Cargando…

Assessment of Protocol Impact on Subjectivity Uncertainty When Analyzing Peripheral Blood Mononuclear Cell Flow Cytometry Data Files

Measured variability of product within Cell and Gene Therapy (CGT) manufacturing arises from numerous sources across pre-analytical to post-analytical phases of testing. Operators are a function of the manufacturing process and are an important source of variability as a result of personal differenc...

Descripción completa

Detalles Bibliográficos
Autores principales: Grant, Rebecca, Coopman, Karen, Silva-Gomes, Sandro, Campbell, Jonathan J., Kara, Bo, Braybrook, Julian, Petzing, Jon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8103269/
https://www.ncbi.nlm.nih.gov/pubmed/33808088
http://dx.doi.org/10.3390/mps4020024
_version_ 1783689285803704320
author Grant, Rebecca
Coopman, Karen
Silva-Gomes, Sandro
Campbell, Jonathan J.
Kara, Bo
Braybrook, Julian
Petzing, Jon
author_facet Grant, Rebecca
Coopman, Karen
Silva-Gomes, Sandro
Campbell, Jonathan J.
Kara, Bo
Braybrook, Julian
Petzing, Jon
author_sort Grant, Rebecca
collection PubMed
description Measured variability of product within Cell and Gene Therapy (CGT) manufacturing arises from numerous sources across pre-analytical to post-analytical phases of testing. Operators are a function of the manufacturing process and are an important source of variability as a result of personal differences impacted by numerous factors. This research uses measurement uncertainty in comparison to Coefficient of Variation to quantify variation of participants when they complete Flow Cytometry data analysis through a 5-step gating sequence. Two study stages captured participants applying gates using their own judgement, and then following a diagrammatical protocol, respectively. Measurement uncertainty was quantified for each participant (and analysis phase) by following Guide to the Expression of Uncertainty in Measurement protocols, combining their standard deviations in quadrature from each gating step in the respective protocols. When participants followed a diagrammatical protocol, variation between participants reduced by 57%, increasing confidence in a more uniform reported cell count percentage. Measurement uncertainty provided greater resolution to the analysis processes, identifying that most variability contributed in the Flow Cytometry gating process is from the very first gate, where isolating target cells from dead or dying cells is required. This work has demonstrated the potential for greater usage of measurement uncertainty within CGT manufacturing scenarios, due to the resolution it provides for root cause analysis and continuous improvement.
format Online
Article
Text
id pubmed-8103269
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-81032692021-05-08 Assessment of Protocol Impact on Subjectivity Uncertainty When Analyzing Peripheral Blood Mononuclear Cell Flow Cytometry Data Files Grant, Rebecca Coopman, Karen Silva-Gomes, Sandro Campbell, Jonathan J. Kara, Bo Braybrook, Julian Petzing, Jon Methods Protoc Article Measured variability of product within Cell and Gene Therapy (CGT) manufacturing arises from numerous sources across pre-analytical to post-analytical phases of testing. Operators are a function of the manufacturing process and are an important source of variability as a result of personal differences impacted by numerous factors. This research uses measurement uncertainty in comparison to Coefficient of Variation to quantify variation of participants when they complete Flow Cytometry data analysis through a 5-step gating sequence. Two study stages captured participants applying gates using their own judgement, and then following a diagrammatical protocol, respectively. Measurement uncertainty was quantified for each participant (and analysis phase) by following Guide to the Expression of Uncertainty in Measurement protocols, combining their standard deviations in quadrature from each gating step in the respective protocols. When participants followed a diagrammatical protocol, variation between participants reduced by 57%, increasing confidence in a more uniform reported cell count percentage. Measurement uncertainty provided greater resolution to the analysis processes, identifying that most variability contributed in the Flow Cytometry gating process is from the very first gate, where isolating target cells from dead or dying cells is required. This work has demonstrated the potential for greater usage of measurement uncertainty within CGT manufacturing scenarios, due to the resolution it provides for root cause analysis and continuous improvement. MDPI 2021-03-30 /pmc/articles/PMC8103269/ /pubmed/33808088 http://dx.doi.org/10.3390/mps4020024 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ).
spellingShingle Article
Grant, Rebecca
Coopman, Karen
Silva-Gomes, Sandro
Campbell, Jonathan J.
Kara, Bo
Braybrook, Julian
Petzing, Jon
Assessment of Protocol Impact on Subjectivity Uncertainty When Analyzing Peripheral Blood Mononuclear Cell Flow Cytometry Data Files
title Assessment of Protocol Impact on Subjectivity Uncertainty When Analyzing Peripheral Blood Mononuclear Cell Flow Cytometry Data Files
title_full Assessment of Protocol Impact on Subjectivity Uncertainty When Analyzing Peripheral Blood Mononuclear Cell Flow Cytometry Data Files
title_fullStr Assessment of Protocol Impact on Subjectivity Uncertainty When Analyzing Peripheral Blood Mononuclear Cell Flow Cytometry Data Files
title_full_unstemmed Assessment of Protocol Impact on Subjectivity Uncertainty When Analyzing Peripheral Blood Mononuclear Cell Flow Cytometry Data Files
title_short Assessment of Protocol Impact on Subjectivity Uncertainty When Analyzing Peripheral Blood Mononuclear Cell Flow Cytometry Data Files
title_sort assessment of protocol impact on subjectivity uncertainty when analyzing peripheral blood mononuclear cell flow cytometry data files
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8103269/
https://www.ncbi.nlm.nih.gov/pubmed/33808088
http://dx.doi.org/10.3390/mps4020024
work_keys_str_mv AT grantrebecca assessmentofprotocolimpactonsubjectivityuncertaintywhenanalyzingperipheralbloodmononuclearcellflowcytometrydatafiles
AT coopmankaren assessmentofprotocolimpactonsubjectivityuncertaintywhenanalyzingperipheralbloodmononuclearcellflowcytometrydatafiles
AT silvagomessandro assessmentofprotocolimpactonsubjectivityuncertaintywhenanalyzingperipheralbloodmononuclearcellflowcytometrydatafiles
AT campbelljonathanj assessmentofprotocolimpactonsubjectivityuncertaintywhenanalyzingperipheralbloodmononuclearcellflowcytometrydatafiles
AT karabo assessmentofprotocolimpactonsubjectivityuncertaintywhenanalyzingperipheralbloodmononuclearcellflowcytometrydatafiles
AT braybrookjulian assessmentofprotocolimpactonsubjectivityuncertaintywhenanalyzingperipheralbloodmononuclearcellflowcytometrydatafiles
AT petzingjon assessmentofprotocolimpactonsubjectivityuncertaintywhenanalyzingperipheralbloodmononuclearcellflowcytometrydatafiles