Cargando…
Changes in the Optical Corneal Densitometry, Visual Acuity, and Refractive Error after the Annular Intracorneal Inlay Implantation
PURPOSE: To investigate the changes in the optical corneal densitometry as an objective method in assessing the corneal light back-scattering before and 1 year after the annular intracorneal inlay (AICI) implantation into the keratoconic corneas. METHODS: Changes in the optical corneal densitometry,...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8102947/ https://www.ncbi.nlm.nih.gov/pubmed/34084953 http://dx.doi.org/10.4103/JOCO.JOCO_154_20 |
_version_ | 1783689212271263744 |
---|---|
author | Jabbarvand, Mahmoud Khodaparast, Mehdi Jamali, Alireza Ahmadzadeh, Hooman Bordbar, Soodeh |
author_facet | Jabbarvand, Mahmoud Khodaparast, Mehdi Jamali, Alireza Ahmadzadeh, Hooman Bordbar, Soodeh |
author_sort | Jabbarvand, Mahmoud |
collection | PubMed |
description | PURPOSE: To investigate the changes in the optical corneal densitometry as an objective method in assessing the corneal light back-scattering before and 1 year after the annular intracorneal inlay (AICI) implantation into the keratoconic corneas. METHODS: Changes in the optical corneal densitometry, visual acuity, refractive, and tomographical status were assessed before and 1 year after the AICI implantation into the corneas with different stages of keratoconus. Optical corneal densitometry was evaluated using the Pentacam-HR in 0–2, 2–6, 6–10, and 10–12 mm rings in the anterior 120 μ, central layers, posterior 60 μ and also the total value were measured for cornea in the Grey Scale Unit criterion. RESULTS: Totally, 34 patients with keratoconus were studied; the uncorrected and best corrected visual acuity were increased after the surgery (0.98 ± 0.25 to 0.53 ± 0.30 logMAR, P < 0.001 and 0.26 ± 0.18 to 0.19 ± 0.14, P = 0.007 logMAR, respectively); the spherical equivalent was decreased from −4.45 ± 2.25 to − 2.06 ± 2.01 D (P = 0.004). AICI implantation led to an increase in the amount of optical corneal densitometry in 0–2 mm central, 2–6 mm central, 6–10 mm central, total central, 2–6 mm posterior, and 2–6 mm total rings (all, P < 0.05); however, a decrease was observed in 0–2 mm anterior ring (P = 0.049). Results of statistical analysis showed that the total optical corneal densitometry, anterior total, and posterior total back-scattering did not change after the AICI implantation (all, P > 0.05). CONCLUSIONS: Our results revealed a significant improvement in the visual function, including refractive error and visual acuity following the AICI implantation. Changes in the optical corneal densitometry were different in distinct regions and layers however, the total amount did not change after the AICI implantation. |
format | Online Article Text |
id | pubmed-8102947 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-81029472021-06-02 Changes in the Optical Corneal Densitometry, Visual Acuity, and Refractive Error after the Annular Intracorneal Inlay Implantation Jabbarvand, Mahmoud Khodaparast, Mehdi Jamali, Alireza Ahmadzadeh, Hooman Bordbar, Soodeh J Curr Ophthalmol Original Article PURPOSE: To investigate the changes in the optical corneal densitometry as an objective method in assessing the corneal light back-scattering before and 1 year after the annular intracorneal inlay (AICI) implantation into the keratoconic corneas. METHODS: Changes in the optical corneal densitometry, visual acuity, refractive, and tomographical status were assessed before and 1 year after the AICI implantation into the corneas with different stages of keratoconus. Optical corneal densitometry was evaluated using the Pentacam-HR in 0–2, 2–6, 6–10, and 10–12 mm rings in the anterior 120 μ, central layers, posterior 60 μ and also the total value were measured for cornea in the Grey Scale Unit criterion. RESULTS: Totally, 34 patients with keratoconus were studied; the uncorrected and best corrected visual acuity were increased after the surgery (0.98 ± 0.25 to 0.53 ± 0.30 logMAR, P < 0.001 and 0.26 ± 0.18 to 0.19 ± 0.14, P = 0.007 logMAR, respectively); the spherical equivalent was decreased from −4.45 ± 2.25 to − 2.06 ± 2.01 D (P = 0.004). AICI implantation led to an increase in the amount of optical corneal densitometry in 0–2 mm central, 2–6 mm central, 6–10 mm central, total central, 2–6 mm posterior, and 2–6 mm total rings (all, P < 0.05); however, a decrease was observed in 0–2 mm anterior ring (P = 0.049). Results of statistical analysis showed that the total optical corneal densitometry, anterior total, and posterior total back-scattering did not change after the AICI implantation (all, P > 0.05). CONCLUSIONS: Our results revealed a significant improvement in the visual function, including refractive error and visual acuity following the AICI implantation. Changes in the optical corneal densitometry were different in distinct regions and layers however, the total amount did not change after the AICI implantation. Wolters Kluwer - Medknow 2021-03-26 /pmc/articles/PMC8102947/ /pubmed/34084953 http://dx.doi.org/10.4103/JOCO.JOCO_154_20 Text en Copyright: © 2021 Journal of Current Ophthalmology https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Jabbarvand, Mahmoud Khodaparast, Mehdi Jamali, Alireza Ahmadzadeh, Hooman Bordbar, Soodeh Changes in the Optical Corneal Densitometry, Visual Acuity, and Refractive Error after the Annular Intracorneal Inlay Implantation |
title | Changes in the Optical Corneal Densitometry, Visual Acuity, and Refractive Error after the Annular Intracorneal Inlay Implantation |
title_full | Changes in the Optical Corneal Densitometry, Visual Acuity, and Refractive Error after the Annular Intracorneal Inlay Implantation |
title_fullStr | Changes in the Optical Corneal Densitometry, Visual Acuity, and Refractive Error after the Annular Intracorneal Inlay Implantation |
title_full_unstemmed | Changes in the Optical Corneal Densitometry, Visual Acuity, and Refractive Error after the Annular Intracorneal Inlay Implantation |
title_short | Changes in the Optical Corneal Densitometry, Visual Acuity, and Refractive Error after the Annular Intracorneal Inlay Implantation |
title_sort | changes in the optical corneal densitometry, visual acuity, and refractive error after the annular intracorneal inlay implantation |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8102947/ https://www.ncbi.nlm.nih.gov/pubmed/34084953 http://dx.doi.org/10.4103/JOCO.JOCO_154_20 |
work_keys_str_mv | AT jabbarvandmahmoud changesintheopticalcornealdensitometryvisualacuityandrefractiveerroraftertheannularintracornealinlayimplantation AT khodaparastmehdi changesintheopticalcornealdensitometryvisualacuityandrefractiveerroraftertheannularintracornealinlayimplantation AT jamalialireza changesintheopticalcornealdensitometryvisualacuityandrefractiveerroraftertheannularintracornealinlayimplantation AT ahmadzadehhooman changesintheopticalcornealdensitometryvisualacuityandrefractiveerroraftertheannularintracornealinlayimplantation AT bordbarsoodeh changesintheopticalcornealdensitometryvisualacuityandrefractiveerroraftertheannularintracornealinlayimplantation |