Cargando…

More in, better out? Successful valve-in-valve procedure of an iatrogenic ventricular septal defect following transcatheter aortic valve replacement: a case report

BACKGROUND: A rare, but serious, complication following transcatheter aortic valve replacement (TAVR) is the occurrence of an iatrogenic ventricular septal defect (VSD). CASE SUMMARY: We describe a case of an 80-year-old female who was referred with severe aortic stenosis for TAVR. Following thoroug...

Descripción completa

Detalles Bibliográficos
Autores principales: Hönemann, Klaus-Dieter, Hofmann, Steffen, Ritter, Frank, Mönnig, Gerold
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8117460/
https://www.ncbi.nlm.nih.gov/pubmed/34013160
http://dx.doi.org/10.1093/ehjcr/ytab097
_version_ 1783691589981306880
author Hönemann, Klaus-Dieter
Hofmann, Steffen
Ritter, Frank
Mönnig, Gerold
author_facet Hönemann, Klaus-Dieter
Hofmann, Steffen
Ritter, Frank
Mönnig, Gerold
author_sort Hönemann, Klaus-Dieter
collection PubMed
description BACKGROUND: A rare, but serious, complication following transcatheter aortic valve replacement (TAVR) is the occurrence of an iatrogenic ventricular septal defect (VSD). CASE SUMMARY: We describe a case of an 80-year-old female who was referred with severe aortic stenosis for TAVR. Following thorough evaluation, the heart team consensus was to proceed with implantation via a transapical approach of an ACURATE neo M 25 mm valve (Boston Scientific, Natick, MA, USA). The valve was deployed harnessing transoesophageal echocardiographic (TOE) guidance under rapid pacing with post-dilation. Directly afterwards a very high VSD close to the aortic annulus was detected. As the patient was haemodynamically stable, the procedure was ended. The next day another TOE revealed a shunt volume (left-to-right ventricle) between 50% and 60%. Because the defect was partly located between the stent struts of the ACURATE valve decision was made to fix this leakage with implantation of a further valve and we chose an EVOLUT Pro 29 mm (Medtronic Inc., Minneapolis, MN, USA). The valve-in-valve was implanted 2–3 mm below the lower edge of the first valve, more towards the left ventricular outflow tract (LVOT) with excellent result: VSD was reduced to a very small residual shunt without any hemodynamic relevance. DISCUSSION: We suggest that an iatrogenic VSD located near the annulus may be treated percutaneously in a bail-out situation with implantation of a second valve that should be implanted slightly more into the LVOT to cover the VSD.
format Online
Article
Text
id pubmed-8117460
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-81174602021-05-18 More in, better out? Successful valve-in-valve procedure of an iatrogenic ventricular septal defect following transcatheter aortic valve replacement: a case report Hönemann, Klaus-Dieter Hofmann, Steffen Ritter, Frank Mönnig, Gerold Eur Heart J Case Rep Case Report BACKGROUND: A rare, but serious, complication following transcatheter aortic valve replacement (TAVR) is the occurrence of an iatrogenic ventricular septal defect (VSD). CASE SUMMARY: We describe a case of an 80-year-old female who was referred with severe aortic stenosis for TAVR. Following thorough evaluation, the heart team consensus was to proceed with implantation via a transapical approach of an ACURATE neo M 25 mm valve (Boston Scientific, Natick, MA, USA). The valve was deployed harnessing transoesophageal echocardiographic (TOE) guidance under rapid pacing with post-dilation. Directly afterwards a very high VSD close to the aortic annulus was detected. As the patient was haemodynamically stable, the procedure was ended. The next day another TOE revealed a shunt volume (left-to-right ventricle) between 50% and 60%. Because the defect was partly located between the stent struts of the ACURATE valve decision was made to fix this leakage with implantation of a further valve and we chose an EVOLUT Pro 29 mm (Medtronic Inc., Minneapolis, MN, USA). The valve-in-valve was implanted 2–3 mm below the lower edge of the first valve, more towards the left ventricular outflow tract (LVOT) with excellent result: VSD was reduced to a very small residual shunt without any hemodynamic relevance. DISCUSSION: We suggest that an iatrogenic VSD located near the annulus may be treated percutaneously in a bail-out situation with implantation of a second valve that should be implanted slightly more into the LVOT to cover the VSD. Oxford University Press 2021-05-12 /pmc/articles/PMC8117460/ /pubmed/34013160 http://dx.doi.org/10.1093/ehjcr/ytab097 Text en © The Author(s) 2021. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Case Report
Hönemann, Klaus-Dieter
Hofmann, Steffen
Ritter, Frank
Mönnig, Gerold
More in, better out? Successful valve-in-valve procedure of an iatrogenic ventricular septal defect following transcatheter aortic valve replacement: a case report
title More in, better out? Successful valve-in-valve procedure of an iatrogenic ventricular septal defect following transcatheter aortic valve replacement: a case report
title_full More in, better out? Successful valve-in-valve procedure of an iatrogenic ventricular septal defect following transcatheter aortic valve replacement: a case report
title_fullStr More in, better out? Successful valve-in-valve procedure of an iatrogenic ventricular septal defect following transcatheter aortic valve replacement: a case report
title_full_unstemmed More in, better out? Successful valve-in-valve procedure of an iatrogenic ventricular septal defect following transcatheter aortic valve replacement: a case report
title_short More in, better out? Successful valve-in-valve procedure of an iatrogenic ventricular septal defect following transcatheter aortic valve replacement: a case report
title_sort more in, better out? successful valve-in-valve procedure of an iatrogenic ventricular septal defect following transcatheter aortic valve replacement: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8117460/
https://www.ncbi.nlm.nih.gov/pubmed/34013160
http://dx.doi.org/10.1093/ehjcr/ytab097
work_keys_str_mv AT honemannklausdieter moreinbetteroutsuccessfulvalveinvalveprocedureofaniatrogenicventricularseptaldefectfollowingtranscatheteraorticvalvereplacementacasereport
AT hofmannsteffen moreinbetteroutsuccessfulvalveinvalveprocedureofaniatrogenicventricularseptaldefectfollowingtranscatheteraorticvalvereplacementacasereport
AT ritterfrank moreinbetteroutsuccessfulvalveinvalveprocedureofaniatrogenicventricularseptaldefectfollowingtranscatheteraorticvalvereplacementacasereport
AT monniggerold moreinbetteroutsuccessfulvalveinvalveprocedureofaniatrogenicventricularseptaldefectfollowingtranscatheteraorticvalvereplacementacasereport