Cargando…

Impact of selenium addition to the cadmium-zinc-telluride matrix for producing high energy resolution X-and gamma-ray detectors

Both material quality and detector performance have been steadily improving over the past few years for the leading room temperature radiation detector material cadmium-zinc-telluride (CdZnTe). However, although tremendous progress being made, CdZnTe still suffers from high concentrations of perform...

Descripción completa

Detalles Bibliográficos
Autores principales: Roy, Utpal N., Camarda, Giuseppe S., Cui, Yonggang, Yang, Ge, James, Ralph B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8121847/
https://www.ncbi.nlm.nih.gov/pubmed/33990654
http://dx.doi.org/10.1038/s41598-021-89795-z
_version_ 1783692465921851392
author Roy, Utpal N.
Camarda, Giuseppe S.
Cui, Yonggang
Yang, Ge
James, Ralph B.
author_facet Roy, Utpal N.
Camarda, Giuseppe S.
Cui, Yonggang
Yang, Ge
James, Ralph B.
author_sort Roy, Utpal N.
collection PubMed
description Both material quality and detector performance have been steadily improving over the past few years for the leading room temperature radiation detector material cadmium-zinc-telluride (CdZnTe). However, although tremendous progress being made, CdZnTe still suffers from high concentrations of performance-limiting defects, such as Te inclusions, networks of sub-grain boundaries and compositional inhomogeneity due to the higher segregation coefficient of Zn. Adding as low as 2% (atomic) Se into CdZnTe matrix was found to successfully mitigate many performance-limiting defects and provide improved compositional homogeneity. Here we report record-high performance of Virtual Frisch Grid (VFG) detector fabricated from as-grown Cd(0.9)Zn(0.1)Te(0.98)Se(0.02) ingot grown by the Traveling Heater Method (THM). Benefiting from superior material quality, we achieved superb energy resolution of 0.77% at 662 keV (as-measured without charge-loss correction algorithms) registered at room temperature. The absence of residual thermal stress in the detector was revealed from white beam X-ray topographic images, which was also confirmed by Infra-Red (IR) transmission imaging under cross polarizers. Furthermore, neither sub-grain boundaries nor their networks were observed from the X-ray topographic image. However, large concentrations of extrinsic impurities were revealed in as-grown materials, suggesting a high likelihood for further reduction in the energy resolution after improved purification of the starting material.
format Online
Article
Text
id pubmed-8121847
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-81218472021-05-17 Impact of selenium addition to the cadmium-zinc-telluride matrix for producing high energy resolution X-and gamma-ray detectors Roy, Utpal N. Camarda, Giuseppe S. Cui, Yonggang Yang, Ge James, Ralph B. Sci Rep Article Both material quality and detector performance have been steadily improving over the past few years for the leading room temperature radiation detector material cadmium-zinc-telluride (CdZnTe). However, although tremendous progress being made, CdZnTe still suffers from high concentrations of performance-limiting defects, such as Te inclusions, networks of sub-grain boundaries and compositional inhomogeneity due to the higher segregation coefficient of Zn. Adding as low as 2% (atomic) Se into CdZnTe matrix was found to successfully mitigate many performance-limiting defects and provide improved compositional homogeneity. Here we report record-high performance of Virtual Frisch Grid (VFG) detector fabricated from as-grown Cd(0.9)Zn(0.1)Te(0.98)Se(0.02) ingot grown by the Traveling Heater Method (THM). Benefiting from superior material quality, we achieved superb energy resolution of 0.77% at 662 keV (as-measured without charge-loss correction algorithms) registered at room temperature. The absence of residual thermal stress in the detector was revealed from white beam X-ray topographic images, which was also confirmed by Infra-Red (IR) transmission imaging under cross polarizers. Furthermore, neither sub-grain boundaries nor their networks were observed from the X-ray topographic image. However, large concentrations of extrinsic impurities were revealed in as-grown materials, suggesting a high likelihood for further reduction in the energy resolution after improved purification of the starting material. Nature Publishing Group UK 2021-05-14 /pmc/articles/PMC8121847/ /pubmed/33990654 http://dx.doi.org/10.1038/s41598-021-89795-z Text en © This is a U.S. Government work and not under copyright protection in the US; foreign copyright protection may apply 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Roy, Utpal N.
Camarda, Giuseppe S.
Cui, Yonggang
Yang, Ge
James, Ralph B.
Impact of selenium addition to the cadmium-zinc-telluride matrix for producing high energy resolution X-and gamma-ray detectors
title Impact of selenium addition to the cadmium-zinc-telluride matrix for producing high energy resolution X-and gamma-ray detectors
title_full Impact of selenium addition to the cadmium-zinc-telluride matrix for producing high energy resolution X-and gamma-ray detectors
title_fullStr Impact of selenium addition to the cadmium-zinc-telluride matrix for producing high energy resolution X-and gamma-ray detectors
title_full_unstemmed Impact of selenium addition to the cadmium-zinc-telluride matrix for producing high energy resolution X-and gamma-ray detectors
title_short Impact of selenium addition to the cadmium-zinc-telluride matrix for producing high energy resolution X-and gamma-ray detectors
title_sort impact of selenium addition to the cadmium-zinc-telluride matrix for producing high energy resolution x-and gamma-ray detectors
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8121847/
https://www.ncbi.nlm.nih.gov/pubmed/33990654
http://dx.doi.org/10.1038/s41598-021-89795-z
work_keys_str_mv AT royutpaln impactofseleniumadditiontothecadmiumzinctelluridematrixforproducinghighenergyresolutionxandgammaraydetectors
AT camardagiuseppes impactofseleniumadditiontothecadmiumzinctelluridematrixforproducinghighenergyresolutionxandgammaraydetectors
AT cuiyonggang impactofseleniumadditiontothecadmiumzinctelluridematrixforproducinghighenergyresolutionxandgammaraydetectors
AT yangge impactofseleniumadditiontothecadmiumzinctelluridematrixforproducinghighenergyresolutionxandgammaraydetectors
AT jamesralphb impactofseleniumadditiontothecadmiumzinctelluridematrixforproducinghighenergyresolutionxandgammaraydetectors