3D angle-independent Doppler and speckle tracking for the myocardium and blood flow

A technology based on velocity ratio indices is described for application in the myocardium. Angle-independent Doppler indices, such as the pulsatility index, which employ velocity ratios, can be measured even if the ultrasound beam vector at the moving target and the motion vector are not in a know...

Descripción completa

Detalles Bibliográficos
Autores principales: McDicken, Norman, Thomson, Adrian, White, Audrey, Toor, Iqbal, Gray, Gillian, Moran, Carmel, Watson, Robin J, Anderson, Tom
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bioscientifica Ltd 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8111307/
https://www.ncbi.nlm.nih.gov/pubmed/31729209
http://dx.doi.org/10.1530/ERP-19-0040
_version_ 1783690472053538816
author McDicken, Norman
Thomson, Adrian
White, Audrey
Toor, Iqbal
Gray, Gillian
Moran, Carmel
Watson, Robin J
Anderson, Tom
author_facet McDicken, Norman
Thomson, Adrian
White, Audrey
Toor, Iqbal
Gray, Gillian
Moran, Carmel
Watson, Robin J
Anderson, Tom
author_sort McDicken, Norman
collection PubMed
description A technology based on velocity ratio indices is described for application in the myocardium. Angle-independent Doppler indices, such as the pulsatility index, which employ velocity ratios, can be measured even if the ultrasound beam vector at the moving target and the motion vector are not in a known plane. The unknown plane situation is often encountered when an ultrasound beam interrogates sites in the myocardium. The velocities employed in an index calculation must be close to the same or opposite directions. The Doppler velocity ratio indices are independent of angle in 3D space as are ratio indices based on 1D strain and 1D speckle tracking. Angle-independent results with spectral Doppler methods are discussed. Possible future imaging techniques based on velocity ratios are presented. By using indices that involve ratios, several other sources of error cancel in addition to that of angular dependence for example errors due to less than optimum gain settings and beam distortion. This makes the indices reliable as research or clinical tools. Ratio techniques can be readily implemented with current commercial blood flow pulsed wave duplex Doppler equipment or with pulsed wave tissue Doppler equipment. In 70 patients where the quality of the real-time B-mode looked suitable for the Doppler velocity ratio technique, there was only one case where clear spectra could not be obtained for both the LV wall and the septum. A reproducibility study of spectra from the septum of the heart shows a 12% difference in velocity ratios in the repeat measurements.
format Online
Article
Text
id pubmed-8111307
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Bioscientifica Ltd
record_format MEDLINE/PubMed
spelling pubmed-81113072021-05-13 3D angle-independent Doppler and speckle tracking for the myocardium and blood flow McDicken, Norman Thomson, Adrian White, Audrey Toor, Iqbal Gray, Gillian Moran, Carmel Watson, Robin J Anderson, Tom Echo Res Pract Research A technology based on velocity ratio indices is described for application in the myocardium. Angle-independent Doppler indices, such as the pulsatility index, which employ velocity ratios, can be measured even if the ultrasound beam vector at the moving target and the motion vector are not in a known plane. The unknown plane situation is often encountered when an ultrasound beam interrogates sites in the myocardium. The velocities employed in an index calculation must be close to the same or opposite directions. The Doppler velocity ratio indices are independent of angle in 3D space as are ratio indices based on 1D strain and 1D speckle tracking. Angle-independent results with spectral Doppler methods are discussed. Possible future imaging techniques based on velocity ratios are presented. By using indices that involve ratios, several other sources of error cancel in addition to that of angular dependence for example errors due to less than optimum gain settings and beam distortion. This makes the indices reliable as research or clinical tools. Ratio techniques can be readily implemented with current commercial blood flow pulsed wave duplex Doppler equipment or with pulsed wave tissue Doppler equipment. In 70 patients where the quality of the real-time B-mode looked suitable for the Doppler velocity ratio technique, there was only one case where clear spectra could not be obtained for both the LV wall and the septum. A reproducibility study of spectra from the septum of the heart shows a 12% difference in velocity ratios in the repeat measurements. Bioscientifica Ltd 2019-09-27 /pmc/articles/PMC8111307/ /pubmed/31729209 http://dx.doi.org/10.1530/ERP-19-0040 Text en © 2019 The authors https://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research
McDicken, Norman
Thomson, Adrian
White, Audrey
Toor, Iqbal
Gray, Gillian
Moran, Carmel
Watson, Robin J
Anderson, Tom
3D angle-independent Doppler and speckle tracking for the myocardium and blood flow
title 3D angle-independent Doppler and speckle tracking for the myocardium and blood flow
title_full 3D angle-independent Doppler and speckle tracking for the myocardium and blood flow
title_fullStr 3D angle-independent Doppler and speckle tracking for the myocardium and blood flow
title_full_unstemmed 3D angle-independent Doppler and speckle tracking for the myocardium and blood flow
title_short 3D angle-independent Doppler and speckle tracking for the myocardium and blood flow
title_sort 3d angle-independent doppler and speckle tracking for the myocardium and blood flow
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8111307/
https://www.ncbi.nlm.nih.gov/pubmed/31729209
http://dx.doi.org/10.1530/ERP-19-0040
work_keys_str_mv AT mcdickennorman 3dangleindependentdopplerandspeckletrackingforthemyocardiumandbloodflow
AT thomsonadrian 3dangleindependentdopplerandspeckletrackingforthemyocardiumandbloodflow
AT whiteaudrey 3dangleindependentdopplerandspeckletrackingforthemyocardiumandbloodflow
AT tooriqbal 3dangleindependentdopplerandspeckletrackingforthemyocardiumandbloodflow
AT graygillian 3dangleindependentdopplerandspeckletrackingforthemyocardiumandbloodflow
AT morancarmel 3dangleindependentdopplerandspeckletrackingforthemyocardiumandbloodflow
AT watsonrobinj 3dangleindependentdopplerandspeckletrackingforthemyocardiumandbloodflow
AT andersontom 3dangleindependentdopplerandspeckletrackingforthemyocardiumandbloodflow