Effect of a figure-of-eight cerclage wire with two Kirschner wires on fixation strength for transverse metacarpal shaft fractures: an in vitro study with artificial bone

BACKGROUND: Metacarpal shaft fractures are a common type of hand fracture. Despite providing strong fixation strength, plate fixation has numerous shortcomings. Concerning internal fixation with Kirschner wires (K-wires), although this approach is frequently used to treat metacarpal shaft fractures,...

Descripción completa

Detalles Bibliográficos
Autores principales: Chiu, Yung-Cheng, Hsu, Cheng-En, Ho, Tsung-Yu, Ting, Yen-Nien, Tsai, Ming-Tzu, Hsu, Jui-Ting
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8112006/
https://www.ncbi.nlm.nih.gov/pubmed/33971840
http://dx.doi.org/10.1186/s12891-021-04276-8
_version_ 1783690609875222528
author Chiu, Yung-Cheng
Hsu, Cheng-En
Ho, Tsung-Yu
Ting, Yen-Nien
Tsai, Ming-Tzu
Hsu, Jui-Ting
author_facet Chiu, Yung-Cheng
Hsu, Cheng-En
Ho, Tsung-Yu
Ting, Yen-Nien
Tsai, Ming-Tzu
Hsu, Jui-Ting
author_sort Chiu, Yung-Cheng
collection PubMed
description BACKGROUND: Metacarpal shaft fractures are a common type of hand fracture. Despite providing strong fixation strength, plate fixation has numerous shortcomings. Concerning internal fixation with Kirschner wires (K-wires), although this approach is frequently used to treat metacarpal shaft fractures, the lack of functional stability may result in fixation failure. OBJECTIVE: To evaluate the effect of figure-of-eight cerclage wire on fixation for transverse metacarpal shaft fractures using two K-wires. MATERIALS AND METHODS: We used a saw blade to create transverse metacarpal shaft fractures in 14 fourth-generation artificial third metacarpal bones (Sawbones, Vashon, WA, USA), which were assigned to groups undergoing fixation with two K-wires (KP) or with two K-wires and figure-of-eight cerclage wire (KP&F8). All specimens were subjected to material testing, specifically cantilever bending tests. The maximum fracture force and stiffness of the two fixation types were determined on the basis of the force–displacement data. The Mann–Whitney U test was used to compare between-group differences in maximum fracture force and stiffness. RESULTS: The maximum fracture force of the KP group (median ± interquartile range = 97.30 ± 29.70 N) was significantly lower than that of the KP&F8 group (153.2 ± 69.50 N, p < 0.05; Figure 5a), with the median of the KP&F8 group exceeding that of the KP group by 57.5%. Similarly, stiffness was significantly lower in the KP group (18.14 ± 9.84 N/mm) than in the KP&F8 group (38.25 ± 23.49 N/mm; p < 0.05; Figure 5b), with the median of the KP&F8 group exceeding that of the KP group by 110.9%. CONCLUSION: The incorporation of a figure-of-eight cerclage wire increased the maximum fracture force and stiffness by 57.5 and 110.9%, respectively, compared with those achieved in standard two K-wire fixation. Therefore, hand surgeons are advised to consider the proposed approach to increase fixation strength.
format Online
Article
Text
id pubmed-8112006
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-81120062021-05-11 Effect of a figure-of-eight cerclage wire with two Kirschner wires on fixation strength for transverse metacarpal shaft fractures: an in vitro study with artificial bone Chiu, Yung-Cheng Hsu, Cheng-En Ho, Tsung-Yu Ting, Yen-Nien Tsai, Ming-Tzu Hsu, Jui-Ting BMC Musculoskelet Disord Research BACKGROUND: Metacarpal shaft fractures are a common type of hand fracture. Despite providing strong fixation strength, plate fixation has numerous shortcomings. Concerning internal fixation with Kirschner wires (K-wires), although this approach is frequently used to treat metacarpal shaft fractures, the lack of functional stability may result in fixation failure. OBJECTIVE: To evaluate the effect of figure-of-eight cerclage wire on fixation for transverse metacarpal shaft fractures using two K-wires. MATERIALS AND METHODS: We used a saw blade to create transverse metacarpal