Cargando…

Safety and efficacy of an implantable device for management of gastroesophageal reflux in lung transplant recipients

BACKGROUND: Magnetic sphincter augmentation (MSA) is a promising minimally invasive surgical technique for management of gastroesophageal reflux disease (GERD); however, device implantation after transplantation has not been studied and may be concerning in these immunosuppressed patients. We explor...

Descripción completa

Detalles Bibliográficos
Autores principales: Halpern, Samantha E., Gupta, Aryaman, Jawitz, Oliver K., Choi, Ashley Y., Salfity, Hai V., Klapper, Jacob A., Hartwig, Matthew G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8107527/
https://www.ncbi.nlm.nih.gov/pubmed/34012562
http://dx.doi.org/10.21037/jtd-20-3276
Descripción
Sumario:BACKGROUND: Magnetic sphincter augmentation (MSA) is a promising minimally invasive surgical technique for management of gastroesophageal reflux disease (GERD); however, device implantation after transplantation has not been studied and may be concerning in these immunosuppressed patients. We explored the safety of the LINX Reflux Management System (MSA device) for management of GERD following lung transplantation (LTx). METHODS: Lung transplant recipients who underwent LINX implantation at our institution between 2017 and 2019 were followed prospectively in the Reflux Following Lung Transplantation and Associated Treatment Registry. Ambulatory pH testing and acid-suppressing medication use were compared before and after LINX implantation. One-year outcomes and change in pulmonary function were compared between matched LINX and fundoplication groups. RESULTS: Of 17 patients who underwent post-lung transplant LINX implantation, 8 (47.1%) agreed to undergo post-LINX pH testing. Three/eight (37.5%) patients achieved normal esophageal acid exposure time; 14 (82.4%) remained on acid-suppressing medication at one-year under the direction of their transplant teams. One-year patient survival and change in pulmonary function were similar between groups. LINX patients experienced more early side effects. CONCLUSIONS: Use of the LINX MSA device in a cohort of lung transplant recipients at our institution was associated with similar short-term safety compared to traditional fundoplication, however assessment of efficacy was limited. Further investigation is needed to characterize the long-term efficacy of LINX implantation after LTx.