Cargando…
The Changes in Cervical Biomechanics After CTDR and Its Association With Heterotopic Ossification: A Systematic Review and Meta-analysis
STUDY DESIGN: A systematic review and meta-analysis. OBJECTIVES: Cervical total disc replacement (CTDR) can preserve range of motion (ROM) of the operated spinal segment in cadaver studies. Evidence is less clear in clinical trials. The present study aims to investigate the differences in cervical b...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8119929/ https://www.ncbi.nlm.nih.gov/pubmed/32677512 http://dx.doi.org/10.1177/2192568220922949 |
_version_ | 1783691959482712064 |
---|---|
author | Hui, Nicholas Phan, Kevin Lee, Mei-Yi Kerferd, Jack Singh, Telvinderjit Mobbs, Ralph J. |
author_facet | Hui, Nicholas Phan, Kevin Lee, Mei-Yi Kerferd, Jack Singh, Telvinderjit Mobbs, Ralph J. |
author_sort | Hui, Nicholas |
collection | PubMed |
description | STUDY DESIGN: A systematic review and meta-analysis. OBJECTIVES: Cervical total disc replacement (CTDR) can preserve range of motion (ROM) of the operated spinal segment in cadaver studies. Evidence is less clear in clinical trials. The present study aims to investigate the differences in cervical biomechanics before and after CTDR and its association with heterotopic ossification (HO) development. METHOD: Articles that reported the rate of HO and ≥1 difference in cervical biomechanics were included in quantitative analyses. We pooled the mean difference (MD) of cervical biomechanics before and after CTDR. Subgroup analyses and metaregression analyses were conducted to identify potential contributors to heterogeneity. RESULTS: Of the 599 studies screened, 35 studies were included in the final analysis. In comparison with preoperative values, ROM of the spinal segment inferior (MD: 0.38; 95% CI: 0.02 to 0.74) and superior (MD: 0.43; 95% CI: 0.12 to 0.75) to the surgical spinal segment, functional spinal unit (FSU) angle (MD: 2.23; 95% CI: 1.11 to 3.35), and C2/C7 Cobb angle (MD: 3.49; 95% CI: 1.73 to 5.25) significantly increased after CTDR. In contrast, FSU and cervical ROM at baseline were no different from follow-up. On multivariable meta-regression analyses, HO and ROM-limiting HO were not associated with changes in cervical biomechanics. Single-level CTDR and duration of follow-up were associated with changes in cervical biomechanics. CONCLUSION: Our study reported the pooled mean of biomechanics at baseline and final follow-up and their differences. The changes in biomechanics were not associated with the rates of HO and ROM-limiting HO. |
format | Online Article Text |
id | pubmed-8119929 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-81199292021-05-21 The Changes in Cervical Biomechanics After CTDR and Its Association With Heterotopic Ossification: A Systematic Review and Meta-analysis Hui, Nicholas Phan, Kevin Lee, Mei-Yi Kerferd, Jack Singh, Telvinderjit Mobbs, Ralph J. Global Spine J Review Articles STUDY DESIGN: A systematic review and meta-analysis. OBJECTIVES: Cervical total disc replacement (CTDR) can preserve range of motion (ROM) of the operated spinal segment in cadaver studies. Evidence is less clear in clinical trials. The present study aims to investigate the differences in cervical biomechanics before and after CTDR and its association with heterotopic ossification (HO) development. METHOD: Articles that reported the rate of HO and ≥1 difference in cervical biomechanics were included in quantitative analyses. We pooled the mean difference (MD) of cervical biomechanics before and after CTDR. Subgroup analyses and metaregression analyses were conducted to identify potential contributors to heterogeneity. RESULTS: Of the 599 studies screened, 35 studies were included in the final analysis. In comparison with preoperative values, ROM of the spinal segment inferior (MD: 0.38; 95% CI: 0.02 to 0.74) and superior (MD: 0.43; 95% CI: 0.12 to 0.75) to the surgical spinal segment, functional spinal unit (FSU) angle (MD: 2.23; 95% CI: 