Cargando…

Intravenous Delayed Gadolinium-Enhanced MR Imaging of the Endolymphatic Space: A Methodological Comparative Study

In-vivo non-invasive verification of endolymphatic hydrops (ELH) by means of intravenous delayed gadolinium (Gd) enhanced magnetic resonance imaging of the inner ear (iMRI) is rapidly developing into a standard clinical tool to investigate peripheral vestibulo-cochlear syndromes. In this context, me...

Descripción completa

Detalles Bibliográficos
Autores principales: Boegle, Rainer, Gerb, Johannes, Kierig, Emilie, Becker-Bense, Sandra, Ertl-Wagner, Birgit, Dieterich, Marianne, Kirsch, Valerie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8100585/
https://www.ncbi.nlm.nih.gov/pubmed/33967941
http://dx.doi.org/10.3389/fneur.2021.647296
_version_ 1783688818161876992
author Boegle, Rainer
Gerb, Johannes
Kierig, Emilie
Becker-Bense, Sandra
Ertl-Wagner, Birgit
Dieterich, Marianne
Kirsch, Valerie
author_facet Boegle, Rainer
Gerb, Johannes
Kierig, Emilie
Becker-Bense, Sandra
Ertl-Wagner, Birgit
Dieterich, Marianne
Kirsch, Valerie
author_sort Boegle, Rainer
collection PubMed
description In-vivo non-invasive verification of endolymphatic hydrops (ELH) by means of intravenous delayed gadolinium (Gd) enhanced magnetic resonance imaging of the inner ear (iMRI) is rapidly developing into a standard clinical tool to investigate peripheral vestibulo-cochlear syndromes. In this context, methodological comparative studies providing standardization and comparability between labs seem even more important, but so far very few are available. One hundred eight participants [75 patients with Meniere's disease (MD; 55.2 ± 14.9 years) and 33 vestibular healthy controls (HC; 46.4 ± 15.6 years)] were examined. The aim was to understand (i) how variations in acquisition protocols influence endolymphatic space (ELS) MR-signals; (ii) how ELS quantification methods correlate to each other or clinical data; and finally, (iii) how ELS extent influences MR-signals. Diagnostics included neuro-otological assessment, video-oculography during caloric stimulation, head-impulse test, audiometry, and iMRI. Data analysis provided semi-quantitative (SQ) visual grading and automatic algorithmic quantitative segmentation of ELS area [2D, mm(2)] and volume [3D, mm(3)] using deep learning-based segmentation and volumetric local thresholding. Within the range of 0.1–0.2 mmol/kg Gd dosage and a 4 h ± 30 min time delay, SQ grading and 2D- or 3D-quantifications were independent of signal intensity (SI) and signal-to-noise ratio (SNR; FWE corrected, p < 0.05). The ELS quantification methods used were highly reproducible across raters or thresholds and correlated strongly (0.3–0.8). However, 3D-quantifications showed the least variability. Asymmetry indices and normalized ELH proved the most useful for predicting quantitative clinical data. ELH size influenced SI (cochlear basal turn p < 0.001), but not SNR. SI could not predict the presence of ELH. In conclusion, (1) Gd dosage of 0.1–0.2 mmol/kg after 4 h ± 30 min time delay suffices for ELS quantification. (2) A consensus is needed on a clinical SQ grading classification including a standardized level of evaluation reconstructed to anatomical fixpoints. (3) 3D-quantification methods of the ELS are best suited for correlations with clinical variables and should include both ears and ELS values reported relative or normalized to size. (4) The presence of ELH increases signal intensity in the basal cochlear turn weakly, but cannot predict the presence of ELH.
format Online
Article
Text
id pubmed-8100585
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-81005852021-05-07 Intravenous Delayed Gadolinium-Enhanced MR Imaging of the Endolymphatic Space: A Methodological Comparative Study Boegle, Rainer Gerb, Johannes Kierig, Emilie Becker-Bense, Sandra Ertl-Wagner, Birgit Dieterich, Marianne Kirsch, Valerie Front Neurol Neurology In-vivo non-invasive verification of endolymphatic hydrops (ELH) by means of intravenous delayed gadolinium (Gd) enhanced magnetic resonance imaging of the inner ear (iMRI) is rapidly developing into a standard clinical tool to investigate peripheral vestibulo-cochlear syndromes. In this context, methodological comparative studies providing standardization and comparability between labs