Cargando…
Polyvinyl Chloride Modified Carbon Paste Electrodes for Sensitive Determination of Levofloxacin Drug in Serum, Urine, and Pharmaceutical Formulations
Levofloxacin (LF) is a medically important antibiotic drug that is used to treat a variety of bacterial infections. In this study, three highly sensitive and selective carbon paste electrodes (CPEs) were fabricated for potentiometric determination of the LF drug: (i) CPEs filled with carbon paste (r...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8125218/ https://www.ncbi.nlm.nih.gov/pubmed/34062895 http://dx.doi.org/10.3390/s21093150 |
Sumario: | Levofloxacin (LF) is a medically important antibiotic drug that is used to treat a variety of bacterial infections. In this study, three highly sensitive and selective carbon paste electrodes (CPEs) were fabricated for potentiometric determination of the LF drug: (i) CPEs filled with carbon paste (referred to as CPE); (ii) CPE coated (drop-casted) with ion-selective PVC membrane (referred to as C-CPE); (iii) CPE filled with carbon paste modified with a plasticizer (PVC/cyclohexanone) (referenced as P-CPE). The CPE was formulated from graphite (Gr, 44.0%) and reduced graphene oxide (rGO, 3.0%) as the carbon source, tricresyl phosphate (TCP, 47.0%) as the plasticizer; sodium tetrakis[3,5-bis(trifluoromethyl)phenyl] borate (St-TFPMB, 1.0%) as the ion exchanger; and levofloxacinium-tetraphenylborate (LF-TPB, 5.0%) as the lipophilic ion pair. It showed a sub-Nernstian slope of 49.3 mV decade(−1) within the LF concentration range 1.0 × 10(−2) M to 1.0 × 10(−5) M, with a detection limit of 1.0 × 10(−5) M. The PVC coated electrode (C-CPE) showed improved sensitivity (in terms of slope, equal to 50.2 mV decade(−1)) compared to CPEs. After the incorporation of PVC paste on the modified CPE (P-CPE), the sensitivity increased at 53.5 mV decade(−1), indicating such improvement. The selectivity coefficient ([Formula: see text]) against different interfering species (Na(+), K(+), NH(4+), Ca(2+), Al(3+), Fe(3+), Glycine, Glucose, Maltose, Lactose) were significantly improved by one to three orders of magnitudes in the case of C-CPE and P-CPE, compared to CPEs. The modification with the PVC membrane coating significantly improved the response time and solubility of the LF-TPB within the electrode matrix and increased the lifetime. The constructed sensors were successfully applied for LF determination in pharmaceutical preparation (Levoxin(®) 500 mg), spiked urine, and serum samples with high accuracy and precision. |
---|