Cargando…

Reducing the Risk of Ring Breakage in Taylor Spatial Frames: The Effect of Frame Configuration on Strain at the Half-ring Junction

AIM: We have encountered four cases with Taylor spatial frames (TSF) (Smith & Nephew, Memphis, TN, USA) with breakage at the half-ring junction of the distal ring. This study examines the strain produced on different locations of the distal ring during loading and the effects on the strain of al...

Descripción completa

Detalles Bibliográficos
Autores principales: Iliadis, Alexios D, Bebja, Roland, Wang, Katherine, Moazen, Mehran, Wright, Jonathan, Calder, Peter, Goodier, David
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Jaypee Brothers Medical Publishing 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8121110/
https://www.ncbi.nlm.nih.gov/pubmed/34025794
http://dx.doi.org/10.5005/jp-journals-10080-1508
_version_ 1783692260058071040
author Iliadis, Alexios D
Bebja, Roland
Wang, Katherine
Moazen, Mehran
Wright, Jonathan
Calder, Peter
Goodier, David
author_facet Iliadis, Alexios D
Bebja, Roland
Wang, Katherine
Moazen, Mehran
Wright, Jonathan
Calder, Peter
Goodier, David
author_sort Iliadis, Alexios D
collection PubMed
description AIM: We have encountered four cases with Taylor spatial frames (TSF) (Smith & Nephew, Memphis, TN, USA) with breakage at the half-ring junction of the distal ring. This study examines the strain produced on different locations of the distal ring during loading and the effects on the strain of altering the frame construct. MATERIALS AND METHODS: We mounted two ring TSF constructs on tibia saw bone models. The proximal ring was the same in all constructs and consisted of a 2/3 180 mm ring attached with three wires. Construct 1 is reproducing the configuration of cases where failure was seen. The distal 155 mm ring is attached with three half pins. The half-ring junction is located in the midline. Construct 2 has a different half pin placement and an additional wire on the distal ring. Constructs 3 and 4 have the same half pin configuration to construct 1 but the distal ring is rotated 60° internally and externally, respectively. Strain gauges were attached to different locations and measurements recorded during loading. Statistical analysis was performed. RESULTS: Highest strain values were recorded at the half-ring junction of constructs 1 and 2 (>600 microstrains (με) in tension). Rotating the ring 60° internally significantly reduces the strain at the half-ring junction (<300 με) whilst external rotation by 60° further reduces the strain (<180 με). Ring strain is higher in areas close to half pin attachments. CONCLUSION: The highest strain is in the half-ring junction as the half rings are subjected to different loading modes. The thickness of the half-ring is halved and the second moment of area reduced further increasing breakage risk. Placing this junction close to the half pin–frame interface, as dictated by the anatomical safe zone further increases the strain. Rotating the distal ring 60° significantly reduces the strain at the half-ring junction. CLINICAL SIGNIFICANCE: Ring breakage is a rare but significant complication. This is the first study to address this potential mode of TSF failure. Insights and technical tips from this study can help reduce this. HOW TO CITE THIS ARTICLE: Iliadis AD, Bebja R, Wang K, et al. Reducing the Risk of Ring Breakage in Taylor Spatial Frames: The Effect of Frame Configuration on Strain at the Half-ring Junction. Strategies Trauma Limb Reconstr 2020;15(3):146–150.
format Online
Article
Text
id pubmed-8121110
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Jaypee Brothers Medical Publishing
record_format MEDLINE/PubMed
spelling pubmed-81211102021-05-20 Reducing the Risk of Ring Breakage in Taylor Spatial Frames: The Effect of Frame Configuration on Strain at the Half-ring Junction Iliadis, Alexios D Bebja, Roland Wang, Katherine Moazen, Mehran Wright, Jonathan Calder, Peter Goodier, David Strategies Trauma Limb Reconstr Original Article AIM: We have encountered four cases with Taylor spatial frames (TSF) (Smith & Nephew, Memphis, TN, USA) with breakage at the half-ring junction of the distal ring. This study examines the strain produced on different locations of the distal ring during loading and the effects on the strain of altering the frame construct. MATERIALS AND METHODS: We mounted two ring TSF constructs on tibia saw bone models. The proximal ring was the same in all constructs and consisted of