Cargando…
Comparison of Ultrasonic Dissection and Suture Ligation for Mesoappendix in Laparoscopic Appendectomy
Objective To compare the use of ultrasonic dissector and suture ligation for mesoappendix in laparoscopic appendectomy in terms of mean operative time and per-operative bleed. Methodology This was a randomized controlled trial conducted at Surgical Unit II, Holy Family Hospital over a period of six...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8101508/ https://www.ncbi.nlm.nih.gov/pubmed/33968526 http://dx.doi.org/10.7759/cureus.14316 |
_version_ | 1783688965490999296 |
---|---|
author | Qaiser, Muhammad Umar Nazir, Aamna Khan, Muhammad Sheharyar Butt, Hafiza Kiran Anwar, Muhammad |
author_facet | Qaiser, Muhammad Umar Nazir, Aamna Khan, Muhammad Sheharyar Butt, Hafiza Kiran Anwar, Muhammad |
author_sort | Qaiser, Muhammad Umar |
collection | PubMed |
description | Objective To compare the use of ultrasonic dissector and suture ligation for mesoappendix in laparoscopic appendectomy in terms of mean operative time and per-operative bleed. Methodology This was a randomized controlled trial conducted at Surgical Unit II, Holy Family Hospital over a period of six months. All patients with the diagnosis of acute appendicitis who presented in the emergency department of Holy Family Hospital on the call days of Surgical Unit II undergoing laparoscopic appendectomy were included in the study. After taking informed consent about the respective procedure, patients were allocated to two groups using computer-generated random numbers. Group A was operated using harmonic scalpel and in Group B suture ligation was done. Total time required to ligate the mesoappendix or to cauterize it using the harmonic scalpel was measured in minutes. Data was entered and analyzed in SPSS version 21.0 (IBM Corp., Armonk, NY). Results A total of 110 patients were enrolled in the study according to the inclusion criteria of the study. Patients were randomly divided into two equal groups. Patients in Group A were operated using harmonic scalpel whereas patients in Group B were operated by suture ligation for dealing the mesoappendix in laparoscopic appendectomy. Mean operative time to ligate the mesoappendix for Group A patients was 1.56 (SD = 0.68) minutes while that of Group B was 21.07 (SD = 2.84) minutes. There was no per-operative bleeding in case of Group A while its incidence was 24% of patients in Group B. Results were statistically significant. Conclusion The conclusion of the study is that the use of harmonic scalpel was better than suture ligation for ligating the mesoappendix in laparoscopic appendectomy in terms of mean operative time and per operative bleed, hence it's preferable over the later in laparoscopic appendectomy. |
format | Online Article Text |
id | pubmed-8101508 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-81015082021-05-07 Comparison of Ultrasonic Dissection and Suture Ligation for Mesoappendix in Laparoscopic Appendectomy Qaiser, Muhammad Umar Nazir, Aamna Khan, Muhammad Sheharyar Butt, Hafiza Kiran Anwar, Muhammad Cureus General Surgery Objective To compare the use of ultrasonic dissector and suture ligation for mesoappendix in laparoscopic appendectomy in terms of mean operative time and per-operative bleed. Methodology This was a randomized controlled trial conducted at Surgical Unit II, Holy Family Hospital over a period of six months. All patients with the diagnosis of acute appendicitis who presented in the emergency department of Holy Family Hospital on the call days of Surgical Unit II undergoing laparoscopic appendectomy were included in the study. After taking informed consent about the respective procedure, patients were allocated to two groups using computer-generated random numbers. Group A was operated using harmonic scalpel and in Group B suture ligation was done. Total time required to ligate the mesoappendix or to cauterize it using the harmonic scalpel was measured in minutes. Data was entered and analyzed in SPSS version 21.0 (IBM Corp., Armonk, NY). Results A total of 110 patients were enrolled in the study according to the inclusion criteria of the study. Patients were randomly divided into two equal groups. Patients in Group A were operated using harmonic scalpel whereas patients in Group B were operated by suture ligation for dealing the mesoappendix in laparoscopic appendectomy. Mean operative time to ligate the mesoappendix for Group A patients was 1.56 (SD = 0.68) minutes while that of Group B was 21.07 (SD = 2.84) minutes. There was no per-operative bleeding in case of Group A while its incidence was 24% of patients in Group B. Results were statistically significant. Conclusion The conclusion of the study is that the use of harmonic scalpel was better than suture ligation for ligating the mesoappendix in laparoscopic appendectomy in terms of mean operative time and per operative bleed, hence it's preferable over the later in laparoscopic appendectomy. Cureus 2021-04-06 /pmc/articles/PMC8101508/ /pubmed/33968526 http://dx.doi.org/10.7759/cureus.14316 Text en Copyright © 2021, Qaiser et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | General Surgery Qaiser, Muhammad Umar Nazir, Aamna Khan, Muhammad Sheharyar Butt, Hafiza Kiran Anwar, Muhammad Comparison of Ultrasonic Dissection and Suture Ligation for Mesoappendix in Laparoscopic Appendectomy |
title | Comparison of Ultrasonic Dissection and Suture Ligation for Mesoappendix in Laparoscopic Appendectomy |
title_full | Comparison of Ultrasonic Dissection and Suture Ligation for Mesoappendix in Laparoscopic Appendectomy |
title_fullStr | Comparison of Ultrasonic Dissection and Suture Ligation for Mesoappendix in Laparoscopic Appendectomy |
title_full_unstemmed | Comparison of Ultrasonic Dissection and Suture Ligation for Mesoappendix in Laparoscopic Appendectomy |
title_short | Comparison of Ultrasonic Dissection and Suture Ligation for Mesoappendix in Laparoscopic Appendectomy |
title_sort | comparison of ultrasonic dissection and suture ligation for mesoappendix in laparoscopic appendectomy |
topic | General Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8101508/ https://www.ncbi.nlm.nih.gov/pubmed/33968526 http://dx.doi.org/10.7759/cureus.14316 |
work_keys_str_mv | AT qaisermuhammadumar comparisonofultrasonicdissectionandsutureligationformesoappendixinlaparoscopicappendectomy AT naziraamna comparisonofultrasonicdissectionandsutureligationformesoappendixinlaparoscopicappendectomy AT khanmuhammadsheharyar comparisonofultrasonicdissectionandsutureligationformesoappendixinlaparoscopicappendectomy AT butthafizakiran comparisonofultrasonicdissectionandsutureligationformesoappendixinlaparoscopicappendectomy AT anwarmuhammad comparisonofultrasonicdissectionandsutureligationformesoappendixinlaparoscopicappendectomy |