Cargando…

Modeling and Experimental Characterization of Bonding Delaminations in Single-Element Ultrasonic Transducer

Ultrasonic transducers performance can be seriously deteriorated by loss of adhesion between some constitutive elements such as the active element, the backing, or the matching layer. In the present work, the influence of bonding delaminations on the performance of a single-element ultrasonic transd...

Descripción completa

Detalles Bibliográficos
Autores principales: Ding, Wenxiang, Bavencoffe, Maxime, Lethiecq, Marc
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8124843/
https://www.ncbi.nlm.nih.gov/pubmed/33925669
http://dx.doi.org/10.3390/ma14092269
_version_ 1783693327317598208
author Ding, Wenxiang
Bavencoffe, Maxime
Lethiecq, Marc
author_facet Ding, Wenxiang
Bavencoffe, Maxime
Lethiecq, Marc
author_sort Ding, Wenxiang
collection PubMed
description Ultrasonic transducers performance can be seriously deteriorated by loss of adhesion between some constitutive elements such as the active element, the backing, or the matching layer. In the present work, the influence of bonding delaminations on the performance of a single-element ultrasonic transducer, which is composed of a piezoelectric disk, a backing, and a matching layer, is studied numerically and experimentally. Based on the positions between layers, two cases, i.e., delaminations between ceramic and backing or between ceramic and matching layer, are considered. Each case involves three different types of delaminations, which are marked as delamination type (DT)-I, II, and III. DT-I, a circular shape delamination, starts from the center and expands towards the peripheric zone; DT-II, an annular shape delamination, starts from the peripheric zone and expands towards the center; DT-III is a sector shape delamination with a given angle. The numerical simulations are performed by the finite element method and the influence of delaminations on the electromechanical admittance (EMA) of the transducer is investigated. 3D printed backings and matching layers are mounted on a PZT sample to assemble delaminated single-element transducers. An impedance analyzer is used for experimental measurements. Comparison between numerical and experimental results shows a reasonable agreement making changes in EMA an interesting indicator to inform about the occurrence and severity of delaminations in a single-element ultrasonic transducer.
format Online
Article
Text
id pubmed-8124843
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-81248432021-05-17 Modeling and Experimental Characterization of Bonding Delaminations in Single-Element Ultrasonic Transducer Ding, Wenxiang Bavencoffe, Maxime Lethiecq, Marc Materials (Basel) Article Ultrasonic transducers performance can be seriously deteriorated by loss of adhesion between some constitutive elements such as the active element, the backing, or the matching layer. In the present work, the influence of bonding delaminations on the performance of a single-element ultrasonic transducer, which is composed of a piezoelectric disk, a backing, and a matching layer, is studied numerically and experimentally. Based on the positions between layers, two cases, i.e., delaminations between ceramic and backing or between ceramic and matching layer, are considered. Each case involves three different types of delaminations, which are marked as delamination type (DT)-I, II, and III. DT-I, a circular shape delamination, starts from the center and expands towards the peripheric zone; DT-II, an annular shape delamination, starts from the peripheric zone and expands towards the center; DT-III is a sector shape delamination with a given angle. The numerical simulations are performed by the finite element method and the influence of delaminations on the electromechanical admittance (EMA) of the transducer is investigated. 3D printed backings and matching layers are mounted on a PZT sample to assemble delaminated single-element transducers. An impedance analyzer is used for experimental measurements. Comparison between numerical and experimental results shows a reasonable agreement making changes in EMA an interesting indicator to inform about the occurrence and severity of delaminations in a single-element ultrasonic transducer. MDPI 2021-04-27 /pmc/articles/PMC8124843/ /pubmed/33925669 http://dx.doi.org/10.3390/ma14092269 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ding, Wenxiang
Bavencoffe, Maxime
Lethiecq, Marc
Modeling and Experimental Characterization of Bonding Delaminations in Single-Element Ultrasonic Transducer
title Modeling and Experimental Characterization of Bonding Delaminations in Single-Element Ultrasonic Transducer
title_full Modeling and Experimental Characterization of Bonding Delaminations in Single-Element Ultrasonic Transducer
title_fullStr Modeling and Experimental Characterization of Bonding Delaminations in Single-Element Ultrasonic Transducer
title_full_unstemmed Modeling and Experimental Characterization of Bonding Delaminations in Single-Element Ultrasonic Transducer
title_short Modeling and Experimental Characterization of Bonding Delaminations in Single-Element Ultrasonic Transducer
title_sort modeling and experimental characterization of bonding delaminations in single-element ultrasonic transducer
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8124843/
https://www.ncbi.nlm.nih.gov/pubmed/33925669
http://dx.doi.org/10.3390/ma14092269
work_keys_str_mv AT dingwenxiang modelingandexperimentalcharacterizationofbondingdelaminationsinsingleelementultrasonictransducer
AT bavencoffemaxime modelingandexperimentalcharacterizationofbondingdelaminationsinsingleelementultrasonictransducer
AT lethiecqmarc modelingandexperimentalcharacterizationofbondingdelaminationsinsingleelementultrasonictransducer