Cargando…
Does Low-Magnitude High-Frequency Vibration (LMHFV) Worth for Clinical Trial on Dental Implant? A Systematic Review and Meta-Analysis on Animal Studies
Being as a non-pharmacological medical intervention, low-magnitude high-frequency vibration (LMHFV) has shown a positive effect on bone induction and remodeling for various muscle diseases in animal studies, among which dental implants osteointegration were reported to be improved as well. However,...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8111077/ https://www.ncbi.nlm.nih.gov/pubmed/33987172 http://dx.doi.org/10.3389/fbioe.2021.626892 |
_version_ | 1783690427618033664 |
---|---|
author | Ye, Xinjian Gu, Ying Bai, Yijing Xia, Siqi Zhang, Yujia Lou, Yuwei Zhu, Yuchi Dai, Yuwei Tsoi, James Kit-Hon Wang, Shuhua |
author_facet | Ye, Xinjian Gu, Ying Bai, Yijing Xia, Siqi Zhang, Yujia Lou, Yuwei Zhu, Yuchi Dai, Yuwei Tsoi, James Kit-Hon Wang, Shuhua |
author_sort | Ye, Xinjian |
collection | PubMed |
description | Being as a non-pharmacological medical intervention, low-magnitude high-frequency vibration (LMHFV) has shown a positive effect on bone induction and remodeling for various muscle diseases in animal studies, among which dental implants osteointegration were reported to be improved as well. However, whether LMHFV can be clinically used in dental implant is still unknown. In this study, efficacy, parameters and side effects of LMHFV were analyzed via data before 15th July 2020, collecting from MEDLINE/PubMed, Embase, Ovid and Cochrane Library databases. In the screened 1,742 abstracts and 45 articles, 15 animal studies involving 972 implants were included. SYRCLE's tool was performed to assess the possible risk of bias for each study. The GRADE approach was applied to evaluate the quality of evidence. Random effects meta-analysis detected statistically significant in total BIC (P < 0.0001) and BV/TV (P = 0.001) upon loading LMHFV on implants. To conclude, LMHFV played an active role on BIC and BV/TV data according to the GRADE analysis results (medium and low quality of evidence). This might illustrate LMHFV to be a worthy way in improving osseointegration clinically, especially for osteoporosis. Systematic Review Registration: https://www.crd.york.ac.uk/PROSPERO, identifier: NCT02612389 |
format | Online Article Text |
id | pubmed-8111077 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-81110772021-05-12 Does Low-Magnitude High-Frequency Vibration (LMHFV) Worth for Clinical Trial on Dental Implant? A Systematic Review and Meta-Analysis on Animal Studies Ye, Xinjian Gu, Ying Bai, Yijing Xia, Siqi Zhang, Yujia Lou, Yuwei Zhu, Yuchi Dai, Yuwei Tsoi, James Kit-Hon Wang, Shuhua Front Bioeng Biotechnol Bioengineering and Biotechnology Being as a non-pharmacological medical intervention, low-magnitude high-frequency vibration (LMHFV) has shown a positive effect on bone induction and remodeling for various muscle diseases in animal studies, among which dental implants osteointegration were reported to be improved as well. However, whether LMHFV can be clinically used in dental implant is still unknown. In this study, efficacy, parameters and side effects of LMHFV were analyzed via data before 15th July 2020, collecting from MEDLINE/PubMed, Embase, Ovid and Cochrane Library databases. In the screened 1,742 abstracts and 45 articles, 15 animal studies involving 972 implants were included. SYRCLE's tool was performed to assess the possible risk of bias for each study. The GRADE approach was applied to evaluate the quality of evidence. Random effects meta-analysis detected statistically