Cargando…

A short-term evaluation of a prototype disposable Oscillating Positive Expiratory Pressure (OPEP) device in a cohort of children with cystic fibrosis

BACKGROUND: Oscillating Positive Expiratory Pressure (OPEP) devices are important adjuncts to airway clearance therapy in patients with cystic fibrosis (CF). Current devices are typically reusable and require daily, or often more frequent, cleaning to prevent risk of infection by acting as reservoir...

Descripción completa

Detalles Bibliográficos
Autores principales: O’Sullivan, Kevin J., Power, Valerie, Linnane, Barry, McGrath, Deirdre, Mulligan, Magdalena, White, Rebecca, O’Sullivan, Leonard W., Dunne, Colum P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8114193/
https://www.ncbi.nlm.nih.gov/pubmed/33980186
http://dx.doi.org/10.1186/s12890-021-01525-3
_version_ 1783691012135190528
author O’Sullivan, Kevin J.
Power, Valerie
Linnane, Barry
McGrath, Deirdre
Mulligan, Magdalena
White, Rebecca
O’Sullivan, Leonard W.
Dunne, Colum P.
author_facet O’Sullivan, Kevin J.
Power, Valerie
Linnane, Barry
McGrath, Deirdre
Mulligan, Magdalena
White, Rebecca
O’Sullivan, Leonard W.
Dunne, Colum P.
author_sort O’Sullivan, Kevin J.
collection PubMed
description BACKGROUND: Oscillating Positive Expiratory Pressure (OPEP) devices are important adjuncts to airway clearance therapy in patients with cystic fibrosis (CF). Current devices are typically reusable and require daily, or often more frequent, cleaning to prevent risk of infection by acting as reservoirs of potentially pathogenic organisms. In response, a daily disposable OPEP device, the UL-OPEP, was developed to mitigate the risk of contamination and eliminate the burdensome need for cleaning devices. METHODS: A convenience sample of 36 participants, all current OPEP device users, was recruited from a paediatric CF service. For one month, participants replaced their current OPEP device with a novel daily disposable device. Assessment included pre- and post-intervention lung function by spirometry, as well as Lung Clearance Index. Quality of life was assessed using the Cystic Fibrosis Questionnaire – Revised, while user experience was evaluated with a post-study survey. RESULTS: 31 participants completed the study: 18 males; median age 10 years, range 4–16 years. Lung function (mean difference ± SD, %FEV1 = 1.69 ± 11.93; %FVC = 0.58 ± 10.04; FEV1: FVC = 0.01 ± 0.09), LCI (mean difference ± SD, 0.08 ± 1.13), six-minute walk test, and CFQ-R were unchanged post-intervention. Participant-reported experiences of the device were predominantly positive. CONCLUSIONS: The disposable OPEP device maintained patients’ lung function during short term use (≤ 1 month), and was the subject of positive feedback regarding functionality while reducing the risk of airway contamination associated with ineffective cleaning. REGISTRATION: The study was approved as a Clinical Investigation by the Irish Health Products Regulatory Authority (CRN-2209025-CI0085). SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12890-021-01525-3.
format Online
Article
Text
id pubmed-8114193
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-81141932021-05-12 A short-term evaluation of a prototype disposable Oscillating Positive Expiratory Pressure (OPEP) device in a cohort of children with cystic fibrosis O’Sullivan, Kevin J. Power, Valerie Linnane, Barry McGrath, Deirdre Mulligan, Magdalena White, Rebecca O’Sullivan, Leonard W. Dunne, Colum P. BMC Pulm Med Research BACKGROUND: Oscillating Positive Expiratory Pressure (OPEP) devices are important adjuncts to airway clearance therapy in patients with cystic fibrosis (CF). Current devices are typically reusable and require daily, or often more frequent, cleaning to prevent risk of infection by acting as reservoirs of potentially pathogenic organisms. In response, a daily disposable OPEP device, the UL-OPEP, was developed to mitigate the risk of contamination and eliminate the burdensome need for cleaning devices. METHODS: A convenience sample of 36 participants, all current OPEP device users, was recruited from a paediatric CF service. For one month, participants replaced their current OPEP device with a novel daily disposable device. Assessment included pre- and post-intervention lung function by spirometry, as well as Lung Clearance Index. Quality of life was assessed using the Cystic Fibrosis Questionnaire – Revised, while user experience was evaluated with a post-study survey. RESULTS: 31 participants completed the study: 18 males; median age 10 years, range 4–16 years. Lung function (mean difference ± SD, %FEV1 = 