Cargando…

Short‐term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer Lens implantation

BACKGROUND: To describe the very early vault changes in the first month after Implantable Collamer Lens (ICL) implantation and to evaluate the effect of preoperative biometric factors on vault. METHODS: Eighty-three eyes from eighty-three subjects with complete data who met follow-up requirements we...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhu, Qiu-Jian, Chen, Wen-Jing, Zhu, Wei-Jian, Xiao, Hai-Xiang, Zhu, Man-Hui, Ma, Lie, Yuan, You, Song, E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8101126/
https://www.ncbi.nlm.nih.gov/pubmed/33957891
http://dx.doi.org/10.1186/s12886-021-01963-x
_version_ 1783688908676005888
author Zhu, Qiu-Jian
Chen, Wen-Jing
Zhu, Wei-Jian
Xiao, Hai-Xiang
Zhu, Man-Hui
Ma, Lie
Yuan, You
Song, E.
author_facet Zhu, Qiu-Jian
Chen, Wen-Jing
Zhu, Wei-Jian
Xiao, Hai-Xiang
Zhu, Man-Hui
Ma, Lie
Yuan, You
Song, E.
author_sort Zhu, Qiu-Jian
collection PubMed
description BACKGROUND: To describe the very early vault changes in the first month after Implantable Collamer Lens (ICL) implantation and to evaluate the effect of preoperative biometric factors on vault. METHODS: Eighty-three eyes from eighty-three subjects with complete data who met follow-up requirements were recruited in this retrospective study between May 2019 and March 2020. We quantitatively assessed the postoperative vault at 2 h, 1 day, 1 week, and 1 month following implantation. Associations between the postoperative vault and age, ICL size, spherical equivalent (SE), axial length (AL), central corneal thickness (CCT), flat keratometry (K), steep K, mean K, anterior chamber depth (ACD), crystalline lens thickness (LT), white-to-white (WTW) diameter obtained by three devices, horizontal and vertical sulcus-to-sulcus (STS) diameter, bright and dark pupil sizes (BPS and DPS) and DPS-BPS were investigated using Spearman’s correlation analysis and stepwise multiple regression analysis. RESULTS: The mean vault values at 2 h, 1 day, 1 week, and 1 month after ICL implantation were 672.05 ± 30.72, 389.15 ± 28.33, 517.23 ± 30.76 and 530.12 ± 30.22 μm, respectively. Significant differences were found in the vault values at 2 h, 1 day and 1 week after the operation. The ICL size (β = 0.942; p < 0.001), followed by horizontal STS (β = -0.517; p < 0.001), crystalline LT (β = -0.376; p < 0.001) and vertical STS (β = -0.257; p = 0.017), significantly influenced the vault at 1 month after the operation. The multiple regression equation was expressed as follows: central vault (µm) = -1369.05 + 657.121 × ICL size- 287.408 × horizontal STS − 432.497 × crystalline LT − 137.33 × vertical STS (adjusted R(2) = 0.643). CONCLUSIONS: After ICL implantation, the vault decreased and then increased, but it did not return to the vault value 2 h after surgery. The ICL size, horizontal and vertical STS and crystalline LT are key factors for predicting postoperative vaulting. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12886-021-01963-x.
format Online
Article
Text
id pubmed-8101126
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-81011262021-05-06 Short‐term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer Lens implantation Zhu, Qiu-Jian Chen, Wen-Jing Zhu, Wei-Jian Xiao, Hai-Xiang Zhu, Man-Hui Ma, Lie Yuan, You Song, E. BMC Ophthalmol Research Article BACKGROUND: To describe the very early vault changes in the first month after Implantable Collamer Lens (ICL) implantation and to evaluate the effect of preoperative biometric factors on vault. METHODS: Eighty-three eyes from eighty-three subjects with complete data who met follow-up requirements were recruited in this retrospective study between May 2019 and March 2020. We quantitatively assessed the postoperative vault at 2 h, 1 day, 1 week, and 1 month following implantation. Associations between the postoperative vault and age, ICL size, spherical equivalent (SE), axial length (AL), central corneal thickness (CCT), flat keratometry (K), steep K, mean K, anterior chamber depth (ACD), crystalline lens thickness (LT), white-to-white (WTW) diameter obtained by three devices, horizontal and vertical sulcus-to-sulcus (STS) diameter, bright and dark pupil sizes (BPS and DPS) and DPS-BPS were investigated using Spearman’s correlation analysis and stepwise multiple regression analysis. RESULTS: The mean vault values at 2 h, 1 day, 1 week, and 1 month after ICL implantation were 672.05 ± 30.72, 389.15 ± 28.33, 517.23 ± 30.76 and 530.12 ± 30.22 μm, respectively. Significant differences were found in the vault values at 2 h, 1 day and 1 week after the operation. The ICL size (β = 0.942; p < 0.001), followed by horizontal STS (β = -0.517; p < 0.001), crystalline LT (β = -0.376; p < 0.001) and vertical STS (β = -0.257; p = 0.017), significantly influenced the vault at 1 month after the operation. The multiple regression equation was expressed as follows: central vault (µm) = -1369.05 + 657.121 × ICL size- 287.408 × horizontal STS − 432.497 × crystalline LT − 137.33 × vertical STS (adjusted R(2) = 0.643). CONCLUSIONS: After ICL implantation, the vault decreased and then increased, but it did not return to the vault value 2 h after surgery. The ICL size, horizontal and vertical STS and crystalline LT are key factors for predicting postoperative vaulting. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12886-021-01963-x. BioMed Central 2021-05-06 /pmc/articles/PMC8101126/ /pubmed/33957891 http://dx.doi.org/10.1186/s12886-021-01963-x Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Zhu, Qiu-Jian
Chen, Wen-Jing
Zhu, Wei-Jian
Xiao, Hai-Xiang
Zhu, Man-Hui
Ma, Lie
Yuan, You
Song, E.
Short‐term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer Lens implantation
title Short‐term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer Lens implantation
title_full Short‐term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer Lens implantation
title_fullStr Short‐term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer Lens implantation
title_full_unstemmed Short‐term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer Lens implantation
title_short Short‐term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer Lens implantation
title_sort short‐term changes in and preoperative factors affecting vaulting after posterior chamber phakic implantable collamer lens implantation
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8101126/
https://www.ncbi.nlm.nih.gov/pubmed/33957891
http://dx.doi.org/10.1186/s12886-021-01963-x
work_keys_str_mv AT zhuqiujian shorttermchangesinandpreoperativefactorsaffectingvaultingafterposteriorchamberphakicimplantablecollamerlensimplantation
AT chenwenjing shorttermchangesinandpreoperativefactorsaffectingvaultingafterposteriorchamberphakicimplantablecollamerlensimplantation
AT zhuweijian shorttermchangesinandpreoperativefactorsaffectingvaultingafterposteriorchamberphakicimplantablecollamerlensimplantation
AT xiaohaixiang shorttermchangesinandpreoperativefactorsaffectingvaultingafterposteriorchamberphakicimplantablecollamerlensimplantation
AT zhumanhui shorttermchangesinandpreoperativefactorsaffectingvaultingafterposteriorchamberphakicimplantablecollamerlensimplantation
AT malie shorttermchangesinandpreoperativefactorsaffectingvaultingafterposteriorchamberphakicimplantablecollamerlensimplantation
AT yuanyou shorttermchangesinandpreoperativefactorsaffectingvaultingafterposteriorchamberphakicimplantablecollamerlensimplantation
AT songe shorttermchangesinandpreoperativefactorsaffectingvaultingafterposteriorchamberphakicimplantablecollamerlensimplantation