Cargando…

Evaluation of Performance in Colon Capsule Endoscopy Reading by Endoscopy Nurses

BACKGROUND: Although there are papers reporting on the accuracy of colon capsule endoscopy (CCE) compared with colonoscopy (CS), there are few reports on the detection rates of significant lesions by endoscopy nurses. We previously reported no significant difference in the detection rates for small...

Descripción completa

Detalles Bibliográficos
Autores principales: Handa, Yukiko, Nakaji, Konosuke, Hyogo, Kayo, Kawakami, Makiko, Yamamoto, Tomomi, Fujiwara, Akiko, Kanda, Rika, Osawa, Motoyasu, Handa, Osamu, Matsumoto, Hiroshi, Umegaki, Eiji, Shiotani, Akiko
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8100384/
https://www.ncbi.nlm.nih.gov/pubmed/34007836
http://dx.doi.org/10.1155/2021/8826100
_version_ 1783688776687550464
author Handa, Yukiko
Nakaji, Konosuke
Hyogo, Kayo
Kawakami, Makiko
Yamamoto, Tomomi
Fujiwara, Akiko
Kanda, Rika
Osawa, Motoyasu
Handa, Osamu
Matsumoto, Hiroshi
Umegaki, Eiji
Shiotani, Akiko
author_facet Handa, Yukiko
Nakaji, Konosuke
Hyogo, Kayo
Kawakami, Makiko
Yamamoto, Tomomi
Fujiwara, Akiko
Kanda, Rika
Osawa, Motoyasu
Handa, Osamu
Matsumoto, Hiroshi
Umegaki, Eiji
Shiotani, Akiko
author_sort Handa, Yukiko
collection PubMed
description BACKGROUND: Although there are papers reporting on the accuracy of colon capsule endoscopy (CCE) compared with colonoscopy (CS), there are few reports on the detection rates of significant lesions by endoscopy nurses. We previously reported no significant difference in the detection rates for small bowel capsule endoscopy (SBCE) images among two well-trained physicians and one expert nurse. OBJECTIVE: To evaluate the reading time and detection rate of the significant lesions of CCE images among novice and trained expert endoscopy nurses and novice physicians. METHODS: CCE videos of 20 consecutive patients who performed both CCE and CS with clinically significant localized lesions were selected. Two trained expert endoscopy nurses, untrained two novice physicians, and novice three endoscopy nurses reviewed CCE videos. The detection rate of the lesions and reading time were compared among the three groups and were evaluated by comparison between the first and the second 10 videos. RESULTS: The median reading time was the shortest (19 min) in the trained expert endoscopy nurses and the longest (45 min) in the novice nurses. The number of thumbnails tended to be more in the trained expert endoscopy nurses in the first 10-video reading. Although the detection rates of small polyps (<5 mm) were significantly lower (46.5%, p=0.025) in the novice nurses compared to the others, they were improved (35.2% to 63.5%, p=0.015) in the second 10 videos. The detection rates of tumor lesions by either one of two trained expert endoscopy nurses were higher compared to those by each novice physician. CONCLUSIONS: The trained expert endoscopy nurses for CCE reading can reduce physician's time and improve the diagnostic yield.
format Online
Article
Text
id pubmed-8100384
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-81003842021-05-17 Evaluation of Performance in Colon Capsule Endoscopy Reading by Endoscopy Nurses Handa, Yukiko Nakaji, Konosuke Hyogo, Kayo Kawakami, Makiko Yamamoto, Tomomi Fujiwara, Akiko Kanda, Rika Osawa, Motoyasu Handa, Osamu Matsumoto, Hiroshi Umegaki, Eiji Shiotani, Akiko Can J Gastroenterol Hepatol Research Article BACKGROUND: Although there are papers reporting on the accuracy of colon capsule endoscopy (CCE) compared with colonoscopy (CS), there are few reports on the detection rates of significant lesions by endoscopy nurses. We previously reported no significant difference