Comparative Evaluation of Accuracy of Different Apex Locators: Propex IQ, Raypex 6, Root ZX, and Apex ID with CBCT and Periapical Radiograph—In Vitro Study

OBJECTIVES: This study aimed to validate the accuracy of working length (WL) measurements obtained with the newly introduced Propex IQ apex locator and to compare it with the latest generations of other electronic apex locators, CBCT, and conventional periapical radiographs by using the actual WL me...

Descripción completa

Detalles Bibliográficos
Autores principales: Mahmoud, Okba, Awad Abdelmagied, Mawada Hassan, Dandashi, Ahmad Hisham, Jasim, Bakr Nssaief, Tawfik Kayali, Hussam Alddin, Al Shehadat, Saaid
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8112958/
https://www.ncbi.nlm.nih.gov/pubmed/34054960
http://dx.doi.org/10.1155/2021/5563426
_version_ 1783690773050425344
author Mahmoud, Okba
Awad Abdelmagied, Mawada Hassan
Dandashi, Ahmad Hisham
Jasim, Bakr Nssaief
Tawfik Kayali, Hussam Alddin
Al Shehadat, Saaid
author_facet Mahmoud, Okba
Awad Abdelmagied, Mawada Hassan
Dandashi, Ahmad Hisham
Jasim, Bakr Nssaief
Tawfik Kayali, Hussam Alddin
Al Shehadat, Saaid
author_sort Mahmoud, Okba
collection PubMed
description OBJECTIVES: This study aimed to validate the accuracy of working length (WL) measurements obtained with the newly introduced Propex IQ apex locator and to compare it with the latest generations of other electronic apex locators, CBCT, and conventional periapical radiographs by using the actual WL measurements obtained by using an endodontics microscope as a reference. MATERIALS AND METHODS: Thirty-five extracted single-rooted human mandibular first premolars with curvatures from 10° to 20° were selected according to the inclusion and exclusion criteria and cut at the cementoenamel junction to achieve a standard reference point for WL determination. The actual WL was obtained by inserting a size-15 k-file in the root canal until the tip of the file was visible under an endodontic microscope. The definitive WL was measured using Propex IQ (Dentsply Sirona), Raypex 6 (VDW Dental), Root ZX (Morita), and Apex ID (Kerr Dental). In addition, radiographic WL was obtained using periapical radiographs and CBCT. One-way ANOVA was used for comparisons of the WL values, with a p value < 0.05. The percentage of success of each method for determination of the definitive WL was assessed using cross-tabulation and chi-square tests. RESULTS: CBCT radiographs and Propex IQ apex locator yielded the most accurate WL measurements in comparison with the actual WL measurements (p < 0.05). Raypex 6, Root ZX, and Apex ID yielded more accurate WL measurements than conventional periapical radiographs (p < 0.05). Periapical radiographs yielded the least accurate WL measurements in comparison with the actual WL values (p < 0.05). CONCLUSIONS: Within the limitations of this study, the Propex IQ apex locator showed higher accuracy than Raypex 6, Root ZX, and Apex ID for WL determination in the root canal. Nevertheless, CBCT radiographs yielded the maximum accuracy for WL measurements.
format Online
Article
Text
id pubmed-8112958
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-81129582021-05-27 Comparative Evaluation of Accuracy of Different Apex Locators: Propex IQ, Raypex 6, Root ZX, and Apex ID with CBCT and Periapical Radiograph—In Vitro Study Mahmoud, Okba Awad Abdelmagied, Mawada Hassan Dandashi, Ahmad Hisham Jasim, Bakr Nssaief Tawfik Kayali, Hussam Alddin Al Shehadat, Saaid Int J Dent Research Article OBJECTIVES: This study aimed to validate the accuracy of working length (WL) measurements obtained with the newly introduced Propex IQ apex locator and to compare it with the latest generations of other electronic apex locators, CBCT, and conventional periapical radiographs by using the actual WL measurements obtained by using an endodontics microscope as a reference. MATERIALS AND METHODS: Thirty-five extracted single-rooted human mandibular first premolars