Cargando…
Tunneling Magnetoresistance DC Current Transformer for Ion Beam Diagnostics
In this paper, open loop and closed loop Tunneling Magnetoresistance (TMR) DC Current Transformers (DCCTs) for ion beam diagnostics are presented. The DCCTs employ MR sensors to measure the DC component of the accelerator’s ion beam. A comparative study between Giant Magnetoresistance (GMR) and TMR...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8123615/ https://www.ncbi.nlm.nih.gov/pubmed/33925289 http://dx.doi.org/10.3390/s21093043 |
_version_ | 1783692958967529472 |
---|---|
author | Azab, Eman Hegazy, Yasser G. Reeg, Hansjoerg Schwickert, Marcus Hofmann, Klaus |
author_facet | Azab, Eman Hegazy, Yasser G. Reeg, Hansjoerg Schwickert, Marcus Hofmann, Klaus |
author_sort | Azab, Eman |
collection | PubMed |
description | In this paper, open loop and closed loop Tunneling Magnetoresistance (TMR) DC Current Transformers (DCCTs) for ion beam diagnostics are presented. The DCCTs employ MR sensors to measure the DC component of the accelerator’s ion beam. A comparative study between Giant Magnetoresistance (GMR) and TMR sensors is presented to illustrate the sensor selection criterion for the DCCT application. The two proposed DCCTs are studied in open and closed loop configurations. A closed loop feedback electronic system is designed to generate a feedback current equivalent to the ion beam current such that the sensor operates at zero flux. Furthermore, theoretical and experimental results for the TMR-based DCCT including noise analysis are presented for both open loop and closed loop configurations. Both configurations’ minimum detectable currents are in the range of microampere. The proposed closed loop hardware prototype has a settling time of less than 15 μs. The measured minimum detectable currents for the open and closed loop TMR-based DCCTs are 128.2 μA/ [Formula: see text] and 10.14 μA/ [Formula: see text] at 1 Hz, respectively. |
format | Online Article Text |
id | pubmed-8123615 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-81236152021-05-16 Tunneling Magnetoresistance DC Current Transformer for Ion Beam Diagnostics Azab, Eman Hegazy, Yasser G. Reeg, Hansjoerg Schwickert, Marcus Hofmann, Klaus Sensors (Basel) Article In this paper, open loop and closed loop Tunneling Magnetoresistance (TMR) DC Current Transformers (DCCTs) for ion beam diagnostics are presented. The DCCTs employ MR sensors to measure the DC component of the accelerator’s ion beam. A comparative study between Giant Magnetoresistance (GMR) and TMR sensors is presented to illustrate the sensor selection criterion for the DCCT application. The two proposed DCCTs are studied in open and closed loop configurations. A closed loop feedback electronic system is designed to generate a feedback current equivalent to the ion beam current such that the sensor operates at zero flux. Furthermore, theoretical and experimental results for the TMR-based DCCT including noise analysis are presented for both open loop and closed loop configurations. Both configurations’ minimum detectable currents are in the range of microampere. The proposed closed loop hardware prototype has a settling time of less than 15 μs. The measured minimum detectable currents for the open and closed loop TMR-based DCCTs are 128.2 μA/ [Formula: see text] and 10.14 μA/ [Formula: see text] at 1 Hz, respectively. MDPI 2021-04-27 /pmc/articles/PMC8123615/ /pubmed/33925289 http://dx.doi.org/10.3390/s21093043 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Azab, Eman Hegazy, Yasser G. Reeg, Hansjoerg Schwickert, Marcus Hofmann, Klaus Tunneling Magnetoresistance DC Current Transformer for Ion Beam Diagnostics |
title | Tunneling Magnetoresistance DC Current Transformer for Ion Beam Diagnostics |
title_full | Tunneling Magnetoresistance DC Current Transformer for Ion Beam Diagnostics |
title_fullStr | Tunneling Magnetoresistance DC Current Transformer for Ion Beam Diagnostics |
title_full_unstemmed | Tunneling Magnetoresistance DC Current Transformer for Ion Beam Diagnostics |
title_short | Tunneling Magnetoresistance DC Current Transformer for Ion Beam Diagnostics |
title_sort | tunneling magnetoresistance dc current transformer for ion beam diagnostics |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8123615/ https://www.ncbi.nlm.nih.gov/pubmed/33925289 http://dx.doi.org/10.3390/s21093043 |
work_keys_str_mv | AT azabeman tunnelingmagnetoresistancedccurrenttransformerforionbeamdiagnostics AT hegazyyasserg tunnelingmagnetoresistancedccurrenttransformerforionbeamdiagnostics AT reeghansjoerg tunnelingmagnetoresistancedccurrenttransformerforionbeamdiagnostics AT schwickertmarcus tunnelingmagnetoresistancedccurrenttransformerforionbeamdiagnostics AT hofmannklaus tunnelingmagnetoresistancedccurrenttransformerforionbeamdiagnostics |