Cargando…

Paired personal interaction reveals objective differences between pushing and holding isometric muscle action

In sports and movement sciences isometric muscle function is usually measured by pushing against a stable resistance. However, subjectively one can hold or push isometrically. Several investigations suggest a distinction of those forms. The aim of this study was to investigate whether these two form...

Descripción completa

Detalles Bibliográficos
Autores principales: Schaefer, Laura V., Bittmann, Frank N.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8101915/
https://www.ncbi.nlm.nih.gov/pubmed/33956801
http://dx.doi.org/10.1371/journal.pone.0238331
_version_ 1783689024030900224
author Schaefer, Laura V.
Bittmann, Frank N.
author_facet Schaefer, Laura V.
Bittmann, Frank N.
author_sort Schaefer, Laura V.
collection PubMed
description In sports and movement sciences isometric muscle function is usually measured by pushing against a stable resistance. However, subjectively one can hold or push isometrically. Several investigations suggest a distinction of those forms. The aim of this study was to investigate whether these two forms of isometric muscle action can be distinguished by objective parameters in an interpersonal setting. 20 subjects were grouped in 10 same sex pairs, in which one partner should perform the pushing isometric muscle action (PIMA) and the other partner executed the holding isometric muscle action (HIMA). The partners had contact at the distal forearms via an interface, which included a strain gauge and an acceleration sensor. The mechanical oscillations of the triceps brachii (MMGtri) muscle, its tendon (MTGtri) and the abdominal muscle (MMGobl) were recorded by a piezoelectric-sensor-based measurement system. Each partner performed three 15s (80% MVIC) and two fatiguing trials (90% MVIC) during PIMA and HIMA, respectively. Parameters to compare PIMA and HIMA were the mean frequency, the normalized mean amplitude, the amplitude variation, the power in the frequency range of 8 to 15 Hz, a special power-frequency ratio and the number of task failures during HIMA or PIMA (partner who quit the task). A “HIMA failure” occurred in 85% of trials (p < 0.001). No significant differences between PIMA and HIMA were found for the mean frequency and normalized amplitude. The MMGobl showed significantly higher values of amplitude variation (15s: p = 0.013; fatiguing: p = 0.007) and of power-frequency-ratio (15s: p = 0.040; fatiguing: p = 0.002) during HIMA and a higher power in the range of 8 to 15 Hz during PIMA (15s: p = 0.001; fatiguing: p = 0.011). MMGtri and MTGtri showed no significant differences. Based on the findings it is suggested that a holding and a pushing isometric muscle action can be distinguished objectively, whereby a more complex neural control is assumed for HIMA.
format Online
Article
Text
id pubmed-8101915
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-81019152021-05-17 Paired personal interaction reveals objective differences between pushing and holding isometric muscle action Schaefer, Laura V. Bittmann, Frank N. PLoS One Research Article In sports and movement sciences isometric muscle function is usually measured by pushing against a stable resistance. However, subjectively one can hold or push isometrically. Several investigations suggest a distinction of those forms. The aim of this study was to investigate whether these two forms of isometric muscle action can be distinguished by objective parameters in an interpersonal setting. 20 subjects were grouped in 10 same sex pairs, in which one partner should perform the pushing isometric muscle action (PIMA) and the other partner executed the holding isometric muscle action (HIMA). The partners had contact at the distal forearms via an interface, which included a strain gauge and an acceleration sensor. The mechanical oscillations of the triceps brachii (MMGtri) muscle, its tendon (MTGtri) and the abdominal muscle (MMGobl) were recorded by a piezoelectric-sensor-based measurement system. Each partner performed three 15s (80% MVIC) and two fatiguing trials (90% MVIC) during PIMA and HIMA, respectively. Parameters to compare PIMA and HIMA were the mean frequency, the normalized mean amplitude, the amplitude variation, the power in the frequency range of 8 to 15 Hz, a special power-frequency ratio and the number of task failures during HIMA or PIMA (partner who quit the task). A “HIMA failure” occurred in 85% of trials (p < 0.001). No significant differences between PIMA and HIMA were found for the mean frequency and normalized amplitude. The MMGobl showed significantly higher values of amplitude variation (15s: p = 0.013; fatiguing: p = 0.007) and of power-frequency-ratio (15s: p = 0.040; fatiguing: p = 0.002) during HIMA and a higher power in the range of 8 to 15 Hz during PIMA (15s: p = 0.001; fatiguing: p = 0.011). MMGtri and MTGtri showed no significant differences. Based on the findings it is suggested that a holding and a pushing isometric muscle action can be distinguished objectively, whereby a more complex neural control is assumed for HIMA. Public Library of Science 2021-05-06 /pmc/articles/PMC8101915/ /pubmed/33956801 http://dx.doi.org/10.1371/journal.pone.0238331 Text en © 2021 Schaefer, Bittmann https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Schaefer, Laura V.
Bittmann, Frank N.
Paired personal interaction reveals objective differences between pushing and holding isometric muscle action
title Paired personal interaction reveals objective differences between pushing and holding isometric muscle action
title_full Paired personal interaction reveals objective differences between pushing and holding isometric muscle action
title_fullStr Paired personal interaction reveals objective differences between pushing and holding isometric muscle action
title_full_unstemmed Paired personal interaction reveals objective differences between pushing and holding isometric muscle action
title_short Paired personal interaction reveals objective differences between pushing and holding isometric muscle action
title_sort paired personal interaction reveals objective differences between pushing and holding isometric muscle action
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8101915/
https://www.ncbi.nlm.nih.gov/pubmed/33956801
http://dx.doi.org/10.1371/journal.pone.0238331
work_keys_str_mv AT schaeferlaurav pairedpersonalinteractionrevealsobjectivedifferencesbetweenpushingandholdingisometricmuscleaction
AT bittmannfrankn pairedpersonalinteractionrevealsobjectivedifferencesbetweenpushingandholdingisometricmuscleaction