Comparative Evaluation of Accuracy of Different Apex Locators: Propex IQ, Raypex 6, Root ZX, and Apex ID with CBCT and Periapical Radiograph—In Vitro Study
OBJECTIVES: This study aimed to validate the accuracy of working length (WL) measurements obtained with the newly introduced Propex IQ apex locator and to compare it with the latest generations of other electronic apex locators, CBCT, and conventional periapical radiographs by using the actual WL me...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8112958/ https://www.ncbi.nlm.nih.gov/pubmed/34054960 http://dx.doi.org/10.1155/2021/5563426 |
_version_ | 1783690773050425344 |
---|---|
author | Mahmoud, Okba Awad Abdelmagied, Mawada Hassan Dandashi, Ahmad Hisham Jasim, Bakr Nssaief Tawfik Kayali, Hussam Alddin Al Shehadat, Saaid |
author_facet | Mahmoud, Okba Awad Abdelmagied, Mawada Hassan Dandashi, Ahmad Hisham Jasim, Bakr Nssaief Tawfik Kayali, Hussam Alddin Al Shehadat, Saaid |
author_sort | Mahmoud, Okba |
collection | PubMed |
description | OBJECTIVES: This study aimed to validate the accuracy of working length (WL) measurements obtained with the newly introduced Propex IQ apex locator and to compare it with the latest generations of other electronic apex locators, CBCT, and conventional periapical radiographs by using the actual WL measurements obtained by using an endodontics microscope as a reference. MATERIALS AND METHODS: Thirty-five extracted single-rooted human mandibular first premolars with curvatures from 10° to 20° were selected according to the inclusion and exclusion criteria and cut at the cementoenamel junction to achieve a standard reference point for WL determination. The actual WL was obtained by inserting a size-15 k-file in the root canal until the tip of the file was visible under an endodontic microscope. The definitive WL was measured using Propex IQ (Dentsply Sirona), Raypex 6 (VDW Dental), Root ZX (Morita), and Apex ID (Kerr Dental). In addition, radiographic WL was obtained using periapical radiographs and CBCT. One-way ANOVA was used for comparisons of the WL values, with a p value < 0.05. The percentage of success of each method for determination of the definitive WL was assessed using cross-tabulation and chi-square tests. RESULTS: CBCT radiographs and Propex IQ apex locator yielded the most accurate WL measurements in comparison with the actual WL measurements (p < 0.05). Raypex 6, Root ZX, and Apex ID yielded more accurate WL measurements than conventional periapical radiographs (p < 0.05). Periapical radiographs yielded the least accurate WL measurements in comparison with the actual WL values (p < 0.05). CONCLUSIONS: Within the limitations of this study, the Propex IQ apex locator showed higher accuracy than Raypex 6, Root ZX, and Apex ID for WL determination in the root canal. Nevertheless, CBCT radiographs yielded the maximum accuracy for WL measurements. |
format | Online Article Text |
id | pubmed-8112958 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-81129582021-05-27 Comparative Evaluation of Accuracy of Different Apex Locators: Propex IQ, Raypex 6, Root ZX, and Apex ID with CBCT and Periapical Radiograph—In Vitro Study Mahmoud, Okba Awad Abdelmagied, Mawada Hassan Dandashi, Ahmad Hisham Jasim, Bakr Nssaief Tawfik Kayali, Hussam Alddin Al Shehadat, Saaid Int J Dent Research Article OBJECTIVES: This study aimed to validate the accuracy of working length (WL) measurements obtained with the newly introduced Propex IQ apex locator and to compare it with the latest generations of other electronic apex locators, CBCT, and conventional periapical radiographs by using the actual WL measurements obtained by using an endodontics microscope as a reference. MATERIALS AND METHODS: Thirty-five extracted single-rooted human mandibular first premolars with curvatures from 10° to 20° were selected according to the inclusion and exclusion criteria and