Cargando…

Autoencoder-Based Extrasystole Detection and Modification of RRI Data for Precise Heart Rate Variability Analysis

Heart rate variability, which is the fluctuation of the R-R interval (RRI) in electrocardiograms (ECG), has been widely adopted for autonomous evaluation. Since the HRV features that are extracted from RRI data easily fluctuate when arrhythmia occurs, RRI data with arrhythmia need to be modified app...

Descripción completa

Detalles Bibliográficos
Autores principales: Fujiwara, Koichi, Miyatani, Shota, Goda, Asuka, Miyajima, Miho, Sasano, Tetsuo, Kano, Manabu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8125061/
https://www.ncbi.nlm.nih.gov/pubmed/34067051
http://dx.doi.org/10.3390/s21093235
_version_ 1783693389349257216
author Fujiwara, Koichi
Miyatani, Shota
Goda, Asuka
Miyajima, Miho
Sasano, Tetsuo
Kano, Manabu
author_facet Fujiwara, Koichi
Miyatani, Shota
Goda, Asuka
Miyajima, Miho
Sasano, Tetsuo
Kano, Manabu
author_sort Fujiwara, Koichi
collection PubMed
description Heart rate variability, which is the fluctuation of the R-R interval (RRI) in electrocardiograms (ECG), has been widely adopted for autonomous evaluation. Since the HRV features that are extracted from RRI data easily fluctuate when arrhythmia occurs, RRI data with arrhythmia need to be modified appropriately before HRV analysis. In this study, we consider two types of extrasystoles—premature ventricular contraction (PVC) and premature atrial contraction (PAC)—which are types of extrasystoles that occur every day, even in healthy persons who have no cardiovascular diseases. A unified framework for ectopic RRI detection and a modification algorithm that utilizes an autoencoder (AE) type of neural network is proposed. The proposed framework consists of extrasystole occurrence detection from the RRI data and modification, whose targets are PVC and PAC. The RRI data are monitored by means of the AE in real time in the detection phase, and a denoising autoencoder (DAE) modifies the ectopic RRI caused by the detected extrasystole. These are referred to as AE-based extrasystole detection (AED) and DAE-based extrasystole modification (DAEM), respectively. The proposed framework was applied to real RRI data with PVC and PAC. The result showed that AED achieved a sensitivity of 93% and a false positive rate of 0.08 times per hour. The root mean squared error of the modified RRI decreased to 31% in PVC and 73% in PAC from the original RRI data by DAEM. In addition, the proposed framework was validated through application to a clinical epileptic seizure problem, which showed that it correctly suppressed the false positives caused by PVC. Thus, the proposed framework can contribute to realizing accurate HRV-based health monitoring and medical sensing systems.
format Online
Article
Text
id pubmed-8125061
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-81250612021-05-17 Autoencoder-Based Extrasystole Detection and Modification of RRI Data for Precise Heart Rate Variability Analysis Fujiwara, Koichi Miyatani, Shota Goda, Asuka Miyajima, Miho Sasano, Tetsuo Kano, Manabu Sensors (Basel) Article Heart rate variability, which is the fluctuation of the R-R interval (RRI) in electrocardiograms (ECG), has been widely adopted for autonomous evaluation. Since the HRV features that are extracted from RRI data easily fluctuate when arrhythmia occurs, RRI data with arrhythmia need to be modified appropriately before HRV analysis. In this study, we consider two types of extrasystoles—premature ventricular contraction (PVC) and premature atrial contraction (PAC)—which are types of extrasystoles that occur every day, even in healthy persons who have no cardiovascular diseases. A unified framework for ectopic RRI detection and a modification algorithm that utilizes an autoencoder (AE) type of neural network is proposed. The proposed framework consists of extrasystole occurrence detection from the RRI data and modification, whose targets are PVC and PAC. The RRI data are monitored by means of the AE in real time in the detection phase, and a denoising autoencoder (DAE) modifies the ectopic RRI caused by the detected extrasystole. These are referred to as AE-based extrasystole detection (AED) and DAE-based extrasystole modification (DAEM), respectively. The proposed framework was applied to real RRI data with PVC and PAC. The result showed that AED achieved a sensitivity of 93% and a false positive rate of 0.08 times per hour. The root mean squared error of the modified RRI decreased to 31% in PVC and 73% in PAC from the original RRI data by DAEM. In addition, the proposed framework was validated through application to a clinical epileptic seizure problem, which showed that it correctly suppressed the false positives caused by PVC. Thus, the proposed framework can contribute to realizing accurate HRV-based health monitoring and medical sensing systems. MDPI 2021-05-07 /pmc/articles/PMC8125061/ /pubmed/34067051 http://dx.doi.org/10.3390/s21093235 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Fujiwara, Koichi
Miyatani, Shota
Goda, Asuka
Miyajima, Miho
Sasano, Tetsuo
Kano, Manabu
Autoencoder-Based Extrasystole Detection and Modification of RRI Data for Precise Heart Rate Variability Analysis
title Autoencoder-Based Extrasystole Detection and Modification of RRI Data for Precise Heart Rate Variability Analysis
title_full Autoencoder-Based Extrasystole Detection and Modification of RRI Data for Precise Heart Rate Variability Analysis
title_fullStr Autoencoder-Based Extrasystole Detection and Modification of RRI Data for Precise Heart Rate Variability Analysis
title_full_unstemmed Autoencoder-Based Extrasystole Detection and Modification of RRI Data for Precise Heart Rate Variability Analysis
title_short Autoencoder-Based Extrasystole Detection and Modification of RRI Data for Precise Heart Rate Variability Analysis
title_sort autoencoder-based extrasystole detection and modification of rri data for precise heart rate variability analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8125061/
https://www.ncbi.nlm.nih.gov/pubmed/34067051
http://dx.doi.org/10.3390/s21093235
work_keys_str_mv AT fujiwarakoichi autoencoderbasedextrasystoledetectionandmodificationofrridataforpreciseheartratevariabilityanalysis
AT miyatanishota autoencoderbasedextrasystoledetectionandmodificationofrridataforpreciseheartratevariabilityanalysis
AT godaasuka autoencoderbasedextrasystoledetectionandmodificationofrridataforpreciseheartratevariabilityanalysis
AT miyajimamiho autoencoderbasedextrasystoledetectionandmodificationofrridataforpreciseheartratevariabilityanalysis
AT sasanotetsuo autoencoderbasedextrasystoledetectionandmodificationofrridataforpreciseheartratevariabilityanalysis
AT kanomanabu autoencoderbasedextrasystoledetectionandmodificationofrridataforpreciseheartratevariabilityanalysis