with curvatures from 10° to 20° were selected according to the inclusion and exclusion criteria and cut at the cementoenamel junction to achieve a standard reference point for WL determination. The actual WL was obtained by inserting a size-15 k-file in the root canal until the tip of the file was visible under an endodontic microscope. The definitive WL was measured using Propex IQ (Dentsply Sirona), Raypex 6 (VDW Dental), Root ZX (Morita), and Apex ID (Kerr Dental). In addition, radiographic WL was obtained using periapical radiographs and CBCT. One-way ANOVA was used for comparisons of the WL values, with a p value < 0.05. The percentage of success of each method for determination of the definitive WL was assessed using cross-tabulation and chi-square tests. RESULTS: CBCT radiographs and Propex IQ apex locator yielded the most accurate WL measurements in comparison with the actual WL measurements (p < 0.05). Raypex 6, Root ZX, and Apex ID yielded more accurate WL measurements than conventional periapical radiographs (p < 0.05). Periapical radiographs yielded the least accurate WL measurements in comparison with the actual WL values (p < 0.05). CONCLUSIONS: Within the limitations of this study, the Propex IQ apex locator showed higher accuracy than Raypex 6, Root ZX, and Apex ID for WL determination in the root canal. Nevertheless, CBCT radiographs yielded the maximum accuracy for WL measurements. Hindawi 2021-05-04 /pmc/articles/PMC8112958/ /pubmed/34054960 http://dx.doi.org/10.1155/2021/5563426 Text en Copyright © 2021 Okba Mahmoud et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Mahmoud, Okba
Awad Abdelmagied, Mawada Hassan
Dandashi, Ahmad Hisham
Jasim, Bakr Nssaief
Tawfik Kayali, Hussam Alddin
Al Shehadat, Saaid
Comparative Evaluation of Accuracy of Different Apex Locators: Propex IQ, Raypex 6, Root ZX, and Apex ID with CBCT and Periapical Radiograph—In Vitro Study
title Comparative Evaluation of Accuracy of Different Apex Locators: Propex IQ, Raypex 6, Root ZX, and Apex ID with CBCT and Periapical Radiograph—In Vitro Study
title_full Comparative Evaluation of Accuracy of Different Apex Locators: Propex IQ, Raypex 6, Root ZX, and Apex ID with CBCT and Periapical Radiograph—In Vitro Study
title_fullStr Comparative Evaluation of Accuracy of Different Apex Locators: Propex IQ, Raypex 6, Root ZX, and Apex ID with CBCT and Periapical Radiograph—In Vitro Study
title_full_unstemmed Comparative Evaluation of Accuracy of Different Apex Locators: Propex IQ, Raypex 6, Root ZX, and Apex ID with CBCT and Periapical Radiograph—In Vitro Study
title_short Comparative Evaluation of Accuracy of Different Apex Locators: Propex IQ, Raypex 6, Root ZX, and Apex ID with CBCT and Periapical Radiograph—In Vitro Study
title_sort comparative evaluation of accuracy of different apex locators: propex iq, raypex 6, root zx, and apex id with cbct and periapical radiograph—in vitro study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8112958/
https://www.ncbi.nlm.nih.gov/pubmed/34054960
http://dx.doi.org/10.1155/2021/5563426
work_keys_str_mv AT mahmoudokba comparativeevaluationofaccuracyofdifferentapexlocatorspropexiqraypex6rootzxandapexidwithcbctandperiapicalradiographinvitrostudy
AT awadabdelmagiedmawadahassan comparativeevaluationofaccuracyofdifferentapexlocatorspropexiqraypex6rootzxandapexidwithcbctandperiapicalradiographinvitrostudy
AT dandashiahmadhisham comparativeevaluationofaccuracyofdifferentapexlocatorspropexiqraypex6rootzxandapexidwithcbctandperiapicalradiographinvitrostudy
AT jasimbakrnssaief comparativeevaluationofaccuracyofdifferentapexlocatorspropexiqraypex6rootzxandapexidwithcbctandperiapicalradiographinvitrostudy
AT tawfikkayalihussamalddin comparativeevaluationofaccuracyofdifferentapexlocatorspropexiqraypex6rootzxandapexidwithcbctandperiapicalradiographinvitrostudy
AT alshehadatsaaid comparativeevaluationofaccuracyofdifferentapexlocatorspropexiqraypex6rootzxandapexidwithcbctandperiapicalradiographinvitrostudy