Cargando…

Patient Controlled, Off-label Use of Continuous Glucose Monitoring: Real-World Medical Costs and Effects of Patient Controlled Sensor Augmented Pump Therapy in Adult Patients Type 1 Diabetes

BACKGROUND: Continuous glucose monitoring (CGM) has shown promise to reduce glycated hemoglobin (HbA1c) levels, but its cost-effectiveness is seen as uncertain by reimbursement agencies. The aim of this study was to explore the impact of real-world, off-label, patient controlled CGM use in combinati...

Descripción completa

Detalles Bibliográficos
Autores principales: Hidefjäll, Patrik, Berg, Lars
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8111228/
https://www.ncbi.nlm.nih.gov/pubmed/32517514
http://dx.doi.org/10.1177/1932296820920909
Descripción
Sumario:BACKGROUND: Continuous glucose monitoring (CGM) has shown promise to reduce glycated hemoglobin (HbA1c) levels, but its cost-effectiveness is seen as uncertain by reimbursement agencies. The aim of this study was to explore the impact of real-world, off-label, patient controlled CGM use in combination with continuous subcutaneous insulin infusion (CSII) on costs and effects in patients with type 1 diabetes in a Swedish clinic. METHODS: A real-world, retrospective study with questionnaire on CGM use by adult patients with type 1 diabetes on CSII (Animas Vibe) were offered sensor augmented pump therapy (SAPT) (Dexcom G4) as part of hospital innovation funding program. Direct medical costs, HbA1c, and complications following switch from CSII with self-monitoring of blood glucose (SMBG) to SAPT were calculated. RESULTS: Questionnaire data showed that CGM sensors were on average used 92% of the time for 22 days. One hundred and thirty-nine (95%) of 146 respondents used each sensor for longer than one week. Data analysis showed a statistically significant HbA1c decrease of 0.56% (6.1 mmol/mol) after change to SAPT. In patients using the sensor 100%, the decrease was 0.89% (9.8 mmol/mol). The analysis showed that SAPT led to higher costs (5500 USD/year) than CSII + SMBG (3680 USD/year), with incremental costs being 1815 USD per year to achieve an HbA1c decrease of 0.56% (6.1 mmol/mol). The incidence of all complications declined after switch to SAPT. CONCLUSION: The primary data analysis showed a decrease in HbA1c values following switch to SAPT, corresponding to previous cost-effectiveness studies, but at substantially lower costs due to longer sensor off-label use.