a 2/3 180 mm ring attached with three wires. Construct 1 is reproducing the configuration of cases where failure was seen. The distal 155 mm ring is attached with three half pins. The half-ring junction is located in the midline. Construct 2 has a different half pin placement and an additional wire on the distal ring. Constructs 3 and 4 have the same half pin configuration to construct 1 but the distal ring is rotated 60° internally and externally, respectively. Strain gauges were attached to different locations and measurements recorded during loading. Statistical analysis was performed. RESULTS: Highest strain values were recorded at the half-ring junction of constructs 1 and 2 (>600 microstrains (με) in tension). Rotating the ring 60° internally significantly reduces the strain at the half-ring junction (<300 με) whilst external rotation by 60° further reduces the strain (<180 με). Ring strain is higher in areas close to half pin attachments. CONCLUSION: The highest strain is in the half-ring junction as the half rings are subjected to different loading modes. The thickness of the half-ring is halved and the second moment of area reduced further increasing breakage risk. Placing this junction close to the half pin–frame interface, as dictated by the anatomical safe zone further increases the strain. Rotating the distal ring 60° significantly reduces the strain at the half-ring junction. CLINICAL SIGNIFICANCE: Ring breakage is a rare but significant complication. This is the first study to address this potential mode of TSF failure. Insights and technical tips from this study can help reduce this. HOW TO CITE THIS ARTICLE: Iliadis AD, Bebja R, Wang K, et al. Reducing the Risk of Ring Breakage in Taylor Spatial Frames: The Effect of Frame Configuration on Strain at the Half-ring Junction. Strategies Trauma Limb Reconstr 2020;15(3):146–150. Jaypee Brothers Medical Publishing 2020 /pmc/articles/PMC8121110/ /pubmed/34025794 http://dx.doi.org/10.5005/jp-journals-10080-1508 Text en Copyright © 2020; Jaypee Brothers Medical Publishers (P) Ltd. https://creativecommons.org/licenses/by-nc/4.0/© Jaypee Brothers Medical Publishers. 2020 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted use, distribution, and non-commercial reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated.
spellingShingle Original Article
Iliadis, Alexios D
Bebja, Roland
Wang, Katherine
Moazen, Mehran
Wright, Jonathan
Calder, Peter
Goodier, David
Reducing the Risk of Ring Breakage in Taylor Spatial Frames: The Effect of Frame Configuration on Strain at the Half-ring Junction
title Reducing the Risk of Ring Breakage in Taylor Spatial Frames: The Effect of Frame Configuration on Strain at the Half-ring Junction
title_full Reducing the Risk of Ring Breakage in Taylor Spatial Frames: The Effect of Frame Configuration on Strain at the Half-ring Junction
title_fullStr Reducing the Risk of Ring Breakage in Taylor Spatial Frames: The Effect of Frame Configuration on Strain at the Half-ring Junction
title_full_unstemmed Reducing the Risk of Ring Breakage in Taylor Spatial Frames: The Effect of Frame Configuration on Strain at the Half-ring Junction
title_short Reducing the Risk of Ring Breakage in Taylor Spatial Frames: The Effect of Frame Configuration on Strain at the Half-ring Junction
title_sort reducing the risk of ring breakage in taylor spatial frames: the effect of frame configuration on strain at the half-ring junction
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8121110/
https://www.ncbi.nlm.nih.gov/pubmed/34025794
http://dx.doi.org/10.5005/jp-journals-10080-1508
work_keys_str_mv AT iliadisalexiosd reducingtheriskofringbreakageintaylorspatialframestheeffectofframeconfigurationonstrainatthehalfringjunction
AT bebjaroland reducingtheriskofringbreakageintaylorspatialframestheeffectofframeconfigurationonstrainatthehalfringjunction
AT wangkatherine reducingtheriskofringbreakageintaylorspatialframestheeffectofframeconfigurationonstrainatthehalfringjunction
AT moazenmehran reducingtheriskofringbreakageintaylorspatialframestheeffectofframeconfigurationonstrainatthehalfringjunction
AT wrightjonathan reducingtheriskofringbreakageintaylorspatialframestheeffectofframeconfigurationonstrainatthehalfringjunction
AT calderpeter reducingtheriskofringbreakageintaylorspatialframestheeffectofframeconfigurationonstrainatthehalfringjunction
AT goodierdavid reducingtheriskofringbreakageintaylorspatialframestheeffectofframeconfigurationonstrainatthehalfringjunction