Cargando…
Improvement of multisource localization of magnetic particles in an animal
In this simulation work, the linearized Bregman iterative algorithm was applied to solve the magnetic source distribution problem of a magnetic particle imaging (MPI) system for small animals. MPI system can apply an excitation magnetic field, and the induced magnetic field from the magnetic nanopar...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8100150/ https://www.ncbi.nlm.nih.gov/pubmed/33953248 http://dx.doi.org/10.1038/s41598-021-88847-8 |
_version_ | 1783688719897722880 |
---|---|
author | Lin, Chin-Wei Liao, Shu-Hsien Huang, Han-Sheng Wang, Li-Min Chen, Jyh-Horng Su, Chia-Hao Chen, Kuen-Lin |
author_facet | Lin, Chin-Wei Liao, Shu-Hsien Huang, Han-Sheng Wang, Li-Min Chen, Jyh-Horng Su, Chia-Hao Chen, Kuen-Lin |
author_sort | Lin, Chin-Wei |
collection | PubMed |
description | In this simulation work, the linearized Bregman iterative algorithm was applied to solve the magnetic source distribution problem of a magnetic particle imaging (MPI) system for small animals. MPI system can apply an excitation magnetic field, and the induced magnetic field from the magnetic nanoparticles (MNPs) can be detected by the sensors of MPI system. With a gaussian distribution source at the upper side of the mouse brain, sensors set above the mouse brain and the constant excitation magnetic field, the average deviation of the calculated source distribution from the multiplane scanning along the axis away from the mouse brain and the closest plane scanning are 2.78 × 10(–3) and 2.84 × 10(–3) respectively. The simulated result showed that combination of multiplane scanning hardly improves the accuracy of the source localization. In addition, a gradient scan method was developed that uses gradient magnetic field to scan the mouse brain. The position of the maximum of the lead field matrix will be controlled by the gradient field. With a set up gaussian distribution source at the bottom of the mouse brain, the average deviation of the calculated source distribution from the gradient scan method and the constant field are 4.42 × 10(–2) and 5.05 × 10(–2). The location error from the two method are 2.24 × 10(–1) cm and 3.61 × 10(–1) cm. The simulation showed that this method can improve the accuracy compared to constant field when the source is away from the sensor and having a potential for application. |
format | Online Article Text |
id | pubmed-8100150 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-81001502021-05-07 Improvement of multisource localization of magnetic particles in an animal Lin, Chin-Wei Liao, Shu-Hsien Huang, Han-Sheng Wang, Li-Min Chen, Jyh-Horng Su, Chia-Hao Chen, Kuen-Lin Sci Rep Article In this simulation work, the linearized Bregman iterative algorithm was applied to solve the magnetic source distribution problem of a magnetic particle imaging (MPI) system for small animals. MPI system can apply an excitation magnetic field, and the induced magnetic field from the magnetic nanoparticles (MNPs) can be detected by the sensors of MPI system. With a gaussian distribution source at the upper side of the mouse brain, sensors set above the mouse brain and the constant excitation magnetic field, the average deviation of the calculated source distribution from the multiplane scanning along the axis away from the mouse brain and the closest plane scanning are 2.78 × 10(–3) and 2.84 × 10(–3) respectively. The simulated result showed that combination of multiplane scanning hardly improves the accuracy of the source localization. In addition, a gradient scan method was developed that uses gradient magnetic field to scan the mouse brain. The position of the maximum of the lead field matrix will be controlled by the gradient field. With a set up gaussian distribution source at the bottom of the mouse brain, the average deviation of the calculated source distribution from the gradient scan method and the constant field are 4.42 × 10(–2) and 5.05 × 10(–2). The location error from the two method are 2.24 × 10(–1) cm and 3.61 × 10(–1) cm. The simulation showed that this method can improve the accuracy compared to constant field when the source is away from the sensor and having a potential for application. Nature Publishing Group UK 2021-05-05 /pmc/articles/PMC8100150/ /pubmed/33953248 http://dx.doi.org/10.1038/s41598-021-88847-8 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Lin, Chin-Wei Liao, Shu-Hsien Huang, Han-Sheng Wang, Li-Min Chen, Jyh-Horng Su, Chia-Hao Chen, Kuen-Lin Improvement of multisource localization of magnetic particles in an animal |
title | Improvement of multisource localization of magnetic particles in an animal |
title_full | Improvement of multisource localization of magnetic particles in an animal |
title_fullStr | Improvement of multisource localization of magnetic particles in an animal |
title_full_unstemmed | Improvement of multisource localization of magnetic particles in an animal |
title_short | Improvement of multisource localization of magnetic particles in an animal |
title_sort | improvement of multisource localization of magnetic particles in an animal |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8100150/ https://www.ncbi.nlm.nih.gov/pubmed/33953248 http://dx.doi.org/10.1038/s41598-021-88847-8 |
work_keys_str_mv | AT linchinwei improvementofmultisourcelocalizationofmagneticparticlesinananimal AT liaoshuhsien improvementofmultisourcelocalizationofmagneticparticlesinananimal AT huanghansheng improvementofmultisourcelocalizationofmagneticparticlesinananimal AT wanglimin improvementofmultisourcelocalizationofmagneticparticlesinananimal AT chenjyhhorng improvementofmultisourcelocalizationofmagneticparticlesinananimal AT suchiahao improvementofmultisourcelocalizationofmagneticparticlesinananimal AT chenkuenlin improvementofmultisourcelocalizationofmagneticparticlesinananimal |