frequencies under the complex-sound protocol. Additionally, most patients experienced improved speech recognition after balancing.
format Online
Article
Text
id pubmed-8096504
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Thieme Revinter Publicações Ltda.
record_format MEDLINE/PubMed
spelling pubmed-80965042021-05-06 Balancing the Loudness in Speech Processors and Contralateral Hearing Aids in Users of Unilateral Cochlear Implants Magalhães, Ana Tereza Matos Carvalho, Amanda Tsuji, Robinson Koji Bento, Ricardo Ferreira Goffi-Gomez, Maria Valéria Schmidt Int Arch Otorhinolaryngol Introduction  The use of cochlear implants and hearing aids (bimodal) has been growing with the expansion of the indication for them, and it is important to ensure protocols so that there is a balance of the loudness regarding the two devices. Objective  To evaluate if the limited complex sounds present in the frequency bands of the current devices enable the balance of the loudness in adult users of bimodal stimulation, and to analyze if speech recognition improves after balancing. Methods  A prospective cross-sectional study with convenience sampling. The sample was composed of 25 adults who had used either a cochlear implant for at least 6 months or a contralateral hearing aid, with a mean age of 46 years. The balancing of the loudness was performed in an acoustic room with the computer's sound box (0° azimuth at 70 dB SPL). The instrumental sounds were filtered through eight different frequency bands. The patients used both hearing devices and were asked if the sound was perceived to be louder in one of the ears or centrally. The speech test was evaluated with sentence silence (65 dB SPL) and/or noise signal ratio of 0 dB/+ 10 dB in free field at 0° azimuth, before and after balancing. Results : Out of the 25 patients, 5 failed to achieve balance at every tested frequency, and 3 achieved balance at almost every frequency, except 8 kHz. There was a significant difference between the speech recognition test only in silence before and after balancing. Conclusion : Most patients achieved sound equalization at all evaluated frequencies under the complex-sound protocol. Additionally, most patients experienced improved speech recognition after balancing. Thieme Revinter Publicações Ltda. 2021-04 2020-06-23 /pmc/articles/PMC8096504/ /pubmed/33968226 http://dx.doi.org/10.1055/s-0040-1712482 Text en Fundação Otorrinolaringologia. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commecial purposes, or adapted, remixed, transformed or built upon. ( https://creativecommons.org/licenses/by-nc-nd/4.0/ ) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited.
spellingShingle Magalhães, Ana Tereza Matos
Carvalho, Amanda
Tsuji, Robinson Koji
Bento, Ricardo Ferreira
Goffi-Gomez, Maria Valéria Schmidt
Balancing the Loudness in Speech Processors and Contralateral Hearing Aids in Users of Unilateral Cochlear Implants
title Balancing the Loudness in Speech Processors and Contralateral Hearing Aids in Users of Unilateral Cochlear Implants
title_full Balancing the Loudness in Speech Processors and Contralateral Hearing Aids in Users of Unilateral Cochlear Implants
title_fullStr Balancing the Loudness in Speech Processors and Contralateral Hearing Aids in Users of Unilateral Cochlear Implants
title_full_unstemmed Balancing the Loudness in Speech Processors and Contralateral Hearing Aids in Users of Unilateral Cochlear Implants
title_short Balancing the Loudness in Speech Processors and Contralateral Hearing Aids in Users of Unilateral Cochlear Implants
title_sort balancing the loudness in speech processors and contralateral hearing aids in users of unilateral cochlear implants
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8096504/
https://www.ncbi.nlm.nih.gov/pubmed/33968226
http://dx.doi.org/10.1055/s-0040-1712482
work_keys_str_mv AT magalhaesanaterezamatos balancingtheloudnessinspeechprocessorsandcontralateralhearingaidsinusersofunilateralcochlearimplants
AT carvalhoamanda balancingtheloudnessinspeechprocessorsandcontralateralhearingaidsinusersofunilateralcochlearimplants
AT tsujirobinsonkoji balancingtheloudnessinspeechprocessorsandcontralateralhearingaidsinusersofunilateralcochlearimplants
AT bentoricardoferreira balancingtheloudnessinspeechprocessorsandcontralateralhearingaidsinusersofunilateralcochlearimplants
AT goffigomezmariavaleriaschmidt balancingtheloudnessinspeechprocessorsandcontralateralhearingaidsinusersofunilateralcochlearimplants