cut at the cementoenamel junction to achieve a standard reference point for WL determination. The actual WL was obtained by inserting a size-15 k-file in the root canal until the tip of the file was visible under an endodontic microscope. The definitive WL was measured using Propex IQ (Dentsply Sirona), Raypex 6 (VDW Dental), Root ZX (Morita), and Apex ID (Kerr Dental). In addition, radiographic WL was obtained using periapical radiographs and CBCT. One-way ANOVA was used for comparisons of the WL values, with a p value < 0.05. The percentage of success of each method for determination of the definitive WL was assessed using cross-tabulation and chi-square tests. RESULTS: CBCT radiographs and Propex IQ apex locator yielded the most accurate WL measurements in comparison with the actual WL measurements (p < 0.05). Raypex 6, Root ZX, and Apex ID yielded more accurate WL measurements than conventional periapical radiographs (p < 0.05). Periapical radiographs yielded the least accurate WL measurements in comparison with the actual WL values (p < 0.05). CONCLUSIONS: Within the limitations of this study, the Propex IQ apex locator showed higher accuracy than Raypex 6, Root ZX, and Apex ID for WL determination in the root canal. Nevertheless, CBCT radiographs yielded the maximum accuracy for WL measurements. Hindawi 2021-05-04 /pmc/articles/PMC8112958/ /pubmed/34054960 http://dx.doi.org/10.1155/2021/5563426 Text en Copyright © 2021 Okba Mahmoud et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Mahmoud, Okba Awad Abdelmagied, Mawada Hassan Dandashi, Ahmad Hisham Jasim, Bakr Nssaief Tawfik Kayali, Hussam Alddin Al Shehadat, Saaid Comparative Evaluation of Accuracy of Different Apex Locators: Propex IQ, Raypex 6, Root ZX, and Apex ID with CBCT and Periapical Radiograph—In Vitro Study |
title | Comparative Evaluation of Accuracy of Different Apex Locators: Propex IQ, Raypex 6, Root ZX, and Apex ID with CBCT and Periapical Radiograph—In Vitro Study |
title_full | Comparative Evaluation of Accuracy of Different Apex Locators: Propex IQ, Raypex 6, Root ZX, and Apex ID with CBCT and Periapical Radiograph—In Vitro Study |
title_fullStr | Comparative Evaluation of Accuracy of Different Apex Locators: Propex IQ, Raypex 6, Root ZX, and Apex ID with CBCT and Periapical Radiograph—In Vitro Study |
title_full_unstemmed | Comparative Evaluation of Accuracy of Different Apex Locators: Propex IQ, Raypex 6, Root ZX, and Apex ID with CBCT and Periapical Radiograph—In Vitro Study |
title_short | Comparative Evaluation of Accuracy of Different Apex Locators: Propex IQ, Raypex 6, Root ZX, and Apex ID with CBCT and Periapical Radiograph—In Vitro Study |
title_sort | comparative evaluation of accuracy of different apex locators: propex iq, raypex 6, root zx, and apex id with cbct and periapical radiograph—in vitro study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8112958/ https://www.ncbi.nlm.nih.gov/pubmed/34054960 http://dx.doi.org/10.1155/2021/5563426 |
work_keys_str_mv | AT mahmoudokba comparativeevaluationofaccuracyofdifferentapexlocatorspropexiqraypex6rootzxandapexidwithcbctandperiapicalradiographinvitrostudy AT awadabdelmagiedmawadahassan comparativeevaluationofaccuracyofdifferentapexlocatorspropexiqraypex6rootzxandapexidwithcbctandperiapicalradiographinvitrostudy AT dandashiahmadhisham comparativeevaluationofaccuracyofdifferentapexlocatorspropexiqraypex6rootzxandapexidwithcbctandperiapicalradiographinvitrostudy AT jasimbakrnssaief comparativeevaluationofaccuracyofdifferentapexlocatorspropexiqraypex6rootzxandapexidwithcbctandperiapicalradiographinvitrostudy AT tawfikkayalihussamalddin comparativeevaluationofaccuracyofdifferentapexlocatorspropexiqraypex6rootzxandapexidwithcbctandperiapicalradiographinvitrostudy AT alshehadatsaaid comparativeevaluationofaccuracyofdifferentapexlocatorspropexiqraypex6rootzxandapexidwithcbctandperiapicalradiographinvitrostudy |