Cargando…

A Systematic Review and Meta-analysis of Randomized Controlled Trials Comparing the Accuracy and Clinical Outcome of Pedicle Screw Placement Using Robot-Assisted Technology and Conventional Freehand Technique

STUDY DESIGN: Systematic review and meta-analysis of randomized controlled trials (RCTs). OBJECTIVE: This systematic review and meta-analysis was performed with the aim of exploring the differences in pedicle screw positioning accuracy, surgical time, length of hospital stay, postoperative back and...

Descripción completa

Detalles Bibliográficos
Autores principales: Tarawneh, Ahmad M., Salem, Khalid MI.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8119930/
https://www.ncbi.nlm.nih.gov/pubmed/32677515
http://dx.doi.org/10.1177/2192568220927713
_version_ 1783691959708155904
author Tarawneh, Ahmad M.
Salem, Khalid MI.
author_facet Tarawneh, Ahmad M.
Salem, Khalid MI.
author_sort Tarawneh, Ahmad M.
collection PubMed
description STUDY DESIGN: Systematic review and meta-analysis of randomized controlled trials (RCTs). OBJECTIVE: This systematic review and meta-analysis was performed with the aim of exploring the differences in pedicle screw positioning accuracy, surgical time, length of hospital stay, postoperative back and leg Visual Analog Scale, revision surgeries, and intraoperative radiation time and exposure between robot-assisted technology and conventional freehand technique based on RCTs. METHODS: Several databases, including the Cochrane library, PubMed, and EMBASE were systematically searched to identify potentially eligible articles. Meta-analysis was done using STATA 13 software. The odds ratios and 95% CIs were calculated for the studied categories. RESULTS: Seven RCTs involving 290 patients (1298 pedicle screws) in the robot-assisted group and 288 patients (1348 pedicle screws) in the conventional freehand group were analyzed. The results revealed that grade (A) and grade (A+B) screw accuracies were significantly superior in the robot-assisted group (P = .008 and P = .009, respectively). Overall surgical duration and number of revision surgeries were significantly higher in the robot-assisted group (P = .014 and P < .0001, respectively). Intraoperative radiation time and dosage were significantly lower in the robot-assisted group (P < .0001 and P = .036, respectively). CONCLUSION: It was demonstrated that robot-assisted technology is superior to the conventional freehand technique in terms of grade (A) and grade (A+B) screw accuracies and in the reduction of intraoperative radiation time and dosage. On the other hand, the freehand technique showed superior results in terms of overall surgical duration and revision surgery rates.
format Online
Article
Text
id pubmed-8119930
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-81199302021-05-21 A Systematic Review and Meta-analysis of Randomized Controlled Trials Comparing the Accuracy and Clinical Outcome of Pedicle Screw Placement Using Robot-Assisted Technology and Conventional Freehand Technique Tarawneh, Ahmad M. Salem, Khalid MI. Global Spine J Review Articles STUDY DESIGN: Systematic review and meta-analysis of randomized controlled trials (RCTs). OBJECTIVE: This systematic review and meta-analysis was performed with the aim of exploring the differences in pedicle screw positioning accuracy, surgical time, length of hospital stay, postoperative back and leg Visual Analog Scale, revision surgeries, and intraoperative radiation time and exposure between robot-assisted technology and conventional freehand technique based on RCTs. METHODS: Several databases, including the Cochrane library, PubMed, and EMBASE were systematically searched to identify potentially eligible articles. Meta-analysis was done using STATA 13 software. The odds ratios and 95% CIs were calculated for the studied categories. RESULTS: Seven RCTs involving 290 patients (1298 pedicle screws) in the robot-assisted group and 288 patients (1348 pedicle screws) in the conventional freehand group were analyzed. The results revealed that grade (A) and grade (A+B) screw accuracies were significantly superior in the robot-assisted group (P = .008 and P = .009, respectively). Overall surgical duration and number of revision surgeries were significantly higher in the robot-assisted group (P = .014 and P < .0001, respectively). Intraoperative radiation time and dosage were significantly lower in the robot-assisted group (P < .0001 and P = .036, respectively). CONCLUSION: It was demonstrated that robot-assisted technology is superior to the conventional freehand technique in terms of grade (A) and grade (A+B) screw accuracies and in the reduction of intraoperative radiation time and dosage. On the other hand, the freehand technique showed superior results in terms of overall surgical duration and revision surgery rates. SAGE Publications 2020-06-05 2021-05 /pmc/articles/PMC8119930/ /pubmed/32677515 http://dx.doi.org/10.1177/2192568220927713 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by-nc-nd/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 License (https://creativecommons.org/licenses/by-nc-nd/4.0/) which permits non-commercial use, reproduction and distribution of the work as published without adaptation or alteration, without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Review Articles
Tarawneh, Ahmad M.
Salem, Khalid MI.
A Systematic Review and Meta-analysis of Randomized Controlled Trials Comparing the Accuracy and Clinical Outcome of Pedicle Screw Placement Using Robot-Assisted Technology and Conventional Freehand Technique
title A Systematic Review and Meta-analysis of Randomized Controlled Trials Comparing the Accuracy and Clinical Outcome of Pedicle Screw Placement Using Robot-Assisted Technology and Conventional Freehand Technique
title_full A Systematic Review and Meta-analysis of Randomized Controlled Trials Comparing the Accuracy and Clinical Outcome of Pedicle Screw Placement Using Robot-Assisted Technology and Conventional Freehand Technique
title_fullStr A Systematic Review and Meta-analysis of Randomized Controlled Trials Comparing the Accuracy and Clinical Outcome of Pedicle Screw Placement Using Robot-Assisted Technology and Conventional Freehand Technique
title_full_unstemmed A Systematic Review and Meta-analysis of Randomized Controlled Trials Comparing the Accuracy and Clinical Outcome of Pedicle Screw Placement Using Robot-Assisted Technology and Conventional Freehand Technique
title_short A Systematic Review and Meta-analysis of Randomized Controlled Trials Comparing the Accuracy and Clinical Outcome of Pedicle Screw Placement Using Robot-Assisted Technology and Conventional Freehand Technique
title_sort systematic review and meta-analysis of randomized controlled trials comparing the accuracy and clinical outcome of pedicle screw placement using robot-assisted technology and conventional freehand technique
topic Review Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8119930/
https://www.ncbi.nlm.nih.gov/pubmed/32677515
http://dx.doi.org/10.1177/2192568220927713
work_keys_str_mv AT tarawnehahmadm asystematicreviewandmetaanalysisofrandomizedcontrolledtrialscomparingtheaccuracyandclinicaloutcomeofpediclescrewplacementusingrobotassistedtechnologyandconventionalfreehandtechnique
AT salemkhalidmi asystematicreviewandmetaanalysisofrandomizedcontrolledtrialscomparingtheaccuracyandclinicaloutcomeofpediclescrewplacementusingrobotassistedtechnologyandconventionalfreehandtechnique
AT tarawnehahmadm systematicreviewandmetaanalysisofrandomizedcontrolledtrialscomparingtheaccuracyandclinicaloutcomeofpediclescrewplacementusingrobotassistedtechnologyandconventionalfreehandtechnique
AT salemkhalidmi systematicreviewandmetaanalysisofrandomizedcontrolledtrialscomparingtheaccuracyandclinicaloutcomeofpediclescrewplacementusingrobotassistedtechnologyandconventionalfreehandtechnique