Tunneling Magnetoresistance DC Current Transformer for Ion Beam Diagnostics
In this paper, open loop and closed loop Tunneling Magnetoresistance (TMR) DC Current Transformers (DCCTs) for ion beam diagnostics are presented. The DCCTs employ MR sensors to measure the DC component of the accelerator’s ion beam. A comparative study between Giant Magnetoresistance (GMR) and TMR...