Hybrid Closed-Loop System Achieves Optimal Perioperative Glycemia in a Boy With Type 1 Diabetes: A Case Report

The goal in type 1 diabetes (T1D) therapy is to maintain optimal glycemic control under any circumstance. Diabetes technology is in continuous development to achieve this goal. The most advanced Food and Drug Administration- and European Medicines Agency-approved devices are hybrid closed-loop (HCL)...

Descripción completa

Detalles Bibliográficos
Autores principales: Dominguez-Riscart, Jesus, Buero-Fernandez, Nuria, Garcia-Zarzuela, Ana, Marmolejo-Franco, Fernando A., Perez-Guerrero, Ana C., Lechuga-Sancho, Alfonso M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8116592/
https://www.ncbi.nlm.nih.gov/pubmed/33996680
http://dx.doi.org/10.3389/fped.2021.625390
_version_ 1783691427189882880
author Dominguez-Riscart, Jesus
Buero-Fernandez, Nuria
Garcia-Zarzuela, Ana
Marmolejo-Franco, Fernando A.
Perez-Guerrero, Ana C.
Lechuga-Sancho, Alfonso M.
author_facet Dominguez-Riscart, Jesus
Buero-Fernandez, Nuria
Garcia-Zarzuela, Ana
Marmolejo-Franco, Fernando A.
Perez-Guerrero, Ana C.
Lechuga-Sancho, Alfonso M.
author_sort Dominguez-Riscart, Jesus
collection PubMed
description The goal in type 1 diabetes (T1D) therapy is to maintain optimal glycemic control under any circumstance. Diabetes technology is in continuous development to achieve this goal. The most advanced Food and Drug Administration- and European Medicines Agency-approved devices are hybrid closed-loop (HCL) systems, which deliver insulin subcutaneously in response to glucose levels according to an automated algorithm. T1D is frequently encountered in the perioperative period. The latest international guidelines for the management of children with diabetes undergoing surgery include specific adjustments to the patient's insulin therapy, hourly blood glucose monitoring, and intravenous (IV) insulin infusion. However, these guidelines were published while the HCL systems were still marginal. We present a case of a 9-year-old boy with long-standing T1D, under HCL system therapy for the last 9 months, and needing surgery for an appendectomy. We agreed with the family, the surgical team, and the anesthesiologists to continue HCL insulin infusion, without further adjustments, hourly blood glucose checks or IV insulin, while monitoring closely. The HCL system was able to keep glycemia within range for the total duration of the overnight fast, the surgery, and the initial recovery, without any external intervention or correction bolus. This is, to the best of our knowledge, the first reported pediatric case to undergo major surgery using a HCL system, and the results were absolutely satisfactory for the patient, his family, and the medical team. We believe that technology is ripe enough to advocate for a “take your pump to surgery” message, minimizing the impact and our interventions. The medical team may discuss this possibility with the family and patients.
format Online
Article
Text
id pubmed-8116592
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-81165922021-05-14 Hybrid Closed-Loop System Achieves Optimal Perioperative Glycemia in a Boy With Type 1 Diabetes: A Case Report Dominguez-Riscart, Jesus Buero-Fernandez, Nuria Garcia-Zarzuela, Ana Marmolejo-Franco, Fernando A. Perez-Guerrero, Ana C. Lechuga-Sancho, Alfonso M. Front Pediatr Pediatrics The goal in type 1 diabetes (T1D) therapy is to maintain optimal glycemic control under any circumstance. Diabetes technology is in continuous development to achieve this goal. The most advanced Food and Drug Administration- and European Medicines Agency-approved devices are hybrid closed-loop (HCL) systems, which deliver insulin subcutaneously in response to glucose levels according to an automated algorithm. T1D is frequently encountered in the perioperative period. The latest international guidelines for the management of children with diabetes undergoing surgery include specific adjustments to the patient's insulin therapy, hourly blood glucose monitoring, and intravenous (IV) insulin infusion. However, these guidelines were published while the HCL systems were still marginal. We present a case of a 9-year-old boy with long-standing T1D, under HCL system therapy for the last 9 months, and needing surgery for an appendectomy. We agreed with the family, the surgical team, and the anesthesiologists to continue HCL insulin infusion, without further adjustments, hourly blood glucose checks or IV insulin, while monitoring closely. The HCL system was able to keep glycemia within range for the total duration of the overnight fast, the surgery, and the initial recovery, without any external intervention or correction bolus. This is, to the best of our knowledge, the first reported pediatric case to undergo major surgery using a HCL system, and the results were absolutely satisfactory for the patient, his family, and the medical team. We believe that technology is ripe enough to advocate for a “take your pump to surgery” message, minimizing the impact and our interventions. The medical team may discuss this possibility with the family and patients. Frontiers Media S.A. 2021-04-29 /pmc/articles/PMC8116592/ /pubmed/33996680 http://dx.doi.org/10.3389/fped.2021.625390 Text en Copyright © 2021 Dominguez-Riscart, Buero-Fernandez, Garcia-Zarzuela, Marmolejo-Franco, Perez-Guerrero and Lechuga-Sancho. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Pediatrics
Dominguez-Riscart, Jesus
Buero-Fernandez, Nuria
Garcia-Zarzuela, Ana
Marmolejo-Franco, Fernando A.
Perez-Guerrero, Ana C.
Lechuga-Sancho, Alfonso M.
Hybrid Closed-Loop System Achieves Optimal Perioperative Glycemia in a Boy With Type 1 Diabetes: A Case Report
title Hybrid Closed-Loop System Achieves Optimal Perioperative Glycemia in a Boy With Type 1 Diabetes: A Case Report
title_full Hybrid Closed-Loop System Achieves Optimal Perioperative Glycemia in a Boy With Type 1 Diabetes: A Case Report
title_fullStr Hybrid Closed-Loop System Achieves Optimal Perioperative Glycemia in a Boy With Type 1 Diabetes: A Case Report
title_full_unstemmed Hybrid Closed-Loop System Achieves Optimal Perioperative Glycemia in a Boy With Type 1 Diabetes: A Case Report
title_short Hybrid Closed-Loop System Achieves Optimal Perioperative Glycemia in a Boy With Type 1 Diabetes: A Case Report
title_sort hybrid closed-loop system achieves optimal perioperative glycemia in a boy with type 1 diabetes: a case report
topic Pediatrics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8116592/
https://www.ncbi.nlm.nih.gov/pubmed/33996680
http://dx.doi.org/10.3389/fped.2021.625390
work_keys_str_mv AT dominguezriscartjesus hybridclosedloopsystemachievesoptimalperioperativeglycemiainaboywithtype1diabetesacasereport
AT buerofernandeznuria hybridclosedloopsystemachievesoptimalperioperativeglycemiainaboywithtype1diabetesacasereport
AT garciazarzuelaana hybridclosedloopsystemachievesoptimalperioperativeglycemiainaboywithtype1diabetesacasereport
AT marmolejofrancofernandoa hybridclosedloopsystemachievesoptimalperioperativeglycemiainaboywithtype1diabetesacasereport
AT perezguerreroanac hybridclosedloopsystemachievesoptimalperioperativeglycemiainaboywithtype1diabetesacasereport
AT lechugasanchoalfonsom hybridclosedloopsystemachievesoptimalperioperativeglycemiainaboywithtype1diabetesacasereport