in the detection rates for small bowel capsule endoscopy (SBCE) images among two well-trained physicians and one expert nurse. OBJECTIVE: To evaluate the reading time and detection rate of the significant lesions of CCE images among novice and trained expert endoscopy nurses and novice physicians. METHODS: CCE videos of 20 consecutive patients who performed both CCE and CS with clinically significant localized lesions were selected. Two trained expert endoscopy nurses, untrained two novice physicians, and novice three endoscopy nurses reviewed CCE videos. The detection rate of the lesions and reading time were compared among the three groups and were evaluated by comparison between the first and the second 10 videos. RESULTS: The median reading time was the shortest (19 min) in the trained expert endoscopy nurses and the longest (45 min) in the novice nurses. The number of thumbnails tended to be more in the trained expert endoscopy nurses in the first 10-video reading. Although the detection rates of small polyps (<5 mm) were significantly lower (46.5%, p=0.025) in the novice nurses compared to the others, they were improved (35.2% to 63.5%, p=0.015) in the second 10 videos. The detection rates of tumor lesions by either one of two trained expert endoscopy nurses were higher compared to those by each novice physician. CONCLUSIONS: The trained expert endoscopy nurses for CCE reading can reduce physician's time and improve the diagnostic yield. Hindawi 2021-04-28 /pmc/articles/PMC8100384/ /pubmed/34007836 http://dx.doi.org/10.1155/2021/8826100 Text en Copyright © 2021 Yukiko Handa et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Handa, Yukiko
Nakaji, Konosuke
Hyogo, Kayo
Kawakami, Makiko
Yamamoto, Tomomi
Fujiwara, Akiko
Kanda, Rika
Osawa, Motoyasu
Handa, Osamu
Matsumoto, Hiroshi
Umegaki, Eiji
Shiotani, Akiko
Evaluation of Performance in Colon Capsule Endoscopy Reading by Endoscopy Nurses
title Evaluation of Performance in Colon Capsule Endoscopy Reading by Endoscopy Nurses
title_full Evaluation of Performance in Colon Capsule Endoscopy Reading by Endoscopy Nurses
title_fullStr Evaluation of Performance in Colon Capsule Endoscopy Reading by Endoscopy Nurses
title_full_unstemmed Evaluation of Performance in Colon Capsule Endoscopy Reading by Endoscopy Nurses
title_short Evaluation of Performance in Colon Capsule Endoscopy Reading by Endoscopy Nurses
title_sort evaluation of performance in colon capsule endoscopy reading by endoscopy nurses
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8100384/
https://www.ncbi.nlm.nih.gov/pubmed/34007836
http://dx.doi.org/10.1155/2021/8826100
work_keys_str_mv AT handayukiko evaluationofperformanceincoloncapsuleendoscopyreadingbyendoscopynurses
AT nakajikonosuke evaluationofperformanceincoloncapsuleendoscopyreadingbyendoscopynurses
AT hyogokayo evaluationofperformanceincoloncapsuleendoscopyreadingbyendoscopynurses
AT kawakamimakiko evaluationofperformanceincoloncapsuleendoscopyreadingbyendoscopynurses
AT yamamototomomi evaluationofperformanceincoloncapsuleendoscopyreadingbyendoscopynurses
AT fujiwaraakiko evaluationofperformanceincoloncapsuleendoscopyreadingbyendoscopynurses
AT kandarika evaluationofperformanceincoloncapsuleendoscopyreadingbyendoscopynurses
AT osawamotoyasu evaluationofperformanceincoloncapsuleendoscopyreadingbyendoscopynurses
AT handaosamu evaluationofperformanceincoloncapsuleendoscopyreadingbyendoscopynurses
AT matsumotohiroshi evaluationofperformanceincoloncapsuleendoscopyreadingbyendoscopynurses
AT umegakieiji evaluationofperformanceincoloncapsuleendoscopyreadingbyendoscopynurses
AT shiotaniakiko evaluationofperformanceincoloncapsuleendoscopyreadingbyendoscopynurses