Cargando…

Two-Year Comparative Outcomes of First- and Second-Generation Trabecular Micro-Bypass Stents with Cataract Surgery

INTRODUCTION: This retrospective comparative study assessed real-world effectiveness and safety of first-generation (iStent(®)) and second-generation (iStent inject(®)) trabecular micro-bypass stents with cataract surgery in patients with open-angle glaucoma (OAG). MATERIAL AND METHODS: Through a 24...

Descripción completa

Detalles Bibliográficos
Autores principales: Paletta Guedes, Ricardo Augusto, Gravina, Daniela Marcelo, Paletta Guedes, Vanessa Maria, Chaoubah, Alfredo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8108397/
https://www.ncbi.nlm.nih.gov/pubmed/33981138
http://dx.doi.org/10.2147/OPTH.S302684
Descripción
Sumario:INTRODUCTION: This retrospective comparative study assessed real-world effectiveness and safety of first-generation (iStent(®)) and second-generation (iStent inject(®)) trabecular micro-bypass stents with cataract surgery in patients with open-angle glaucoma (OAG). MATERIAL AND METHODS: Through a 24-month postoperative follow-up, the effectiveness was quantified by intraocular pressure (IOP) reduction; mean glaucoma medication reduction; proportional analysis of eyes meeting IOP cutoffs (<18, <15, <12 mmHg) either with or without medications; and proportional analysis of medication burden. Safety measures included visual acuity, adverse events, and secondary surgery. RESULTS: A total of 82 consecutive eyes (39 iStent, 43 iStent inject) with a 24-month follow-up were analyzed. Most eyes (74.4%) had primary open-angle glaucoma, with the remainder having pseudoexfoliative or pigmentary glaucoma; all eyes had mild-to-moderate disease. At 24 months postoperative, the mean IOP was lower, and the percent reduction from baseline was greater, in iStent inject eyes (26.0% reduction, 17.7mmHg to 13.1mmHg) than in iStent eyes (9.8% reduction, 16.4mmHg to 14.8mmHg) (between-groups comparison, p=0.019). Within each group, the postoperative IOP reduction was greater in eyes with higher baseline IOP (p<0.001). Medication burden decreased significantly in both groups, from 1.74 to 0.51 mean medications for iStent (70.7% reduction, p<0.0001), and 2.19 to 0.65 for iStent inject (70.3% reduction, p<0.0001). Both groups exhibited excellent safety. CONCLUSION: iStent or iStent inject with phacoemulsification produced significant IOP and medication reductions, with effects enduring for two years. IOP reductions were greater for iStent inject than for iStent. Within each group, higher preoperative IOP was associated with greater postoperative IOP reduction.