seem even more important, but so far very few are available. One hundred eight participants [75 patients with Meniere's disease (MD; 55.2 ± 14.9 years) and 33 vestibular healthy controls (HC; 46.4 ± 15.6 years)] were examined. The aim was to understand (i) how variations in acquisition protocols influence endolymphatic space (ELS) MR-signals; (ii) how ELS quantification methods correlate to each other or clinical data; and finally, (iii) how ELS extent influences MR-signals. Diagnostics included neuro-otological assessment, video-oculography during caloric stimulation, head-impulse test, audiometry, and iMRI. Data analysis provided semi-quantitative (SQ) visual grading and automatic algorithmic quantitative segmentation of ELS area [2D, mm(2)] and volume [3D, mm(3)] using deep learning-based segmentation and volumetric local thresholding. Within the range of 0.1–0.2 mmol/kg Gd dosage and a 4 h ± 30 min time delay, SQ grading and 2D- or 3D-quantifications were independent of signal intensity (SI) and signal-to-noise ratio (SNR; FWE corrected, p < 0.05). The ELS quantification methods used were highly reproducible across raters or thresholds and correlated strongly (0.3–0.8). However, 3D-quantifications showed the least variability. Asymmetry indices and normalized ELH proved the most useful for predicting quantitative clinical data. ELH size influenced SI (cochlear basal turn p < 0.001), but not SNR. SI could not predict the presence of ELH. In conclusion, (1) Gd dosage of 0.1–0.2 mmol/kg after 4 h ± 30 min time delay suffices for ELS quantification. (2) A consensus is needed on a clinical SQ grading classification including a standardized level of evaluation reconstructed to anatomical fixpoints. (3) 3D-quantification methods of the ELS are best suited for correlations with clinical variables and should include both ears and ELS values reported relative or normalized to size. (4) The presence of ELH increases signal intensity in the basal cochlear turn weakly, but cannot predict the presence of ELH. Frontiers Media S.A. 2021-04-22 /pmc/articles/PMC8100585/ /pubmed/33967941 http://dx.doi.org/10.3389/fneur.2021.647296 Text en Copyright © 2021 Boegle, Gerb, Kierig, Becker-Bense, Ertl-Wagner, Dieterich and Kirsch. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neurology
Boegle, Rainer
Gerb, Johannes
Kierig, Emilie
Becker-Bense, Sandra
Ertl-Wagner, Birgit
Dieterich, Marianne
Kirsch, Valerie
Intravenous Delayed Gadolinium-Enhanced MR Imaging of the Endolymphatic Space: A Methodological Comparative Study
title Intravenous Delayed Gadolinium-Enhanced MR Imaging of the Endolymphatic Space: A Methodological Comparative Study
title_full Intravenous Delayed Gadolinium-Enhanced MR Imaging of the Endolymphatic Space: A Methodological Comparative Study
title_fullStr Intravenous Delayed Gadolinium-Enhanced MR Imaging of the Endolymphatic Space: A Methodological Comparative Study
title_full_unstemmed Intravenous Delayed Gadolinium-Enhanced MR Imaging of the Endolymphatic Space: A Methodological Comparative Study
title_short Intravenous Delayed Gadolinium-Enhanced MR Imaging of the Endolymphatic Space: A Methodological Comparative Study
title_sort intravenous delayed gadolinium-enhanced mr imaging of the endolymphatic space: a methodological comparative study
topic Neurology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8100585/
https://www.ncbi.nlm.nih.gov/pubmed/33967941
http://dx.doi.org/10.3389/fneur.2021.647296
work_keys_str_mv AT boeglerainer intravenousdelayedgadoliniumenhancedmrimagingoftheendolymphaticspaceamethodologicalcomparativestudy
AT gerbjohannes intravenousdelayedgadoliniumenhancedmrimagingoftheendolymphaticspaceamethodologicalcomparativestudy
AT kierigemilie intravenousdelayedgadoliniumenhancedmrimagingoftheendolymphaticspaceamethodologicalcomparativestudy
AT beckerbensesandra intravenousdelayedgadoliniumenhancedmrimagingoftheendolymphaticspaceamethodologicalcomparativestudy
AT ertlwagnerbirgit intravenousdelayedgadoliniumenhancedmrimagingoftheendolymphaticspaceamethodologicalcomparativestudy
AT dieterichmarianne intravenousdelayedgadoliniumenhancedmrimagingoftheendolymphaticspaceamethodologicalcomparativestudy
AT kirschvalerie intravenousdelayedgadoliniumenhancedmrimagingoftheendolymphaticspaceamethodologicalcomparativestudy