Dosimetric Evaluation of the QFix kVue(TM) Calypso Couch Top
PURPOSE: To evaluate the dosimetric accuracy of the default couch model of the QFix kVue(TM) Calypso couch top in the treatment planning system. METHODS: With the gantry 180°, field size 20 × 20 cm, 6 MV, we measured the depth dose, off-axis dose, and dose plane of different depths in the phantom wi...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8107663/ https://www.ncbi.nlm.nih.gov/pubmed/33910440 http://dx.doi.org/10.1177/15330338211011964 |
_version_ | 1783689990108086272 |
---|---|
author | Hou, Lingtong Zhang, Huiqin Sun, Xiaomei Liu, Qianqian Chen, Tingfeng Liu, Yong Jiang, Xiaodong Yao, Shengyu |
author_facet | Hou, Lingtong Zhang, Huiqin Sun, Xiaomei Liu, Qianqian Chen, Tingfeng Liu, Yong Jiang, Xiaodong Yao, Shengyu |
author_sort | Hou, Lingtong |
collection | PubMed |
description | PURPOSE: To evaluate the dosimetric accuracy of the default couch model of the QFix kVue(TM) Calypso couch top in the treatment planning system. METHODS: With the gantry 180°, field size 20 × 20 cm, 6 MV, we measured the depth dose, off-axis dose, and dose plane of different depths in the phantom with the couch rails in and out, respectively. Isocenter doses at different angles were also obtained. The results were compared to the doses calculated using the default couch top model and the real scanned couch top model. Then we revised the default model according to the measured results. RESULTS: With “Rails In,” the depth dose, off-axis dose, and dose plane of the default couch top model had a big difference with the dose of the real scanned couch top model and the measured result. The dose of the real scanned couch top model was much closer to the measured result, but in the region of the rail edge, the difference was still significant. With “Rails Out,” there was a minor difference between the measured result, the dose of the default couch top model and the real scanned couch top model. The difference between the measurement and the default couch top model became very small after being revised. CONCLUSIONS: It is better to avoid the beam angle passing through the couch rails in treatment plans, or you should revise the parameter of the QFix kVue(TM) Calypso couch top model based on the measured results, and verify the treatment plan before clinical practice. |
format | Online Article Text |
id | pubmed-8107663 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-81076632021-05-14 Dosimetric Evaluation of the QFix kVue(TM) Calypso Couch Top Hou, Lingtong Zhang, Huiqin Sun, Xiaomei Liu, Qianqian Chen, Tingfeng Liu, Yong Jiang, Xiaodong Yao, Shengyu Technol Cancer Res Treat Original Article PURPOSE: To evaluate the dosimetric accuracy of the default couch model of the QFix kVue(TM) Calypso couch top in the treatment planning system. METHODS: With the gantry 180°, field size 20 × 20 cm, 6 MV, we measured the depth dose, off-axis dose, and dose plane of different depths in the phantom with the couch rails in and out, respectively. Isocenter doses at different angles were also obtained. The results were compared to the doses calculated using the default couch top model and the real scanned couch top model. Then we revised the default model according to the measured results. RESULTS: With “Rails In,” the depth dose, off-axis dose, and dose plane of the default couch top model had a big difference with the dose of the real scanned couch top model and the measured result. The dose of the real scanned couch top model was much closer to the measured result, but in the region of the rail edge, the difference was still significant. With “Rails Out,” there was a minor difference between the measured result, the dose of the default couch top model and the real scanned couch top model. The difference between the measurement and the default couch top model became very small after being revised. CONCLUSIONS: It is better to avoid the beam angle passing through the couch rails in treatment plans, or you should revise the parameter of the QFix kVue(TM) Calypso couch top model based on the measured results, and verify the treatment plan before clinical practice. SAGE Publications 2021-04-29 /pmc/articles/PMC8107663/ /pubmed/33910440 http://dx.doi.org/10.1177/15330338211011964 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Article Hou, Lingtong Zhang, Huiqin Sun, Xiaomei Liu, Qianqian Chen, Tingfeng Liu, Yong Jiang, Xiaodong Yao, Shengyu Dosimetric Evaluation of the QFix kVue(TM) Calypso Couch Top |
title | Dosimetric Evaluation of the QFix kVue(TM) Calypso Couch Top |
title_full | Dosimetric Evaluation of the QFix kVue(TM) Calypso Couch Top |
title_fullStr | Dosimetric Evaluation of the QFix kVue(TM) Calypso Couch Top |
title_full_unstemmed | Dosimetric Evaluation of the QFix kVue(TM) Calypso Couch Top |
title_short | Dosimetric Evaluation of the QFix kVue(TM) Calypso Couch Top |
title_sort | dosimetric evaluation of the qfix kvue(tm) calypso couch top |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8107663/ https://www.ncbi.nlm.nih.gov/pubmed/33910440 http://dx.doi.org/10.1177/15330338211011964 |
work_keys_str_mv | AT houlingtong dosimetricevaluationoftheqfixkvuetmcalypsocouchtop AT zhanghuiqin dosimetricevaluationoftheqfixkvuetmcalypsocouchtop AT sunxiaomei dosimetricevaluationoftheqfixkvuetmcalypsocouchtop AT liuqianqian dosimetricevaluationoftheqfixkvuetmcalypsocouchtop AT chentingfeng dosimetricevaluationoftheqfixkvuetmcalypsocouchtop AT liuyong dosimetricevaluationoftheqfixkvuetmcalypsocouchtop AT jiangxiaodong dosimetricevaluationoftheqfixkvuetmcalypsocouchtop AT yaoshengyu dosimetricevaluationoftheqfixkvuetmcalypsocouchtop |