significant in total BIC (P < 0.0001) and BV/TV (P = 0.001) upon loading LMHFV on implants. To conclude, LMHFV played an active role on BIC and BV/TV data according to the GRADE analysis results (medium and low quality of evidence). This might illustrate LMHFV to be a worthy way in improving osseointegration clinically, especially for osteoporosis. Systematic Review Registration: https://www.crd.york.ac.uk/PROSPERO, identifier: NCT02612389 Frontiers Media S.A. 2021-04-27 /pmc/articles/PMC8111077/ /pubmed/33987172 http://dx.doi.org/10.3389/fbioe.2021.626892 Text en Copyright © 2021 Ye, Gu, Bai, Xia, Zhang, Lou, Zhu, Dai, Tsoi and Wang. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Bioengineering and Biotechnology Ye, Xinjian Gu, Ying Bai, Yijing Xia, Siqi Zhang, Yujia Lou, Yuwei Zhu, Yuchi Dai, Yuwei Tsoi, James Kit-Hon Wang, Shuhua Does Low-Magnitude High-Frequency Vibration (LMHFV) Worth for Clinical Trial on Dental Implant? A Systematic Review and Meta-Analysis on Animal Studies |
title | Does Low-Magnitude High-Frequency Vibration (LMHFV) Worth for Clinical Trial on Dental Implant? A Systematic Review and Meta-Analysis on Animal Studies |
title_full | Does Low-Magnitude High-Frequency Vibration (LMHFV) Worth for Clinical Trial on Dental Implant? A Systematic Review and Meta-Analysis on Animal Studies |
title_fullStr | Does Low-Magnitude High-Frequency Vibration (LMHFV) Worth for Clinical Trial on Dental Implant? A Systematic Review and Meta-Analysis on Animal Studies |
title_full_unstemmed | Does Low-Magnitude High-Frequency Vibration (LMHFV) Worth for Clinical Trial on Dental Implant? A Systematic Review and Meta-Analysis on Animal Studies |
title_short | Does Low-Magnitude High-Frequency Vibration (LMHFV) Worth for Clinical Trial on Dental Implant? A Systematic Review and Meta-Analysis on Animal Studies |
title_sort | does low-magnitude high-frequency vibration (lmhfv) worth for clinical trial on dental implant? a systematic review and meta-analysis on animal studies |
topic | Bioengineering and Biotechnology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8111077/ https://www.ncbi.nlm.nih.gov/pubmed/33987172 http://dx.doi.org/10.3389/fbioe.2021.626892 |
work_keys_str_mv | AT yexinjian doeslowmagnitudehighfrequencyvibrationlmhfvworthforclinicaltrialondentalimplantasystematicreviewandmetaanalysisonanimalstudies AT guying doeslowmagnitudehighfrequencyvibrationlmhfvworthforclinicaltrialondentalimplantasystematicreviewandmetaanalysisonanimalstudies AT baiyijing doeslowmagnitudehighfrequencyvibrationlmhfvworthforclinicaltrialondentalimplantasystematicreviewandmetaanalysisonanimalstudies AT xiasiqi doeslowmagnitudehighfrequencyvibrationlmhfvworthforclinicaltrialondentalimplantasystematicreviewandmetaanalysisonanimalstudies AT zhangyujia doeslowmagnitudehighfrequencyvibrationlmhfvworthforclinicaltrialondentalimplantasystematicreviewandmetaanalysisonanimalstudies AT louyuwei doeslowmagnitudehighfrequencyvibrationlmhfvworthforclinicaltrialondentalimplantasystematicreviewandmetaanalysisonanimalstudies AT zhuyuchi doeslowmagnitudehighfrequencyvibrationlmhfvworthforclinicaltrialondentalimplantasystematicreviewandmetaanalysisonanimalstudies AT daiyuwei doeslowmagnitudehighfrequencyvibrationlmhfvworthforclinicaltrialondentalimplantasystematicreviewandmetaanalysisonanimalstudies AT tsoijameskithon doeslowmagnitudehighfrequencyvibrationlmhfvworthforclinicaltrialondentalimplantasystematicreviewandmetaanalysisonanimalstudies AT wangshuhua doeslowmagnitudehighfrequencyvibrationlmhfvworthforclinicaltrialondentalimplantasystematicreviewandmetaanalysisonanimalstudies |