Cargando…

Tunneling Magnetoresistance DC Current Transformer for Ion Beam Diagnostics

In this paper, open loop and closed loop Tunneling Magnetoresistance (TMR) DC Current Transformers (DCCTs) for ion beam diagnostics are presented. The DCCTs employ MR sensors to measure the DC component of the accelerator’s ion beam. A comparative study between Giant Magnetoresistance (GMR) and TMR...

Descripción completa

Detalles Bibliográficos
Autores principales: Azab, Eman, Hegazy, Yasser G., Reeg, Hansjoerg, Schwickert, Marcus, Hofmann, Klaus
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8123615/
https://www.ncbi.nlm.nih.gov/pubmed/33925289
http://dx.doi.org/10.3390/s21093043
_version_ 1783692958967529472
author Azab, Eman
Hegazy, Yasser G.
Reeg, Hansjoerg
Schwickert, Marcus
Hofmann, Klaus
author_facet Azab, Eman
Hegazy, Yasser G.
Reeg, Hansjoerg
Schwickert, Marcus
Hofmann, Klaus
author_sort Azab, Eman
collection PubMed
description In this paper, open loop and closed loop Tunneling Magnetoresistance (TMR) DC Current Transformers (DCCTs) for ion beam diagnostics are presented. The DCCTs employ MR sensors to measure the DC component of the accelerator’s ion beam. A comparative study between Giant Magnetoresistance (GMR) and TMR sensors is presented to illustrate the sensor selection criterion for the DCCT application. The two proposed DCCTs are studied in open and closed loop configurations. A closed loop feedback electronic system is designed to generate a feedback current equivalent to the ion beam current such that the sensor operates at zero flux. Furthermore, theoretical and experimental results for the TMR-based DCCT including noise analysis are presented for both open loop and closed loop configurations. Both configurations’ minimum detectable currents are in the range of microampere. The proposed closed loop hardware prototype has a settling time of less than 15 μs. The measured minimum detectable currents for the open and closed loop TMR-based DCCTs are 128.2 μA/ [Formula: see text] and 10.14 μA/ [Formula: see text] at 1 Hz, respectively.
format Online
Article
Text
id pubmed-8123615
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-81236152021-05-16 Tunneling Magnetoresistance DC Current Transformer for Ion Beam Diagnostics Azab, Eman Hegazy, Yasser G. Reeg, Hansjoerg Schwickert, Marcus Hofmann, Klaus Sensors (Basel) Article In this paper, open loop and closed loop Tunneling Magnetoresistance (TMR) DC Current Transformers (DCCTs) for ion beam diagnostics are presented. The DCCTs employ MR sensors to measure the DC component of the accelerator’s ion beam. A comparative study between Giant Magnetoresistance (GMR) and TMR sensors is presented to illustrate the sensor selection criterion for the DCCT application. The two proposed DCCTs are studied in open and closed loop configurations. A closed loop feedback electronic system is designed to generate a feedback current equivalent to the ion beam current such that the sensor operates at zero flux. Furthermore, theoretical and experimental results for the TMR-based DCCT including noise analysis are presented for both open loop and closed loop configurations. Both configurations’ minimum detectable currents are in the range of microampere. The proposed closed loop hardware prototype has a settling time of less than 15 μs. The measured minimum detectable currents for the open and closed loop TMR-based DCCTs are 128.2 μA/ [Formula: see text] and 10.14 μA/ [Formula: see text] at 1 Hz, respectively. MDPI 2021-04-27 /pmc/articles/PMC8123615/ /pubmed/33925289 http://dx.doi.org/10.3390/s21093043 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Azab, Eman
Hegazy, Yasser G.
Reeg, Hansjoerg
Schwickert, Marcus
Hofmann, Klaus
Tunneling Magnetoresistance DC Current Transformer for Ion Beam Diagnostics
title Tunneling Magnetoresistance DC Current Transformer for Ion Beam Diagnostics
title_full Tunneling Magnetoresistance DC Current Transformer for Ion Beam Diagnostics
title_fullStr Tunneling Magnetoresistance DC Current Transformer for Ion Beam Diagnostics
title_full_unstemmed Tunneling Magnetoresistance DC Current Transformer for Ion Beam Diagnostics
title_short Tunneling Magnetoresistance DC Current Transformer for Ion Beam Diagnostics
title_sort tunneling magnetoresistance dc current transformer for ion beam diagnostics
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8123615/
https://www.ncbi.nlm.nih.gov/pubmed/33925289
http://dx.doi.org/10.3390/s21093043
work_keys_str_mv AT azabeman tunnelingmagnetoresistancedccurrenttransformerforionbeamdiagnostics
AT hegazyyasserg tunnelingmagnetoresistancedccurrenttransformerforionbeamdiagnostics
AT reeghansjoerg tunnelingmagnetoresistancedccurrenttransformerforionbeamdiagnostics
AT schwickertmarcus tunnelingmagnetoresistancedccurrenttransformerforionbeamdiagnostics
AT hofmannklaus tunnelingmagnetoresistancedccurrenttransformerforionbeamdiagnostics