Cargando…

The Effect of Footwear, Running Speed, and Location on the Validity of Two Commercially Available Inertial Measurement Units During Running

Introduction: Most running-related injuries are believed to be caused by abrupt changes in training load, compounded by biomechanical movement patterns. Wearable technology has made it possible for runners to quantify biomechanical loads (e.g., peak positive acceleration; PPA) using commercially ava...

Descripción completa

Detalles Bibliográficos
Autores principales: Napier, Christopher, Willy, Richard W., Hannigan, Brett C., McCann, Ryan, Menon, Carlo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8107270/
https://www.ncbi.nlm.nih.gov/pubmed/33981991
http://dx.doi.org/10.3389/fspor.2021.643385
_version_ 1783689923364126720
author Napier, Christopher
Willy, Richard W.
Hannigan, Brett C.
McCann, Ryan
Menon, Carlo
author_facet Napier, Christopher
Willy, Richard W.
Hannigan, Brett C.
McCann, Ryan
Menon, Carlo
author_sort Napier, Christopher
collection PubMed
description Introduction: Most running-related injuries are believed to be caused by abrupt changes in training load, compounded by biomechanical movement patterns. Wearable technology has made it possible for runners to quantify biomechanical loads (e.g., peak positive acceleration; PPA) using commercially available inertial measurement units (IMUs). However, few devices have established criterion validity. The aim of this study was to assess the validity of two commercially available IMUs during running. Secondary aims were to determine the effect of footwear, running speed, and IMU location on PPA. Materials and Methods: Healthy runners underwent a biomechanical running analysis on an instrumented treadmill. Participants ran at their preferred speed in three footwear conditions (neutral, minimalist, and maximalist), and at three speeds (preferred, +10%, −10%) in the neutral running shoes. Four IMUs were affixed at the distal tibia (IMeasureU-Tibia), shoelaces (RunScribe and IMeasureU-Shoe), and insole (Plantiga) of the right shoe. Pearson correlations were calculated for average vertical loading rate (AVLR) and PPA at each IMU location. Results: The AVLR had a high positive association with PPA (IMeasureU-Tibia) in the neutral and maximalist (r = 0.70–0.72; p ≤ 0.001) shoes and in all running speed conditions (r = 0.71–0.83; p ≤ 0.001), but low positive association in the minimalist (r = 0.47; p < 0.05) footwear condition. Conversely, the relationship between AVLR and PPA (Plantiga) was high in the minimalist (r = 0.75; p ≤ 0.001) condition and moderate in the neutral (r = 0.50; p < 0.05) and maximalist (r = 0.57; p < 0.01) footwear. The RunScribe metrics demonstrated low to moderate positive associations (r = 0.40–0.62; p < 0.05) with AVLR across most footwear and speed conditions. Discussion: Our findings indicate that the commercially available Plantiga IMU is comparable to a tibia-mounted IMU when acting as a surrogate for AVLR. However, these results vary between different levels of footwear and running speeds. The shoe-mounted RunScribe IMU exhibited slightly lower positive associations with AVLR. In general, the relationship with AVLR improved for the RunScribe sensor at slower speeds and improved for the Plantiga and tibia-mounted IMeasureU sensors at faster speeds.
format Online
Article
Text
id pubmed-8107270
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-81072702021-05-11 The Effect of Footwear, Running Speed, and Location on the Validity of Two Commercially Available Inertial Measurement Units During Running Napier, Christopher Willy, Richard W. Hannigan, Brett C. McCann, Ryan Menon, Carlo Front Sports Act Living Sports and Active Living Introduction: Most running-related injuries are believed to be caused by abrupt changes in training load, compounded by biomechanical movement patterns. Wearable technology has made it possible for runners to quantify biomechanical loads (e.g., peak positive acceleration; PPA) using commercially available inertial measurement units (IMUs). However, few devices have established criterion validity. The aim of this study was to assess the validity of two commercially available IMUs during running. Secondary aims were to determine the effect of footwear, running speed, and IMU location on PPA. Materials and Methods: Healthy runners underwent a biomechanical running analysis on an instrumented treadmill. Participants ran at their preferred speed in