1.69 ± 11.93; %FVC = 0.58 ± 10.04; FEV1: FVC = 0.01 ± 0.09), LCI (mean difference ± SD, 0.08 ± 1.13), six-minute walk test, and CFQ-R were unchanged post-intervention. Participant-reported experiences of the device were predominantly positive. CONCLUSIONS: The disposable OPEP device maintained patients’ lung function during short term use (≤ 1 month), and was the subject of positive feedback regarding functionality while reducing the risk of airway contamination associated with ineffective cleaning. REGISTRATION: The study was approved as a Clinical Investigation by the Irish Health Products Regulatory Authority (CRN-2209025-CI0085). SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12890-021-01525-3. BioMed Central 2021-05-12 /pmc/articles/PMC8114193/ /pubmed/33980186 http://dx.doi.org/10.1186/s12890-021-01525-3 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
O’Sullivan, Kevin J.
Power, Valerie
Linnane, Barry
McGrath, Deirdre
Mulligan, Magdalena
White, Rebecca
O’Sullivan, Leonard W.
Dunne, Colum P.
A short-term evaluation of a prototype disposable Oscillating Positive Expiratory Pressure (OPEP) device in a cohort of children with cystic fibrosis
title A short-term evaluation of a prototype disposable Oscillating Positive Expiratory Pressure (OPEP) device in a cohort of children with cystic fibrosis
title_full A short-term evaluation of a prototype disposable Oscillating Positive Expiratory Pressure (OPEP) device in a cohort of children with cystic fibrosis
title_fullStr A short-term evaluation of a prototype disposable Oscillating Positive Expiratory Pressure (OPEP) device in a cohort of children with cystic fibrosis
title_full_unstemmed A short-term evaluation of a prototype disposable Oscillating Positive Expiratory Pressure (OPEP) device in a cohort of children with cystic fibrosis
title_short A short-term evaluation of a prototype disposable Oscillating Positive Expiratory Pressure (OPEP) device in a cohort of children with cystic fibrosis
title_sort short-term evaluation of a prototype disposable oscillating positive expiratory pressure (opep) device in a cohort of children with cystic fibrosis
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8114193/
https://www.ncbi.nlm.nih.gov/pubmed/33980186
http://dx.doi.org/10.1186/s12890-021-01525-3
work_keys_str_mv AT osullivankevinj ashorttermevaluationofaprototypedisposableoscillatingpositiveexpiratorypressureopepdeviceinacohortofchildrenwithcysticfibrosis
AT powervalerie ashorttermevaluationofaprototypedisposableoscillatingpositiveexpiratorypressureopepdeviceinacohortofchildrenwithcysticfibrosis
AT linnanebarry ashorttermevaluationofaprototypedisposableoscillatingpositiveexpiratorypressureopepdeviceinacohortofchildrenwithcysticfibrosis
AT mcgrathdeirdre ashorttermevaluationofaprototypedisposableoscillatingpositiveexpiratorypressureopepdeviceinacohortofchildrenwithcysticfibrosis
AT mulliganmagdalena ashorttermevaluationofaprototypedisposableoscillatingpositiveexpiratorypressureopepdeviceinacohortofchildrenwithcysticfibrosis
AT whiterebecca ashorttermevaluationofaprototypedisposableoscillatingpositiveexpiratorypressureopepdeviceinacohortofchildrenwithcysticfibrosis
AT osullivanleonardw ashorttermevaluationofaprototypedisposableoscillatingpositiveexpiratorypressureopepdeviceinacohortofchildrenwithcysticfibrosis
AT dunnecolump ashorttermevaluationofaprototypedisposableoscillatingpositiveexpiratorypressureopepdeviceinacohortofchildrenwithcysticfibrosis
AT osullivankevinj shorttermevaluationofaprototypedisposableoscillatingpositiveexpiratorypressureopepdeviceinacohortofchildrenwithcysticfibrosis
AT powervalerie shorttermevaluationofaprototypedisposableoscillatingpositiveexpiratorypressureopepdeviceinacohortofchildrenwithcysticfibrosis
AT linnanebarry shorttermevaluationofaprototypedisposableoscillatingpositiveexpiratorypressureopepdeviceinacohortofchildrenwithcysticfibrosis
AT mcgrathdeirdre shorttermevaluationofaprototypedisposableoscillatingpositiveexpiratorypressureopepdeviceinacohortofchildrenwithcysticfibrosis
AT mulliganmagdalena shorttermevaluationofaprototypedisposableoscillatingpositiveexpiratorypressureopepdeviceinacohortofchildrenwithcysticfibrosis
AT whiterebecca shorttermevaluationofaprototypedisposableoscillatingpositiveexpiratorypressureopepdeviceinacohortofchildrenwithcysticfibrosis
AT osullivanleonardw shorttermevaluationofaprototypedisposableoscillatingpositiveexpiratorypressureopepdeviceinacohortofchildrenwithcysticfibrosis
AT dunnecolump shorttermevaluationofaprototypedisposableoscillatingpositiveexpiratorypressureopepdeviceinacohortofchildrenwithcysticfibrosis