1.11 to 3.35), and C2/C7 Cobb angle (MD: 3.49; 95% CI: 1.73 to 5.25) significantly increased after CTDR. In contrast, FSU and cervical ROM at baseline were no different from follow-up. On multivariable meta-regression analyses, HO and ROM-limiting HO were not associated with changes in cervical biomechanics. Single-level CTDR and duration of follow-up were associated with changes in cervical biomechanics. CONCLUSION: Our study reported the pooled mean of biomechanics at baseline and final follow-up and their differences. The changes in biomechanics were not associated with the rates of HO and ROM-limiting HO. SAGE Publications 2020-06-03 2021-05 /pmc/articles/PMC8119929/ /pubmed/32677512 http://dx.doi.org/10.1177/2192568220922949 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by-nc-nd/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 License (https://creativecommons.org/licenses/by-nc-nd/4.0/) which permits non-commercial use, reproduction and distribution of the work as published without adaptation or alteration, without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Review Articles Hui, Nicholas Phan, Kevin Lee, Mei-Yi Kerferd, Jack Singh, Telvinderjit Mobbs, Ralph J. The Changes in Cervical Biomechanics After CTDR and Its Association With Heterotopic Ossification: A Systematic Review and Meta-analysis |
title | The Changes in Cervical Biomechanics After CTDR and Its Association
With Heterotopic Ossification: A Systematic Review and
Meta-analysis |
title_full | The Changes in Cervical Biomechanics After CTDR and Its Association
With Heterotopic Ossification: A Systematic Review and
Meta-analysis |
title_fullStr | The Changes in Cervical Biomechanics After CTDR and Its Association
With Heterotopic Ossification: A Systematic Review and
Meta-analysis |
title_full_unstemmed | The Changes in Cervical Biomechanics After CTDR and Its Association
With Heterotopic Ossification: A Systematic Review and
Meta-analysis |
title_short | The Changes in Cervical Biomechanics After CTDR and Its Association
With Heterotopic Ossification: A Systematic Review and
Meta-analysis |
title_sort | changes in cervical biomechanics after ctdr and its association
with heterotopic ossification: a systematic review and
meta-analysis |
topic | Review Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8119929/ https://www.ncbi.nlm.nih.gov/pubmed/32677512 http://dx.doi.org/10.1177/2192568220922949 |
work_keys_str_mv | AT huinicholas thechangesincervicalbiomechanicsafterctdranditsassociationwithheterotopicossificationasystematicreviewandmetaanalysis AT phankevin thechangesincervicalbiomechanicsafterctdranditsassociationwithheterotopicossificationasystematicreviewandmetaanalysis AT leemeiyi thechangesincervicalbiomechanicsafterctdranditsassociationwithheterotopicossificationasystematicreviewandmetaanalysis AT kerferdjack thechangesincervicalbiomechanicsafterctdranditsassociationwithheterotopicossificationasystematicreviewandmetaanalysis AT singhtelvinderjit thechangesincervicalbiomechanicsafterctdranditsassociationwithheterotopicossificationasystematicreviewandmetaanalysis AT mobbsralphj thechangesincervicalbiomechanicsafterctdranditsassociationwithheterotopicossificationasystematicreviewandmetaanalysis AT huinicholas changesincervicalbiomechanicsafterctdranditsassociationwithheterotopicossificationasystematicreviewandmetaanalysis AT phankevin changesincervicalbiomechanicsafterctdranditsassociationwithheterotopicossificationasystematicreviewandmetaanalysis AT leemeiyi changesincervicalbiomechanicsafterctdranditsassociationwithheterotopicossificationasystematicreviewandmetaanalysis AT kerferdjack changesincervicalbiomechanicsafterctdranditsassociationwithheterotopicossificationasystematicreviewandmetaanalysis AT singhtelvinderjit changesincervicalbiomechanicsafterctdranditsassociationwithheterotopicossificationasystematicreviewandmetaanalysis AT mobbsralphj changesincervicalbiomechanicsafterctdranditsassociationwithheterotopicossificationasystematicreviewandmetaanalysis |