Use of the Renal Artery Doppler to Identify Small for Gestational Age Fetuses at Risk for Adverse Neonatal Outcomes

Objective: To measure the sensitivity and positive predictive value (PPV) for an adverse neonatal outcome among growth-restricted fetuses (FGR) comparing the cerebral–placental ratio (CPR) with the cerebral–renal ratio (CRR). Methods: Retrospective analysis of 92 women who underwent prenatal ultraso...

Descripción completa

Detalles Bibliográficos
Autores principales: Contag, Stephen, Visentin, Silvia, Goetzinger, Katherine, Cosmi, Erich
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8122939/
https://www.ncbi.nlm.nih.gov/pubmed/33922550
http://dx.doi.org/10.3390/jcm10091835
Descripción
Sumario:Objective: To measure the sensitivity and positive predictive value (PPV) for an adverse neonatal outcome among growth-restricted fetuses (FGR) comparing the cerebral–placental ratio (CPR) with the cerebral–renal ratio (CRR). Methods: Retrospective analysis of 92 women who underwent prenatal ultrasound at the University of Maryland and the University of Padua. Renal, middle cerebral and umbilical artery Doppler waveforms were recorded for all scans during the third trimester. The last scan prior to delivery was included for analysis. We calculated the test characteristics of the pulsatility indices (PI) of the umbilical and renal arteries in addition to the derived CPR and CRR to detect a composite adverse neonatal outcome. Results: The test characteristics of the four Doppler ratios to detect increased risk for the composite neonatal outcome demonstrated that the umbilical artery pulsatility index had the best test performance (sensitivity 64% (95% CI: 47–82%), PPV 24% (95% CI: 21–27), and positive likelihood ratio 2.7 (95% CI: 1.4–5.2)). There was no benefit to using the CRR compared with the CPR. The agreement between tests was moderate to poor (Kappa value CPR compared with CRR: 0.5 (95%CI 0.4–0.70), renal artery PI:−0.1 (95% CI −0.2–0.0), umbilical artery PI: 0.5 (95% CI 0.4–0.7)). Only the umbilical artery had an area under the receiver operating curve that was significantly better compared with the CPR as a reference (p-value < 0.01). Conclusions: The data that we present do not support the use of renal artery Doppler as a useful clinical test to identify a fetus at risk for an adverse neonatal outcome. Within the various indices applied to this population, umbilical artery Doppler performed the best in identifying the fetuses at risk for an adverse perinatal outcome.