Cargando…
Antibiotic Prophylaxis and Treatment in Early Cardiac Implantable Electronic Devices Infection
BACKGROUND: Cardiac implantable electronic devices – PM, ICD, and CRTs- are well-proven life-sustaining and the ultimate destination for many heart conditions. Based on scientific evidence, there is a worldwide incremental increase in CIED implantations numbers. OBJECTIVE: Early infection of cardiac...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Academy of Medical Sciences of Bosnia and Herzegovina
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8116075/ https://www.ncbi.nlm.nih.gov/pubmed/34012201 http://dx.doi.org/10.5455/medarh.2021.75.56-60 |
Sumario: | BACKGROUND: Cardiac implantable electronic devices – PM, ICD, and CRTs- are well-proven life-sustaining and the ultimate destination for many heart conditions. Based on scientific evidence, there is a worldwide incremental increase in CIED implantations numbers. OBJECTIVE: Early infection of cardiac implantable electronic devices (CIED)– pacemaker (PM), implantable cardioverter-defibrillator (ICD), and cardiac resynchronization therapy (CRT)– is a growing health challenge. We examined the effectiveness of antibiotic prophylaxis and treatment of early infection of CIED in a single center. METHODS: This is a retrospective, single-center observational study. Data were collected from patients’ records from July 2017-July, 2019. All Patients received intravenous ceftriaxone 2gm before incision, Gentamicin 120mg pocket irrigation, and oral Amoxicillin/Clavulanate for 5 days post-implantation. RESULTS: A 639 consecutive CIED implantations – PM (n=474, mean age, 64yr, female=49%), ICD (n=106, mean age 56yr, female=17%) and CRT (n=59, mean age, 54yr, female=20%)- were performed over 3years. The incidence of early infection was 1.9% (12 cases), female=41%. PM=5/474, ICD=5/106, and CRT=2/59. Three out of the 12 patients had total device explant due to pocket abscess; one PM had a generator changed; one ICD who had a pneumothorax, and the third one had reimplantation after ICD lead perforation. Nine cases were managed conservatively using saline dressing and oral Amoxicillin/Clavulanate, 3/9 patients developed a hematoma, 4/9 patients developed purulent suture line infection. None of them had infection recurrence on three months follow up. CONCLUSION: Early infection of CIED is a rare complication with multiple predisposing factors. Our protocol is reassurance and prompt initiation of management protocol to prevent and treat this issue’s sequences. |
---|