Cargando…
Determinants of peripapillary retinal nerve fiber layer’s grayscale value in normal eyes by spectral domain optical coherence tomography
To determine and evaluate the distribution, variation, and determinants of peripapillary retinal nerve fiber layer (pRNFL) grayscale value with spectral-domain optical coherence tomography (SD-OCT) in normal eyes. In this cross-sectional study, three hundred ninety-seven normal eyes from 397 healthy...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8100177/ https://www.ncbi.nlm.nih.gov/pubmed/33953227 http://dx.doi.org/10.1038/s41598-021-88604-x |
_version_ | 1783688726152478720 |
---|---|
author | Xie, Xiaolin Chen, Binyao Yang, Jianling Huang, Chukai Qiu, Kunliang Zheng, Ce Zhang, Mingzhi |
author_facet | Xie, Xiaolin Chen, Binyao Yang, Jianling Huang, Chukai Qiu, Kunliang Zheng, Ce Zhang, Mingzhi |
author_sort | Xie, Xiaolin |
collection | PubMed |
description | To determine and evaluate the distribution, variation, and determinants of peripapillary retinal nerve fiber layer (pRNFL) grayscale value with spectral-domain optical coherence tomography (SD-OCT) in normal eyes. In this cross-sectional study, three hundred ninety-seven normal eyes from 397 healthy Chinese adults aged 18–80 were consecutively recruited from a tertiary eye care center. An SD-OCT instrument took pRNFL imaging. We used a customized software to measure pRNFL parameters, including thickness and grayscale value. Univariable and multiple linear regression analyses were performed to examine the relationship between pRNFL grayscale value with ocular (e.g., axial length [A.L.], spherical equivalent [S.E.], intraocular pressure [IOP]), and systemic (e.g., age, sex) factors. A total of 397 eyes from 397 healthy subjects were included in the final analysis with mean (± SD) age 44.63 ± 16.43 years (range 18–80 years) and 196 (49.4%) males. The mean average of pRNFL grayscale value and thickness 164.82 ± 5.69 and 106.68 ± 8.89 μm, respectively. pRNFL grayscale value in nasal sectors (163.26 ± 9.31) was significantly lower comparing those in all other five sectors (all with p < 0.001)]. In multivariable analysis, average pRNFL grayscale value was independently correlated to older age (β = − 0.053, p = 0.002), longer axial length (β = − 0.664, p = 0.003), lower RPE grayscale value (β = 0.372, p < 0.001) and lower ImageQ (β = 0.658, p < 0.001). In this study, we provided normative SD-OCT data on the pRNFL grayscale value profile in nonglaucomatous eyes. Lower average pRNFL grayscale value was independently correlated to older age, longer axial length, lower RPE grayscale value, and lower ImageQ. These determinants should be considered when interpreting pRNFL grayscale value in glaucoma assessment. |
format | Online Article Text |
id | pubmed-8100177 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-81001772021-05-07 Determinants of peripapillary retinal nerve fiber layer’s grayscale value in normal eyes by spectral domain optical coherence tomography Xie, Xiaolin Chen, Binyao Yang, Jianling Huang, Chukai Qiu, Kunliang Zheng, Ce Zhang, Mingzhi Sci Rep Article To determine and evaluate the distribution, variation, and determinants of peripapillary retinal nerve fiber layer (pRNFL) grayscale value with spectral-domain optical coherence tomography (SD-OCT) in normal eyes. In this cross-sectional study, three hundred ninety-seven normal eyes from 397 healthy Chinese adults aged 18–80 were consecutively recruited from a tertiary eye care center. An SD-OCT instrument took pRNFL imaging. We used a customized software to measure pRNFL parameters, including thickness and grayscale value. Univariable and multiple linear regression analyses were performed to examine the relationship between pRNFL grayscale value with ocular (e.g., axial length [A.L.], spherical equivalent [S.E.], intraocular pressure [IOP]), and systemic (e.g., age, sex) factors. A total of 397 eyes from 397 healthy subjects were included in the final analysis with mean (± SD) age 44.63 ± 16.43 years (range 18–80 years) and 196 (49.4%) males. The mean average of pRNFL grayscale value and thickness 164.82 ± 5.69 and 106.68 ± 8.89 μm, respectively. pRNFL grayscale value in nasal sectors (163.26 ± 9.31) was significantly lower comparing those in all other five sectors (all with p < 0.001)]. In multivariable analysis, average pRNFL grayscale value was independently correlated to older age (β = − 0.053, p = 0.002), longer axial length (β = − 0.664, p = 0.003), lower RPE grayscale value (β = 0.372, p < 0.001) and lower ImageQ (β = 0.658, p < 0.001). In this study, we provided normative SD-OCT data on the pRNFL grayscale value profile in nonglaucomatous eyes. Lower average pRNFL grayscale value was independently correlated to older age, longer axial length, lower RPE grayscale value, and lower ImageQ. These determinants should be considered when interpreting pRNFL grayscale value in glaucoma assessment. Nature Publishing Group UK 2021-05-05 /pmc/articles/PMC8100177/ /pubmed/33953227 http://dx.doi.org/10.1038/s41598-021-88604-x Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Xie, Xiaolin Chen, Binyao Yang, Jianling Huang, Chukai Qiu, Kunliang Zheng, Ce Zhang, Mingzhi Determinants of peripapillary retinal nerve fiber layer’s grayscale value in normal eyes by spectral domain optical coherence tomography |
title | Determinants of peripapillary retinal nerve fiber layer’s grayscale value in normal eyes by spectral domain optical coherence tomography |
title_full | Determinants of peripapillary retinal nerve fiber layer’s grayscale value in normal eyes by spectral domain optical coherence tomography |
title_fullStr | Determinants of peripapillary retinal nerve fiber layer’s grayscale value in normal eyes by spectral domain optical coherence tomography |
title_full_unstemmed | Determinants of peripapillary retinal nerve fiber layer’s grayscale value in normal eyes by spectral domain optical coherence tomography |
title_short | Determinants of peripapillary retinal nerve fiber layer’s grayscale value in normal eyes by spectral domain optical coherence tomography |
title_sort | determinants of peripapillary retinal nerve fiber layer’s grayscale value in normal eyes by spectral domain optical coherence tomography |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8100177/ https://www.ncbi.nlm.nih.gov/pubmed/33953227 http://dx.doi.org/10.1038/s41598-021-88604-x |
work_keys_str_mv | AT xiexiaolin determinantsofperipapillaryretinalnervefiberlayersgrayscalevalueinnormaleyesbyspectraldomainopticalcoherencetomography AT chenbinyao determinantsofperipapillaryretinalnervefiberlayersgrayscalevalueinnormaleyesbyspectraldomainopticalcoherencetomography AT yangjianling determinantsofperipapillaryretinalnervefiberlayersgrayscalevalueinnormaleyesbyspectraldomainopticalcoherencetomography AT huangchukai determinantsofperipapillaryretinalnervefiberlayersgrayscalevalueinnormaleyesbyspectraldomainopticalcoherencetomography AT qiukunliang determinantsofperipapillaryretinalnervefiberlayersgrayscalevalueinnormaleyesbyspectraldomainopticalcoherencetomography AT zhengce determinantsofperipapillaryretinalnervefiberlayersgrayscalevalueinnormaleyesbyspectraldomainopticalcoherencetomography AT zhangmingzhi determinantsofperipapillaryretinalnervefiberlayersgrayscalevalueinnormaleyesbyspectraldomainopticalcoherencetomography |