shaft fractures in 14 fourth-generation artificial third metacarpal bones (Sawbones, Vashon, WA, USA), which were assigned to groups undergoing fixation with two K-wires (KP) or with two K-wires and figure-of-eight cerclage wire (KP&F8). All specimens were subjected to material testing, specifically cantilever bending tests. The maximum fracture force and stiffness of the two fixation types were determined on the basis of the force–displacement data. The Mann–Whitney U test was used to compare between-group differences in maximum fracture force and stiffness. RESULTS: The maximum fracture force of the KP group (median ± interquartile range = 97.30 ± 29.70 N) was significantly lower than that of the KP&F8 group (153.2 ± 69.50 N, p < 0.05; Figure 5a), with the median of the KP&F8 group exceeding that of the KP group by 57.5%. Similarly, stiffness was significantly lower in the KP group (18.14 ± 9.84 N/mm) than in the KP&F8 group (38.25 ± 23.49 N/mm; p < 0.05; Figure 5b), with the median of the KP&F8 group exceeding that of the KP group by 110.9%. CONCLUSION: The incorporation of a figure-of-eight cerclage wire increased the maximum fracture force and stiffness by 57.5 and 110.9%, respectively, compared with those achieved in standard two K-wire fixation. Therefore, hand surgeons are advised to consider the proposed approach to increase fixation strength. BioMed Central 2021-05-10 /pmc/articles/PMC8112006/ /pubmed/33971840 http://dx.doi.org/10.1186/s12891-021-04276-8 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Chiu, Yung-Cheng
Hsu, Cheng-En
Ho, Tsung-Yu
Ting, Yen-Nien
Tsai, Ming-Tzu
Hsu, Jui-Ting
Effect of a figure-of-eight cerclage wire with two Kirschner wires on fixation strength for transverse metacarpal shaft fractures: an in vitro study with artificial bone
title Effect of a figure-of-eight cerclage wire with two Kirschner wires on fixation strength for transverse metacarpal shaft fractures: an in vitro study with artificial bone
title_full Effect of a figure-of-eight cerclage wire with two Kirschner wires on fixation strength for transverse metacarpal shaft fractures: an in vitro study with artificial bone
title_fullStr Effect of a figure-of-eight cerclage wire with two Kirschner wires on fixation strength for transverse metacarpal shaft fractures: an in vitro study with artificial bone
title_full_unstemmed Effect of a figure-of-eight cerclage wire with two Kirschner wires on fixation strength for transverse metacarpal shaft fractures: an in vitro study with artificial bone
title_short Effect of a figure-of-eight cerclage wire with two Kirschner wires on fixation strength for transverse metacarpal shaft fractures: an in vitro study with artificial bone
title_sort effect of a figure-of-eight cerclage wire with two kirschner wires on fixation strength for transverse metacarpal shaft fractures: an in vitro study with artificial bone
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8112006/
https://www.ncbi.nlm.nih.gov/pubmed/33971840
http://dx.doi.org/10.1186/s12891-021-04276-8
work_keys_str_mv AT chiuyungcheng effectofafigureofeightcerclagewirewithtwokirschnerwiresonfixationstrengthfortransversemetacarpalshaftfracturesaninvitrostudywithartificialbone
AT hsuchengen effectofafigureofeightcerclagewirewithtwokirschnerwiresonfixationstrengthfortransversemetacarpalshaftfracturesaninvitrostudywithartificialbone
AT hotsungyu effectofafigureofeightcerclagewirewithtwokirschnerwiresonfixationstrengthfortransversemetacarpalshaftfracturesaninvitrostudywithartificialbone
AT tingyennien effectofafigureofeightcerclagewirewithtwokirschnerwiresonfixationstrengthfortransversemetacarpalshaftfracturesaninvitrostudywithartificialbone
AT tsaimingtzu effectofafigureofeightcerclagewirewithtwokirschnerwiresonfixationstrengthfortransversemetacarpalshaftfracturesaninvitrostudywithartificialbone
AT hsujuiting effectofafigureofeightcerclagewirewithtwokirschnerwiresonfixationstrengthfortransversemetacarpalshaftfracturesaninvitrostudywithartificialbone