Cargando…

Stress distribution of esthetic posts in the restored maxillary central incisor: Three-dimensional finite-element analysis

BACKGROUND: Glass fiber posts, along with their esthetic properties, may have a better stress distribution than cast posts, Therefore, the aim of the present study was to investigate the effect of glass fiber, casting, titanium, and zirconia posts on stress distribution in maxillary central tooth tr...

Descripción completa

Detalles Bibliográficos
Autores principales: Jafari, Sina, Alihemmati, Mohammad, Ghomi, Ali Jamali, Shayegh, Sayed Shojaedin, Kargar, Kamran
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8122688/
https://www.ncbi.nlm.nih.gov/pubmed/34084297
_version_ 1783692686284292096
author Jafari, Sina
Alihemmati, Mohammad
Ghomi, Ali Jamali
Shayegh, Sayed Shojaedin
Kargar, Kamran
author_facet Jafari, Sina
Alihemmati, Mohammad
Ghomi, Ali Jamali
Shayegh, Sayed Shojaedin
Kargar, Kamran
author_sort Jafari, Sina
collection PubMed
description BACKGROUND: Glass fiber posts, along with their esthetic properties, may have a better stress distribution than cast posts, Therefore, the aim of the present study was to investigate the effect of glass fiber, casting, titanium, and zirconia posts on stress distribution in maxillary central tooth treated with different amounts of ferrule using finite-element analysis. MATERIALS AND METHODS: In this experimental study, three-dimensional models of maxillary central incisors that have undergone root canal treatment were designed. Then, the models were divided into four groups according to the type of post (Ni-Cr casting, glass fiber, titanium, and zirconia) used. Zirconia monolithic crowns were used in all the four groups. Ferrule heights were repeated at 0 and 2 mm in all models. Models were entered into COMSOL Metaphysics software. Then, the force of 100 N with the angle of 135° on the palatal surface was applied to the longitudinal axis of the tooth, and the stress distribution in the models was investigated. RESULTS: Maximum stress was observed in the middle third of posts. Stress distribution in glass fiber post was better than zirconia and casting posts. Stress accumulation in models with zirconia, titanium, and casting posts was also found in the site between the middle third and coronal third, whereas in models with glass fiber post, stress accumulation was found between the crown and the cemento-enamel junction. In models without ferrule, stress accumulation was observed in one-third of the coronal, especially in glass fiber posts. CONCLUSION: The post material and ferrule height affected stress concentration. The stress in the cervical area of the dentin was more for glass fiber post when compared to other posts. The use of glass fiber post in teeth with no ferrule results in lower stress along the post, but greater stress in the simulated tooth region.
format Online
Article
Text
id pubmed-8122688
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-81226882021-06-02 Stress distribution of esthetic posts in the restored maxillary central incisor: Three-dimensional finite-element analysis Jafari, Sina Alihemmati, Mohammad Ghomi, Ali Jamali Shayegh, Sayed Shojaedin Kargar, Kamran Dent Res J (Isfahan) Original Article BACKGROUND: Glass fiber posts, along with their esthetic properties, may have a better stress distribution than cast posts, Therefore, the aim of the present study was to investigate the effect of glass fiber, casting, titanium, and zirconia posts on stress distribution in maxillary central tooth treated with different amounts of ferrule using finite-element analysis. MATERIALS AND METHODS: In this experimental study, three-dimensional models of maxillary central incisors that have undergone root canal treatment were designed. Then, the models were divided into four groups according to the type of post (Ni-Cr casting, glass fiber, titanium, and zirconia) used. Zirconia monolithic crowns were used in all the four groups. Ferrule heights were repeated at 0 and 2 mm in all models. Models were entered into COMSOL Metaphysics software. Then, the force of 100 N with the angle of 135° on the palatal surface was applied to the longitudinal axis of the tooth, and the stress distribution in the models was investigated. RESULTS: Maximum stress was observed in the middle third of posts. Stress distribution in glass fiber post was better than zirconia and casting posts. Stress accumulation in models with zirconia, titanium, and casting posts was also found in the site between the middle third and coronal third, whereas in models with glass fiber post, stress accumulation was found between the crown and the cemento-enamel junction. In models without ferrule, stress accumulation was observed in one-third of the coronal, especially in glass fiber posts. CONCLUSION: The post material and ferrule height affected stress concentration. The stress in the cervical area of the dentin was more for glass fiber post when compared to other posts. The use of glass fiber post in teeth with no ferrule results in lower stress along the post, but greater stress in the simulated tooth region. Wolters Kluwer - Medknow 2021-02-23 /pmc/articles/PMC8122688/ /pubmed/34084297 Text en Copyright: © 2021 Dental Research Journal https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Jafari, Sina
Alihemmati, Mohammad
Ghomi, Ali Jamali
Shayegh, Sayed Shojaedin
Kargar, Kamran
Stress distribution of esthetic posts in the restored maxillary central incisor: Three-dimensional finite-element analysis
title Stress distribution of esthetic posts in the restored maxillary central incisor: Three-dimensional finite-element analysis
title_full Stress distribution of esthetic posts in the restored maxillary central incisor: Three-dimensional finite-element analysis
title_fullStr Stress distribution of esthetic posts in the restored maxillary central incisor: Three-dimensional finite-element analysis
title_full_unstemmed Stress distribution of esthetic posts in the restored maxillary central incisor: Three-dimensional finite-element analysis
title_short Stress distribution of esthetic posts in the restored maxillary central incisor: Three-dimensional finite-element analysis
title_sort stress distribution of esthetic posts in the restored maxillary central incisor: three-dimensional finite-element analysis
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8122688/
https://www.ncbi.nlm.nih.gov/pubmed/34084297
work_keys_str_mv AT jafarisina stressdistributionofestheticpostsintherestoredmaxillarycentralincisorthreedimensionalfiniteelementanalysis
AT alihemmatimohammad stressdistributionofestheticpostsintherestoredmaxillarycentralincisorthreedimensionalfiniteelementanalysis
AT ghomialijamali stressdistributionofestheticpostsintherestoredmaxillarycentralincisorthreedimensionalfiniteelementanalysis
AT shayeghsayedshojaedin stressdistributionofestheticpostsintherestoredmaxillarycentralincisorthreedimensionalfiniteelementanalysis
AT kargarkamran stressdistributionofestheticpostsintherestoredmaxillarycentralincisorthreedimensionalfiniteelementanalysis