three footwear conditions (neutral, minimalist, and maximalist), and at three speeds (preferred, +10%, −10%) in the neutral running shoes. Four IMUs were affixed at the distal tibia (IMeasureU-Tibia), shoelaces (RunScribe and IMeasureU-Shoe), and insole (Plantiga) of the right shoe. Pearson correlations were calculated for average vertical loading rate (AVLR) and PPA at each IMU location. Results: The AVLR had a high positive association with PPA (IMeasureU-Tibia) in the neutral and maximalist (r = 0.70–0.72; p ≤ 0.001) shoes and in all running speed conditions (r = 0.71–0.83; p ≤ 0.001), but low positive association in the minimalist (r = 0.47; p < 0.05) footwear condition. Conversely, the relationship between AVLR and PPA (Plantiga) was high in the minimalist (r = 0.75; p ≤ 0.001) condition and moderate in the neutral (r = 0.50; p < 0.05) and maximalist (r = 0.57; p < 0.01) footwear. The RunScribe metrics demonstrated low to moderate positive associations (r = 0.40–0.62; p < 0.05) with AVLR across most footwear and speed conditions. Discussion: Our findings indicate that the commercially available Plantiga IMU is comparable to a tibia-mounted IMU when acting as a surrogate for AVLR. However, these results vary between different levels of footwear and running speeds. The shoe-mounted RunScribe IMU exhibited slightly lower positive associations with AVLR. In general, the relationship with AVLR improved for the RunScribe sensor at slower speeds and improved for the Plantiga and tibia-mounted IMeasureU sensors at faster speeds. Frontiers Media S.A. 2021-04-26 /pmc/articles/PMC8107270/ /pubmed/33981991 http://dx.doi.org/10.3389/fspor.2021.643385 Text en Copyright © 2021 Napier, Willy, Hannigan, McCann and Menon. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Sports and Active Living
Napier, Christopher
Willy, Richard W.
Hannigan, Brett C.
McCann, Ryan
Menon, Carlo
The Effect of Footwear, Running Speed, and Location on the Validity of Two Commercially Available Inertial Measurement Units During Running
title The Effect of Footwear, Running Speed, and Location on the Validity of Two Commercially Available Inertial Measurement Units During Running
title_full The Effect of Footwear, Running Speed, and Location on the Validity of Two Commercially Available Inertial Measurement Units During Running
title_fullStr The Effect of Footwear, Running Speed, and Location on the Validity of Two Commercially Available Inertial Measurement Units During Running
title_full_unstemmed The Effect of Footwear, Running Speed, and Location on the Validity of Two Commercially Available Inertial Measurement Units During Running
title_short The Effect of Footwear, Running Speed, and Location on the Validity of Two Commercially Available Inertial Measurement Units During Running
title_sort effect of footwear, running speed, and location on the validity of two commercially available inertial measurement units during running
topic Sports and Active Living
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8107270/
https://www.ncbi.nlm.nih.gov/pubmed/33981991
http://dx.doi.org/10.3389/fspor.2021.643385
work_keys_str_mv AT napierchristopher theeffectoffootwearrunningspeedandlocationonthevalidityoftwocommerciallyavailableinertialmeasurementunitsduringrunning
AT willyrichardw theeffectoffootwearrunningspeedandlocationonthevalidityoftwocommerciallyavailableinertialmeasurementunitsduringrunning
AT hanniganbrettc theeffectoffootwearrunningspeedandlocationonthevalidityoftwocommerciallyavailableinertialmeasurementunitsduringrunning
AT mccannryan theeffectoffootwearrunningspeedandlocationonthevalidityoftwocommerciallyavailableinertialmeasurementunitsduringrunning
AT menoncarlo theeffectoffootwearrunningspeedandlocationonthevalidityoftwocommerciallyavailableinertialmeasurementunitsduringrunning
AT napierchristopher effectoffootwearrunningspeedandlocationonthevalidityoftwocommerciallyavailableinertialmeasurementunitsduringrunning
AT willyrichardw effectoffootwearrunningspeedandlocationonthevalidityoftwocommerciallyavailableinertialmeasurementunitsduringrunning
AT hanniganbrettc effectoffootwearrunningspeedandlocationonthevalidityoftwocommerciallyavailableinertialmeasurementunitsduringrunning
AT mccannryan effectoffootwearrunningspeedandlocationonthevalidityoftwocommerciallyavailableinertialmeasurementunitsduringrunning
AT menoncarlo effectoffootwearrunningspeedandlocationonthevalidityoftwocommerciallyavailableinertialmeasurementunitsduringrunning