Cargando…

Analysis of the factors influencing retrograde removal of double J ureteral stents using a simple snare technique in female patients

BACKGROUND: To identify the factors related to the effectiveness of retrograde removal of double J ureteral stents using a simple snare technique in female patients. METHODS: It was a retrospective observational study. From 2012 to 2017, 128 female patients underwent fluoroscopy-guided, retrograde d...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Cheng-Shi, Shin, Ji Hoon, Li, Hai-Liang, Guo, Chen-Yang, Kim, Jong Woo, Zheng, Lin, Yao, Quan-Jun, Geng, Xiang, Wang, Tan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8106078/
https://www.ncbi.nlm.nih.gov/pubmed/33987372
http://dx.doi.org/10.21037/atm-21-1113
Descripción
Sumario:BACKGROUND: To identify the factors related to the effectiveness of retrograde removal of double J ureteral stents using a simple snare technique in female patients. METHODS: It was a retrospective observational study. From 2012 to 2017, 128 female patients underwent fluoroscopy-guided, retrograde double J stent removal with or without replacement using a simple snare technique. The position of the tip of the double J stent in the urinary bladder was classified according to position types A, B, C, and D, corresponding to the ipsilateral lateral, ipsilateral medial, contralateral medial, and contralateral lateral quadrants of the urinary bladder, respectively. The factors influencing the fluoroscopy time upon removal of the double J stent were analyzed. RESULTS: Technical success rate of 312 procedures performed was 97.44% (304/312) with the mean fluoroscopy time of 12.68±7.34 minutes. Eight double J stent removal procedures failed, and all of these occurred in the position type D patients. The position type and the number of curls of the double J stent had a significant influence on the fluoroscopy time (P<0.05). In addition, multiple regression analysis demonstrated that the position type and number of curls in the double J stent were factors independently influenced the fluoroscopy time (P=0.001). Type D exhibited the longest fluoroscopy time followed by types B and C, and type A had the shortest fluoroscopy time. There were only minor complications consisting of urethral orifice pain (5.1%, 16/312) or gross hematuria (3.2%, 10/312), all resolved conservatively within 24 hours. CONCLUSIONS: The position type and the number of curls in a double J stent have a significant influence on the effectiveness of retrograde removal of double J stents using a simple snare technique in female patients.