Improvement of multisource localization of magnetic particles in an animal

In this simulation work, the linearized Bregman iterative algorithm was applied to solve the magnetic source distribution problem of a magnetic particle imaging (MPI) system for small animals. MPI system can apply an excitation magnetic field, and the induced magnetic field from the magnetic nanopar...

Descripción completa

Detalles Bibliográficos
Autores principales: Lin, Chin-Wei, Liao, Shu-Hsien, Huang, Han-Sheng, Wang, Li-Min, Chen, Jyh-Horng, Su, Chia-Hao, Chen, Kuen-Lin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8100150/
https://www.ncbi.nlm.nih.gov/pubmed/33953248
http://dx.doi.org/10.1038/s41598-021-88847-8
_version_ 1783688719897722880
author Lin, Chin-Wei
Liao, Shu-Hsien
Huang, Han-Sheng
Wang, Li-Min
Chen, Jyh-Horng
Su, Chia-Hao
Chen, Kuen-Lin
author_facet Lin, Chin-Wei
Liao, Shu-Hsien
Huang, Han-Sheng
Wang, Li-Min
Chen, Jyh-Horng
Su, Chia-Hao
Chen, Kuen-Lin
author_sort Lin, Chin-Wei
collection PubMed
description In this simulation work, the linearized Bregman iterative algorithm was applied to solve the magnetic source distribution problem of a magnetic particle imaging (MPI) system for small animals. MPI system can apply an excitation magnetic field, and the induced magnetic field from the magnetic nanoparticles (MNPs) can be detected by the sensors of MPI system. With a gaussian distribution source at the upper side of the mouse brain, sensors set above the mouse brain and the constant excitation magnetic field, the average deviation of the calculated source distribution from the multiplane scanning along the axis away from the mouse brain and the closest plane scanning are 2.78 × 10(–3) and 2.84 × 10(–3) respectively. The simulated result showed that combination of multiplane scanning hardly improves the accuracy of the source localization. In addition, a gradient scan method was developed that uses gradient magnetic field to scan the mouse brain. The position of the maximum of the lead field matrix will be controlled by the gradient field. With a set up gaussian distribution source at the bottom of the mouse brain, the average deviation of the calculated source distribution from the gradient scan method and the constant field are 4.42 × 10(–2) and 5.05 × 10(–2). The location error from the two method are 2.24 × 10(–1) cm and 3.61 × 10(–1) cm. The simulation showed that this method can improve the accuracy compared to constant field when the source is away from the sensor and having a potential for application.
format Online
Article
Text
id pubmed-8100150
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-81001502021-05-07 Improvement of multisource localization of magnetic particles in an animal Lin, Chin-Wei Liao, Shu-Hsien Huang, Han-Sheng Wang, Li-Min Chen, Jyh-Horng Su, Chia-Hao Chen, Kuen-Lin Sci Rep Article In this simulation work, the linearized Bregman iterative algorithm was applied to solve the magnetic source distribution problem of a magnetic particle imaging (MPI) system for small animals. MPI system can apply an excitation magnetic field, and the induced magnetic field from the magnetic nanoparticles (MNPs) can be detected by the sensors of MPI system. With a gaussian distribution source at the upper side of the mouse brain, sensors set above the mouse brain and the constant excitation magnetic field, the average deviation of the calculated source distribution from the multiplane scanning along the axis away from the mouse brain and the closest plane scanning are 2.78 × 10(–3) and 2.84 × 10(–3) respectively. The simulated result showed that combination of multiplane scanning hardly improves the accuracy of the source localization. In addition, a gradient scan method was developed that uses gradient magnetic field to scan the mouse brain. The position of the maximum of the lead field matrix will be controlled by the gradient field. With a set up gaussian distribution source at the bottom of the mouse brain, the average deviation of the calculated source distribution from the gradient scan method and the constant field are 4.42 × 10(–2) and 5.05 × 10(–2). The location error from the two method are 2.24 × 10(–1) cm and 3.61 × 10(–1) cm. The simulation showed that this method can improve the accuracy compared to constant field when the source is away from the sensor and having a potential for application. Nature Publishing Group UK 2021-05-05 /pmc/articles/PMC8100150/ /pubmed/33953248 http://dx.doi.org/10.1038/s41598-021-88847-8 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Lin, Chin-Wei
Liao, Shu-Hsien
Huang, Han-Sheng
Wang, Li-Min
Chen, Jyh-Horng
Su, Chia-Hao
Chen, Kuen-Lin
Improvement of multisource localization of magnetic particles in an animal
title Improvement of multisource localization of magnetic particles in an animal
title_full Improvement of multisource localization of magnetic particles in an animal
title_fullStr Improvement of multisource localization of magnetic particles in an animal
title_full_unstemmed Improvement of multisource localization of magnetic particles in an animal
title_short Improvement of multisource localization of magnetic particles in an animal
title_sort improvement of multisource localization of magnetic particles in an animal
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8100150/
https://www.ncbi.nlm.nih.gov/pubmed/33953248
http://dx.doi.org/10.1038/s41598-021-88847-8
work_keys_str_mv AT linchinwei improvementofmultisourcelocalizationofmagneticparticlesinananimal
AT liaoshuhsien improvementofmultisourcelocalizationofmagneticparticlesinananimal
AT huanghansheng improvementofmultisourcelocalizationofmagneticparticlesinananimal
AT wanglimin improvementofmultisourcelocalizationofmagneticparticlesinananimal
AT chenjyhhorng improvementofmultisourcelocalizationofmagneticparticlesinananimal
AT suchiahao improvementofmultisourcelocalizationofmagneticparticlesinananimal
AT chenkuenlin improvementofmultisourcelocalizationofmagneticparticlesinananimal